41 research outputs found

    Are old running shoes detrimental to your feet? A pedobarographic study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Footwear characteristics have been implicated in fatigue and foot pain. The recommended time for changing running shoes is every 500 miles. The aim of our study was to assess and compare plantar peak pressures and pressure time integrals in new and old running shoes.</p> <p>Findings</p> <p>This was a prospective study involving 11 healthy female volunteers with no previous foot and ankle problems. New running shoes were provided to the participants. Plantar pressures were measured using the Novel Pedar system while walking with new and participants' personal old running shoes. Plantar pressures were measured in nine areas of the feet. Demographic data, age of old running shoes, Body Mass Index (BMI), peak pressures and pressure-time integral were acquired. The right and left feet were selected at random and assessed separately. Statistical analysis was done using the paired t test to compare measurements between old and new running shoes.</p> <p>The mean peak pressures were higher in new running shoes (330.5 ± 79.6 kiloPascals kPa) when compared to used old running shoes (304 ± 58.1 kPa) (p = 0.01). The pressure-time integral was significantly higher in the new running shoes (110 ± 28.3 kPa s) compared to used old running shoes (100.7 ± 24.0 kPa s) (p = 0.01).</p> <p>Conclusion</p> <p>Plantar pressure measurements in general were higher in new running shoes. This could be due to the lack of flexibility in new running shoes. The risk of injury to the foot and ankle would appear to be higher if running shoes are changed frequently. We recommend breaking into new running shoes slowly using them for mild physical activity.</p

    Athlete and coach perceptions of technology needs for evaluating running performance

    Get PDF
    This article was published in the journal, Sports Enginnering [Springer Verlag / © International Sports Engineering Association]. The definitive version is available at: http://dx.doi.org/10.1007/s12283-010-0049-9Athletes and their support team utilise technology to measure and evaluate technique and athletic performance. Existing techniques for motion and propulsion measurement and analysis include a combination of indirect methods (high-speed video) and direct methods (force plates and pressure systems). These methods are predominantly limited to controlled laboratory environments (in a small area relative to the competition environment), require expert advice and support, and can take significant time to evaluate the data. Consequently, the more advanced measurement techniques are considered to be restricted to specific coaching sessions, or periods in the year leading up to competition, when the time and expertise of further support staff are available. The more widely used, and simple, devices for monitoring 'performance' during running include stopwatches, GPS tracking and accelerometer-based systems to count strides. These provide useful information on running duration, distance and velocity but lack detailed information on many key aspects of running technique. In order to begin the process of development of more innovative technologies for routine use by athletes and coaches, a study was required to improve the understanding of athletes' and coaches' perception of their requirements from measurement technology. This study outlines a systematic approach to elicit and evaluate their perceptions, and presents the findings from interviews and a questionnaire. The qualitative data are presented as a hierarchical graphical plot (structured relationship model) showing six general dimensions (technique, footwear and surface, environment, performance, injury and cardiovascular) and shows the development of these general dimensions from the interviewee quotations. The questionnaire quantitative data enhances the study by further ranking characteristics that arise from the interviews. A contrast is shown between short and longer distance runner groups, as might be expected. The current technology available to elite runners is briefly reviewed in relation to the 22 characteristics identified as important to measure. The conclusions highlight the need for newer technologies to measure aspects of running style and performance in a portable and integrated manner, with suggestions as to size and weight likely to be acceptable to users for emerging devices. © 2010 International Sports Engineering Association

    Movement of the human foot in 100 pain free individuals aged 18–45 : implications for understanding normal foot function

    Get PDF
    Background: Understanding motion in the normal healthy foot is a prerequisite for understanding the effects of pathology and thereafter setting targets for interventions. Quality foot kinematic data from healthy feet will also assist the development of high quality and research based clinical models of foot biomechanics. To address gaps in the current literature we aimed to describe 3D foot kinematics using a 5 segment foot model in a population of 100 pain free individuals. Methods: Kinematics of the leg, calcaneus, midfoot, medial and lateral forefoot and hallux were measured in 100 self reported healthy and pain free individuals during walking. Descriptive statistics were used to characterise foot movements. Contributions from different foot segments to the total motion in each plane were also derived to explore functional roles of different parts of the foot. Results: Foot segments demonstrated greatest motion in the sagittal plane, but large ranges of movement in all planes. All foot segments demonstrated movement throughout gait, though least motion was observed between the midfoot and calcaneus. There was inconsistent evidence of movement coupling between joints. There were clear differences in motion data compared to foot segment models reported in the literature. Conclusions: The data reveal the foot is a multiarticular structure, movements are complex, show incomplete evidence of coupling, and vary person to person. The data provide a useful reference data set against which future experimental data can be compared and may provide the basis for conceptual models of foot function based on data rather than anecdotal observations

