    Redesigning Solar Water Pumping System at Giricahyo, Gunungkidul Regency, Yogyakarta: HOMER Analysis Approach

    Get PDF
    HOMER, the software for micro-power applicable as renewable energy optimization, was used to analyze solar water pumping system based on deferrable-load and primary-load methods at Giricahyo. The 12 kWp solar PV and 30 kW generator were used to power the standing-aline system.. Unfortunately, the system has been idle since 2010. Research to redesign and analyse solar water pumping system has been conducted by Ministry of Public Works together with the Department of Physics Engineering UGM to bring it into normally. Furthermore, this study was aimed to obtain recommendation and to conduct analysis on system performance using HOMER. As a result in deferrable-load method, generator is inappropriate to be implemented because fossil fuel will be very expensive and rare. Besides, the 12 kWp Solar PV could meet 31.4 % of demand load. In primary-load method, capacity shortage of 1.5 kW pump is at 3.2 % and 3 kW pump is at 9.9 % which means that to deal with fluctuation of solar radiation the use of the 1.5 kW pumps were recommended. The demand that can be fulfilled by 1.5 kW pump is at 22.4 %. Keywords: capacity shortage; giricahyo; HOMER; redesign; solar water supply system

    ANALISIS PERANCANGAN KEMBALI SISTEM PENYEDIAAN AIR BERSIH DI DESA GIRICAHYO KECAMATAN PURWOSARI KABUPATEN GUNUNGKIDUL DI YOGYAKARTA BERBASIS HOMER

    No full text
    Water Supply System in Giricahyo Village was built in 2007. This system was powered from generator 30 kW and PV 12 kWp, but the system is stand alone and disjointed. Generator is used to drive 1 pump while PV pumps 10 submersible pumps and arranged in two pumping sistems with a total of head 235 m. Both of these systems did not work since 2010. Ministry of Public Work through Unit Department of PK-PAM Yogyakarta wants to repair the system back. In collaboration with the Department of Physics Engineering UGM, the research was conducted to evaluate and re design water supply system. This study specifically focused on re-design based on HOMER software. The result of this study is a recommendation and analysis sistem performed using HOMER. HOMER analyzes performance using deferrable and primary loads methods. This analysis sees how far the prospects of PV energy can be used as well as determines the optimal pump power that can be used by making variable of its pump. The result, 12 kWp PV needed converter 4 kW to meet the needs of optimum of 31.4 %. Pump load are 1.5 kW and 3 kW load used in the primary method analysis. As a result, capacity shortage of 1.5 kW is at 3.2 % and for 3 kW pump is at 9.9 % which means the use of pumps up to 1.5 kW is better and can deal with fluctuating solar radiation. The demand that can be fulfilled by 1.5 kW pump is at 22.4 % . The use of generators is not recommended
    corecore