30 research outputs found
Serological monitoring of antibodies for an early diagnosis ofaspergillosis in captive penguins
Abstract: This study aimed to evaluate the efficacy of detection of anti-Aspergillus fumigatus antibodies in captive penguins by double radial agar gel immunodiffusion (AGID) for the aspergillosis diagnosis. We included 134 Magellanic penguins (Spheniscus magellanicus) in rehabilitation at the Center for Recovery of Marine Animals (CRAM / FURG). All of them were monitored by AGID weekly until its final destination (death or release), totalizing 660 serum samples studied. All animals were clinically accompanied and post-mortem examinations was performed in penguins that died during the studied period. A total of 28% (37/134) of the penguins died, 89.2% (33/37) due to aspergillosis, 11% (4/37) by other causes and 97 were released. From the 33 animals with proven aspergillosis, 21 presented anti- A. fumigatus antibodies by AGID, being the average interval between death and positive AGID 16.4 days. Twelve animals with negative serology died of aspergillosis. The sensitivity and specificity rates were 63.6% and 95% respectively, and the positive and negative predictive values were 80.7% and 88.9% respectively. These data demonstrate that the serological monitoring for detection of antibodies by AGID can be an important tool for the diagnosis of aspergillosis in penguins
Ziele, Moeglichkeiten und Grenzen computerunterstuetzter landwirtschaftlicher Betriebserhebungen in Entwicklungslaendern Eine kritische Analyse dargestellt am Beispiel des Erhebungssystems FARMAP der FAO
Bibliothek Weltwirtschaft Kiel A 172427 / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDEGerman
The theory of ultrasonic vibration potential imaging
The ultrasonic vibraton potential refers to the production of a time varying
voltage when ultrasound passes through a colloidal or ionic solution. The
vibration potential can be used as an imaging method for soft tissue by
recording its phase, time of arrival, and magnitude relative to the
launching of a burst of ultrasound. A theory of the effect can be found
from Maxwell's equations. Experimental results demonstrating the imaging
method are shown for bodies with simple geometries
Recommended from our members
Thin dielectric film thickness determination by advanced transmission electron microscopy
High Resolution Transmission Electron Microscopy (HR-TEM) has been used as the ultimate method of thickness measurement for thin films. The appearance of phase contrast interference patterns in HR-TEM images has long been confused as the appearance of a crystal lattice by non-specialists. Relatively easy to interpret crystal lattice images are now directly observed with the introduction of annular dark field detectors for scanning TEM (STEM). With the recent development of reliable lattice image processing software that creates crystal structure images from phase contrast data, HR-TEM can also provide crystal lattice images. The resolution of both methods was steadily improved reaching now into the sub Angstrom region. Improvements in electron lens and image analysis software are increasing the spatial resolution of both methods. Optimum resolution for STEM requires that the probe beam be highly localized. In STEM, beam localization is enhanced by selection of the correct aperture. When STEM measurement is done using a highly localized probe beam, HR-TEM and STEM measurement of the thickness of silicon oxynitride films agree within experimental error. In this paper, the optimum conditions for HR-TEM and STEM measurement are discussed along with a method for repeatable film thickness determination. The impact of sample thickness is also discussed. The key result in this paper is the proposal of a reproducible method for film thickness determination
Recommended from our members
Thin dielectric film thickness determination by advanced transmission electron microscopy
High Resolution Transmission Electron Microscopy (HR-TEM) has been used as the ultimate method of thickness measurement for thin films. The appearance of phase contrast interference patterns in HR-TEM images has long been confused as the appearance of a crystal lattice by non-specialists. Relatively easy to interpret crystal lattice images are now directly observed with the introduction of annular dark field detectors for scanning TEM (STEM). With the recent development of reliable lattice image processing software that creates crystal structure images from phase contrast data, HR-TEM can also provide crystal lattice images. The resolution of both methods was steadily improved reaching now into the sub Angstrom region. Improvements in electron lens and image analysis software are increasing the spatial resolution of both methods. Optimum resolution for STEM requires that the probe beam be highly localized. In STEM, beam localization is enhanced by selection of the correct aperture. When STEM measurement is done using a highly localized probe beam, HR-TEM and STEM measurement of the thickness of silicon oxynitride films agree within experimental error. In this paper, the optimum conditions for HR-TEM and STEM measurement are discussed along with a method for repeatable film thickness determination. The impact of sample thickness is also discussed. The key result in this paper is the proposal of a reproducible method for film thickness determination
Recommended from our members
Thin dielectric film thickness determination by advanced transmission electron microscopy
High Resolution Transmission Electron Microscopy (HR-TEM) has been used as the ultimate method of thickness measurement for thin films. The appearance of phase contrast interference patterns in HR-TEM images has long been confused as the appearance of a crystal lattice by non-specialists. Relatively easy to interpret crystal lattice images are now directly observed with the introduction of annular dark field detectors for scanning TEM (STEM). With the recent development of reliable lattice image processing software that creates crystal structure images from phase contrast data, HR-TEM can also provide crystal lattice images. The resolution of both methods was steadily improved reaching now into the sub Angstrom region. Improvements in electron lens and image analysis software are increasing the spatial resolution of both methods. Optimum resolution for STEM requires that the probe beam be highly localized. In STEM, beam localization is enhanced by selection of the correct aperture. When STEM measurement is done using a highly localized probe beam, HR-TEM and STEM measurement of the thickness of silicon oxynitride films agree within experimental error. In this paper, the optimum conditions for HR-TEM and STEM measurement are discussed along with a method for repeatable film thickness determination. The impact of sample thickness is also discussed. The key result in this paper is the proposal of a reproducible method for film thickness determination