17,601 research outputs found
Miniature modular microwave end-to-end receiver
An end-to-end microwave receiver system contained in a single miniature hybrid package mounted on a single heatsink is presented. It includes an input end connected to a microwave receiver antenna and an output end which produces a digital count proportional to the amplitude of a signal of a selected microwave frequency band received at the antenna and corresponding to one of the water vapor absorption lines near frequencies of 20 GHz or 30 GHz. The hybrid package is on the order of several centimeters in length and a few centimeters in height and width. The package includes an L-shaped carrier having a base surface, a vertical wall extending up from the base surface and forming a corner therewith, and connection pins extending through the vertical wall. Modular blocks rest on the base surface against the vertical wall and support microwave monolithic integrated circuits on top surfaces thereof connected to the external connection pins. The modular blocks lie end-to-end on the base surface so as to be modularly removable by sliding along the base surface beneath the external connection pins away from the vertical wall
Monolithic microwave integrated circuit water vapor radiometer
A proof of concept Monolithic Microwave Integrated Circuit (MMIC) Water Vapor Radiometer (WVR) is under development at the Jet Propulsion Laboratory (JPL). WVR's are used to remotely sense water vapor and cloud liquid water in the atmosphere and are valuable for meteorological applications as well as for determination of signal path delays due to water vapor in the atmosphere. The high cost and large size of existing WVR instruments motivate the development of miniature MMIC WVR's, which have great potential for low cost mass production. The miniaturization of WVR components allows large scale deployment of WVR's for Earth environment and meteorological applications. Small WVR's can also result in improved thermal stability, resulting in improved calibration stability. Described here is the design and fabrication of a 31.4 GHz MMIC radiometer as one channel of a thermally stable WVR as a means of assessing MMIC technology feasibility
Disordered Electrons in a Strong Magnetic Field: Transfer Matrix Approaches to the Statistics of the Local Density of States
We present two novel approaches to establish the local density of states as
an order parameter field for the Anderson transition problem. We first
demonstrate for 2D quantum Hall systems the validity of conformal scaling
relations which are characteristic of order parameter fields. Second we show
the equivalence between the critical statistics of eigenvectors of the
Hamiltonian and of the transfer matrix, respectively. Based on this equivalence
we obtain the order parameter exponent for 3D quantum
Hall systems.Comment: 4 pages, 3 Postscript figures, corrected scale in Fig.
Risk factors for ischemic stroke and transient ischemic attack in patients under age 50
To analyze risk factors for ischemic stroke and transient ischemic attack (TIA) in young adults under the age of 50. To make recommendations for additional research and practical consequences. From 97 patients with ischemic stroke or TIA under the age of 50, classical cardiovascular risk factors, coagulation disorders, history of migraine, use of oral contraceptives, cardiac abnormalities on ECG and echocardiography, and the results of duplex ultrasound were retrospectively analyzed. Literature was reviewed and compared to the results. 56.4% of the patients had hypertension, 12.1% increased total cholesterol, 20% hypertriglyceridemia, 31.5% an increased LDL-level, 32.6% a decreased HDL-level and 7.2% a disturbed glucose tolerance. Thrombophilia investigation was abnormal in 21 patients and auto-immune serology was abnormal in 15 patients. Ten of these patients were already known with a systemic disease associated with an increased risk for ischemic stroke (i.e. systemic lupus erythematosus). The ECG was abnormal in 16.7% of the cases, the echocardiography in 12.1% and duplex ultrasound of the carotid arteries was in 31.8% of the cases abnormal. Conventional cardiovascular risk factors are not only important in patients over the age of 50 with ischemic stroke or TIA, but also in this younger population under the age of 50. Thrombophilia investigation and/ or autoimmune serology should be restricted to patients without conventional cardiovascular risk factors and a history or other clinical symptoms associated with hypercoagulability and/ or autoimmune diseases
Pattern measurements of a low-sidelobe horn antenna
The techniques and results of power pattern measurements of a corrugated horn antenna designed for low sidelobes are reported. The power pattern was measured to levels 90 dB below the main beam maximum in both the E- and H-planes. The measured patterns were found to be in good agreement with predictions from existing theory for the performance of corrugated scalar feeds
X-ray Observations of XSS J12270-4859 in a New Low State: A Transformation to a Disk-Free Rotation-Powered Pulsar Binary
We present XMM-Newton and Chandra observations of the low-mass X-ray binary
XSS J12270--4859, which experienced a dramatic decline in optical/X-ray
brightness at the end of 2012, indicative of the disappearance of its accretion
disk. In this new state, the system exhibits previously absent
orbital-phase-dependent, large-amplitude X-ray modulations with a decline in
flux at superior conjunction. The X-ray emission remains predominantly
non-thermal but with an order of magnitude lower mean luminosity and
significantly harder spectrum relative to the previous high flux state. This
phenomenology is identical to the behavior of the radio millisecond pulsar
binary PSR J1023+0038 in the absence of an accretion disk, where the X-ray
emission is produced in an intra-binary shock driven by the pulsar wind. This
further demonstrates that XSS J12270-4859 no longer has an accretion disk and
has transformed to a full-fledged eclipsing "redback" system that hosts an
active rotation-powered millisecond pulsar. There is no evidence for diffuse
X-ray emission associated with the binary that may arise due to outflows or a
wind nebula. An extended source situated 1.5' from XSS J12270--4859 is unlikely
to be associated, and is probably a previously uncatalogued galaxy cluster.Comment: 8 pages, 6 figures; accepted for publication in the Astrophysical
Journa
A small sealed Ta crucible for thermal analysis of volatile metallic samples
Differential thermal analysis on metallic alloys containing volatile elements
can be highly problematic. Here we show how measurements can be performed in
commercial, small-sample, equipment without modification. This is achieved by
using a sealed Ta crucible, easily fabricated from Ta tubing and sealed in a
standard arc furnace. The crucible performance is demonstrated by measurements
on a mixture of Mg and MgB, after heating up to 1470. We
also show data, measured on an alloy with composition GdMg, that
clearly shows both the liquidus and a peritectic, and is consistent with
published phase diagram data
Instabilities in the nonsymmetric theory of gravitation
We consider the linearized nonsymmetric theory of gravitation (NGT) within
the background of an expanding universe and near a Schwarzschild metric. We
show that the theory always develops instabilities unless the linearized
nonsymmetric lagrangian reduces to a particular simple form. This theory
contains a gauge invariant kinetic term, a mass term for the antisymmetric
metric-field and a coupling with the Ricci curvature scalar. This form cannot
be obtained within NGT. Next we discuss NGT beyond linearized level and
conjecture that the instabilities are not a relic of the linearization, but are
a general feature of the full theory. Finally we show that one cannot add
ad-hoc constraints to remove the instabilities as is possible with the
instabilities found in NGT by Clayton.Comment: 29 page
- …