    Treatment of forefoot problems in older people: study protocol for a randomised clinical trial comparing podiatric treatment to standardised shoe advice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Foot problems in general and forefoot problems in particular can lead to a decrease in mobility and a higher risk of falling. Forefoot problems increase with age and are more common in women than in men. Around 20% of people over 65 suffer from non-traumatic foot problems and 60% of these problems are localised in the forefoot. Little is known about the best way to treat forefoot problems in older people. The aim of this study is to compare the effects of two common modes of treatment in the Netherlands: shoe advice and podiatric treatment. This paper describes the design of this study.</p> <p>Methods</p> <p>The study is designed as a pragmatic randomised clinical trial (RCT) with 2 parallel intervention groups. People aged 50 years and over who have visited their general practitioner (GP) with non traumatic pain in the forefoot in the preceding year and those who will visit their GP during the recruitment period with a similar complaint will be recruited for this study. Participants must be able to walk unaided for 7 metres and be able to fill in questionnaires. Exclusion criteria are: rheumatoid arthritis, neuropathy of the foot or pain caused by skin problems (e.g. warts, eczema). Inclusion and exclusion criteria will be assessed by a screening questionnaire and baseline assessment. Those consenting to participation will be randomly assigned to either a group receiving a standardised shoe advice leaflet (n = 100) or a group receiving podiatric treatment (n = 100). Primary outcomes will be the severity of forefoot pain (0-10 on a numerical rating scale) and foot function (Foot Function 5-pts Index and Manchester Foot Pain and Disability Index). Treatment adherence, social participation and quality of life will be the secondary outcomes. All outcomes will be obtained through self-administered questionnaires at the start of the study and after 3, 6, 9 and 12 months. Data will be analysed according to the "intention-to-treat" principle using multilevel level analysis.</p> <p>Discussion</p> <p>Strength of this study is the comparison between two common primary care treatments for forefoot problems, ensuring a high external validity of this trial.</p> <p>Trial registration</p> <p>Netherlands Trial Register (NTR): <a href="http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2212">NTR2212</a></p

    FCC-ee: The Lepton Collider: Future Circular Collider Conceptual Design Report Volume 2

    Get PDF
    In response to the 2013 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) study was launched, as an international collaboration hosted by CERN. This study covers a highest-luminosity high-energy lepton collider (FCC-ee) and an energy-frontier hadron collider (FCC-hh), which could, successively, be installed in the same 100 km tunnel. The scientific capabilities of the integrated FCC programme would serve the worldwide community throughout the 21st century. The FCC study also investigates an LHC energy upgrade, using FCC-hh technology. This document constitutes the second volume of the FCC Conceptual Design Report, devoted to the electron-positron collider FCC-ee. After summarizing the physics discovery opportunities, it presents the accelerator design, performance reach, a staged operation scenario, the underlying technologies, civil engineering, technical infrastructure, and an implementation plan. FCC-ee can be built with today’s technology. Most of the FCC-ee infrastructure could be reused for FCC-hh. Combining concepts from past and present lepton colliders and adding a few novel elements, the FCC-ee design promises outstandingly high luminosity. This will make the FCC-ee a unique precision instrument to study the heaviest known particles (Z, W and H bosons and the top quark), offering great direct and indirect sensitivity to new physics

    FCC Physics Opportunities: Future Circular Collider Conceptual Design Report Volume 1

    Get PDF
    We review the physics opportunities of the Future Circular Collider, covering its e+e-, pp, ep and heavy ion programmes. We describe the measurement capabilities of each FCC component, addressing the study of electroweak, Higgs and strong interactions, the top quark and flavour, as well as phenomena beyond the Standard Model. We highlight the synergy and complementarity of the different colliders, which will contribute to a uniquely coherent and ambitious research programme, providing an unmatchable combination of precision and sensitivity to new physics
    corecore