16,743 research outputs found

    A Cavitation Susceptability Meter with Optical Cavitation Monitoring-Part One: Design Concepts

    Get PDF
    This work is concerned with the design of a Cavitation Susceptibility Meter based on the use of a venturi tube for the measurement of the active cavitation nuclei concentration in water samples as a function of the applied tension. The operation of the Cavitation Susceptibility Meter is analyzed and the main considerations leading to the proposed design are illustrated and critically discussed. The results of this analysis indicate that the operational range is mainly limited by nuclei interference, flow separation and saturation (choking), and suggest to develop a Cavitation Susceptibility Meter where; (1) the flow possesses a laminar potential core throughout the venturi throat section in all operational conditions; (b) the pressure at the venturi throat is determined from the upstream pressure and the local flow velocity; (c) the detection of cavitation and the measurement of the flow velocity are carried out optically by means of a Laser Doppler Velocimeter; (d) a custom-made electronic Signal Processor incorporating a frequency counter is used for real time data generation and temporary storage; (e) a computerized system performs the final acquisition and reduction of the data

    Separation and Surface Nuclei Effects in a Cavitation Susceptibility Meter

    Get PDF
    This work is concerned with the effects of flow separation and surface nuclei on the operation of a fixed geometry Cavitation Susceptibility Meter (CSM) with laminar flow. Cavitation is induced under controlled conditions at the throat of a glass venturi tube for the measurement of the active nuclei concentration in water samples as a function of the applied tension. Both cavitation and flow velocity are monitored optically by a Laser Doppler Velocimeter. The throat pressure is determined indirectly from the upstream pressure and the local flow velocity. The results show that laminar flow separation and surface nuclei effects are the most stringent operational limitations. Separation in the diffuser increases the minimum attainable throat pressure above the susceptibility of most cavitation nuclei commonly found in technical waters. Surface nuclei can generate extensive sheet or spot cavitation at relatively high tensions even on optically finished glass surfaces. These phenomena are difficult to eliminate and bring therefore into question the practical utility of CSM's with laminar flow and fixed geometry for the measurement of the dependence of the cavitating nuclei concentration over wide ranges of the applied tension, as required for cavitation studies

    A Cavitation Susceptibility Meter with Optical Cavitation Monitoring -- Part Two: Experimental Apparatus and Results

    Get PDF
    This work in concerned with the development and operation of a Cavitation Susceptibility Meter based on the use of a venturi tube for the measurement of the active cavitation nuclei concentration in water samples as a function of the applied tension. The pressure at the venturi throat is determined from the upstream pressure and the local flow velocity without corrections for viscous effects because the flow possesses a laminar potential core in all operational conditions. The detection of cavitation and the measurement of the flow velocity are carried out optically by means of a Laser Doppler Velocimeter. A custom-made electronic Signal Processor is used for real time data generation and temporary storage and a computerized system for final data acquisition and reduction. The implementation of the whole system is described and the results of the application of the Cavitation Susceptibility Meter to the measurement of the water quality of tap water samples are presented and critically discussed with reference to the current state of knowledge on cavitation inception

    Pasting and Reversing Approach to Matrix Theory

    Full text link
    The aim of this paper is to study some aspects of matrix theory through Pasting and Reversing. We start giving a summary of previous results concerning to Pasting and Reversing over vectors and matrices, after we rewrite such properties of Pasting and Reversing in matrix theory using linear mappings to finish with new properties and new sets in matrix theory involving Pasting and Reversing. In particular we introduce new linear mappings: Palindromicing and Antipalindromicing mappings, which allow us to obtain palindromic and antipalindromic vectors and matrices.Comment: 19 page

    An integrated model for computer assisted diagnosis, treatment and design of insoles for the diabetic foot

    Get PDF
    The incidence of diabetes has increased significantly in recent decades. In Germany, there is an estimate of three million diabetics and this number is growing at a rate of about 2 percent per year. In the U.S.A., the American Diabetes Association estimates that thirteen million people suffer from this condition, representing 5.2 percent of the entire population and every year, some 35 thousand patients have a lower limb amputated. In Latin America, it has been reported that the prevalence of diabetes is of the order of 14 to 20 percent, according to a research conducted by the WHO's Ad Hoc Diabetes Reporting Group. In Colombia, a study by Ashner et al concludes that the prevalence is 7 percent in both sexes
    • …
    corecore