23 research outputs found

    Stress final element analysis at the abatement-implant-bone interface

    No full text
    UNLABELLED: According to a researchAIM: we carried out the comparative final element analysis of stress in implant construction and the bone surrounding it. The best result showed implants with platform switching and cone interface between implant and abatement. Such combination of elements allows maintaining implant construction stability and decrease the load on cortical bone.Abstract available from the publisher

    Конечно-элементный математический анализ распределения нагрузки в системе "абатмент-имплантат-кость"

    No full text
    UNLABELLED: According to a researchAIM: we carried out the comparative final element analysis of stress in implant construction and the bone surrounding it. The best result showed implants with platform switching and cone interface between implant and abatement. Such combination of elements allows maintaining implant construction stability and decrease the load on cortical bone.Abstract available from the publisher.В соответствии с целью исследования мы провели сравнительный конечно-элементный анализ напряженно-деформированного состояния сборной конструкции имплантата и окружающей его кости. Оптимальной можно считать конструкцию имплантата с «переключением платформы» и узлом сопряжения в виде конуса, так как такое сочетание элементов позволяет сохранить прочность конструкции и снизить нагрузку на кортикальную кость

    Rigottotomy and lipofilling in the treatment of post-burn deformations in children: our experience

    Get PDF
    Actuality: rigottotomy and lipofillingis a method of surgical correction of post-burn deformities and scars. Rigottotomy increases the area of the reconstructed segment, which in the future, when performing lipofilling, allows to restore the contours and volume. The purpose of the study: evaluation of the advantages of this method compared to classical surgical operations. Patients and methods: we evaluated the results of treatment of 25 children with post-traumatic deformities and post burn scars and deformities of various localization. The stages of surgical correction: the first stage - the actual liposuction (tumescent). The second stage (primary) - preparing a donor bed to transplant fat cells. Implementation of rigottotomy (formation of channels crossing the scarred tissue in different planes) which are filled with lipoaspirates.The third stage – subcutaneous and/ or intradermal injection oflipografts to fill the volume with contour deformities. Patients divided into groups: the first group is about 10 children with a contoured deformation (post-burn and post-traumatic). The treatment was performed in several stages (at least 3). The first step is to fill no more than 20-30% of the area of the defect. For surgical correction of patients of this group were mainly used fat grafting. The second group of 9 children with hypertrophic scars and contractures of large joints. First stage is aggressive rigottotomy and subsequent intradermal injection of litografts to correct contractures. The third group is a group of 6 children with post-burn scars, violations of the structural composition of the skin. All patients have necessitated the 1-2 stages of lipofilling in combination with rigottotomy that helped to improve the quality of the skin and partly to eliminate cosmetic defect. All patients have received a good cosmetic and functional result. There were not any complications. Conclusion: advantages of this technique are: reducing the time of hospitalization; elimination of cosmetic defects and deformities; formation and recovery of the subcutaneous fat layer; improve the elasticity of the skin

    РЕЗУЛЬТАТЫ НЕПОСРЕДСТВЕННОЙ ДЕНТАЛЬНОЙ ИМПЛАНТАЦИИ С НЕМЕДЛЕННОЙ НАГРУЗКОЙ И ОБОСНОВАНИЕ ПРОТОКОЛА МЕТОДОМ МАТЕМАТИЧЕСКОГО МОДЕЛИРОВАНИЯ

    No full text
    The mathematical modeling of occlusal load distribution around implants of the Innovative Russian Implantation System (IRIS) with various forms of threads was conducted: the first implant model had an unshaped 0,3 mm thread (IRIS LIKO-M implant), the second model had a pronounced aggressive thread 0,8 mm high (implant of IRIS Evolution). Besides, were evaluated the five-year recalls of prosthetics on implants IRIS Evolution, installed immediately after the extraction of teeth with immediate prosthetics. The results showed that the equivalent von Mises distribution around the implants of IRIS Evolution were 3,9 MPa, around the IRIS LICO-M - 5,6 MPa, which is 31% higher. The differences can be explained by the larger surface area and the threaded part of the IRIS Evolution implant, namely 240,44 mm2 versus 158,27 mm2 in IRIS LICO-M. The maximum value of the deformation around the implant IRIS Evolution was 1,8 μm, around the IRIS LIKO-M - 2 μm. Thus, it is possible to note a decrease in the difference in the displacement of implants, which is explained by the absence of a «cohesion» between the implants and the bone tissue provided with osseointegration. The performed qualitative analysis ofthe opening of the gap at the bone-implant interface showed that the IRIS Evolution system has a general gap opening less than the IRIS LIKO system. This is also due to the greater surface area of IRIS Evolution. The results confirm the hypothesis that implants with aggressive threads are less mobile due to greater adhesion to the surrounding bone. According to the clinical study results, the level of cervical resorption after 5 years after prosthetics was 0,505 mm. The success of immediate post-extraction implant placement was 98,57% (3 lost of 201 installed), which is comparable to the Thus, immediate post-extraction implant placement with or without a loading procedure has become a predictable treatment for restoring the teeth in any clinical situation.В данном исследовании проводилось математическое моделирование распределения окклюзионной нагрузки вокруг имплантатов инновационной российской имплантационной системы ИРИС с различной формой резьбы: первая модель имплантата имела невыраженную резьбу высотой 0,3 мм (имплантат ИРИС ЛИКО-М), вторая модель имела выраженную агрессивную резьбу высотой 0,8 мм (имплантат ИРИС Эволюшн). А также оценивались пятилетние результаты протезирования на имплантатах ИРИС Эволюшн, установленных непосредственно после удаления зубов с немедленным протезированием. В результате проведенных исследований эквивалентные напряжения по Мизесу вокруг имплантатов ИРИС Эво-люшн составили 3,9 МПа, вокруг ИРИС ЛИКО-М - 5,6 Мпа, что на 31% выше. Различия в полученных данных можно объяснить большей площадью поверхности и резьбовой части имплантата ИРИС Эволюшн, а именно 240,44 мм2 против 158,27 мм.2 у ИРИС ЛИКО-М. Вокруг имплантата ИРИС Эволюшн максимальное значение деформации составило 1,8 мкм, вокруг ИРИС ЛИКО-М - 2 мкм. Таким образом, можно отметить снижение разницы в смещении имплантатов, что объясняется отсутствием «сцепления» между имплантатами и костной тканью, обеспеченным остеоинтеграцией. Выполненный качественный анализ раскрытия зазора на границе раздела кость-имплантат показал, что у системы ИРИС Эволюшн общее раскрытие зазора меньше, чем у системы ИРИС ЛИКО. Это также обусловлено большей площадью поверхности ИРИС Эво-люшн. Полученные результаты подтверждают предположения, что имплантаты с агрессивной резьбой менее подвижны благодаря большему сцеплению с окружающей костью. По результатам проведенной клинической части исследования уровень пришеечной резорбции через 5 лет после протезирования составил 0,505 мм. Выживаемость имплантатов при непосредственной установке составила 98,57% (потеряно 3 из 201 установленных), что сопоставимо с классической двухэтапной имплантацией. Таким образом, непосредственная имплантация с нагрузкой или без неё стала предсказуемым методом лечения для восстановления зубов в любых клинических ситуациях
    corecore