7 research outputs found

    Town Of Great Barrington, Massachusetts Annual Reports For The Fiscal Year 2016 July 1, 2015 to June 30, 2016

    Get PDF
    SABRE (Sodium-iodide with Active Background REjection) is a direct dark matter search experiment based on an array of radio-pure NaI(Tl) crystals surrounded by a liquid scintillator veto. Twin SABRE experiments in the Northern and Southern Hemispheres will differentiate a dark matter signal from seasonal and local effects. The experiment is currently in a Proof-of-Principle (PoP) phase, whose goal is to demonstrate that the background rate is low enough to carry out an independent search for a dark matter signal, with sufficient sensitivity to confirm or refute the DAMA result during the following full-scale experimental phase. The impact of background radiation from the detector materials and the experimental site needs to be carefully investigated, including both intrinsic and cosmogenically activated radioactivity. Based on the best knowledge of the most relevant sources of background, we have performed a detailed Monte Carlo study evaluating the expected background in the dark matter search spectral region. The simulation model described in this paper guides the design of the full-scale experiment and will be fundamental for the interpretation of the measured background and hence for the extraction of a possible dark matter signal

    Heavy metal pathways and archives in biological tissue

    Full text link
    Nuclear milli and microprobes at the Australian Nuclear Science and Technology Organisation (ANSTO) were used to determine lead accumulation in native Australian plants and animals. Three species of eucalypt plants (Eucalyptus camaldulensis, Eucalyptus globulus and Eucalyptus lesouefii), one species of salt bush (Atriplex burbhanyana) and one species each of acacia (Acacia saligna) and estuarine crocodiles (Crocodylus porosus) were investigated. Experimentally grown plants were subjected to a nutrient solution with a pH of 5 and spiked with a 200 lmol concentration of Pb. Lead concentrations in leaves of both E. globulus and E. camaldulensis showed an almost exponential decrease from the base of the main vein to the tip. Similarly, Pb concentrations decreased from the main vein to secondary veins. Concentrations of essential elements such as K, Fe, Zn and Br in the main and secondary veins were constant within experimental uncertainty. In contrast, the concentrations of Pb in the leaf veins of E. lesouefii were much lower and showed no systematic pattern. In stem and root samples the highest concentration of Pb was found in roots and stem of E. globulus and A. burbhanyana followed by E. camaldulensis. Some Pb was found in roots of A. saligna and only very low concentration in stem of the same plant. More detailed analysis of thin cross-sectional samples of roots and stem showed that Pb is present in much higher concentration in the growth area of the plant structure (i.e. meristemic region) and in relatively low concentration within the pith region and outer cortex. The osteoderms (dermal bones) of estuarine crocodiles, exposed to lead ammunition in food from the hunting activities of traditional Aboriginal owners, were sampled at two sites in Kakadu National Park, northern Australia. PIXE analyses showed enhanced, but relatively constant, ratios of Pb/Ca in the annual laminations

    High-purity CdMnTe radiation detectors: a high-resolution spectroscopic evaluation

    No full text
    The charge transport properties of a high-purity CdMnTe (CMT) crystal have been measured at room temperature down to a micron-scale resolution. The CMT crystal, doped with indium, was grown by the vertical Bridgman technique. To reduce the residual impurities in the Mn source material, the growth process incorporated a five-times purification process of MnTe by a zone-refining method with molten Te solvent. The resulting 2.6 mm thick crystal exhibited an electron mobility-lifetime product of μnτn=2.9 × 10-3 cm2V-1. The velocity of electron drift was calculated from the rise time distribution of the preamplifier's output pulses at each measured bias. The electron mobility was extracted from the electric field dependence of the drift velocity and at room temperature it has a value of μn=(950±90) cm2/Vs. High-resolution maps of the charge collection efficiency have been measured using a scanning microbeam of 5.5 MeV 4He2+ ions focused to a beam diameter <; 1 μm and display large-area spatial uniformity. The evolution of charge collection uniformity across the detector has been highlighted by acquiring measurements at applied biases ranging between 50 V and 1100 V. Charge transport inhomogeneity has been associated with the presence of bulk defects. It has been demonstrated that minimizing the content of impurities in the MnTe source material is highly effective in achieving major improvements in the CMT detector's performance as compared to previous data. © 2013, IEEE

    Charge transport properties of CdMnTe radiation detectors

    No full text
    Growth, fabrication and characterization of indium-doped cadmium manganese telluride (CdMnTe) radiation detectors have been described. Alpha-particle spectroscopy measurements and time resolved current transient measurements have yielded an average charge collection efficiency approaching 100 %. Spatially resolved charge collection efficiency maps have been produced for a range of detector bias voltages. Inhomogeneities in the charge transport of the CdMnTe crystals have been associated with chains of tellurium inclusions within the detector bulk. Further, it has been shown that the role of tellurium inclusions in degrading charge collection is reduced with increasing values of bias voltage. The electron drift velocity was calculated from the rise time distribution of the preamplifier output pulses at each measured bias. From the dependence of drift velocity on applied electric field the electron mobility was found to be μn = (718 ± 55) cm2/Vs at room temperature

    Charge transport properties of CdMnTe radiation detectors

    No full text
    Growth, fabrication and characterization of indium-doped cadmium manganese telluride (CdMnTe)radiation detectors have been described. Alpha-particle spectroscopy measurements and time resolved current transient measurements have yielded an average charge collection efficiency approaching 100 %. Spatially resolved charge collection efficiency maps have been produced for a range of detector bias voltages. Inhomogeneities in the charge transport of the CdMnTe crystals have been associated with chains of tellurium inclusions within the detector bulk. Further, it has been shown that the role of tellurium inclusions in degrading chargecollection is reduced with increasing values of bias voltage. The electron transit time was determined from time of flight measurements. From the dependence of drift velocity on applied electric field the electron mobility was found to be n = (718 55) cm2/Vs at room temperature

    Town Of Ludlow, Massachusetts 2015 Annual Town Report

    Get PDF
    SABRE aims to directly measure the annual modulation of the dark matter interaction rate with NaI(Tl) crystals. A modulation compatible with the standard hypothesis, in which our Galaxy is immersed in a dark matter halo, has been measured by the DAMA experiment in the same target material. Other direct detection experiments, using different target materials, seem to exclude the interpretation of such modulation in the simplest scenario of WIMP-nucleon elastic scattering. The SABRE experiment aims to carry out an independent search with sufficient sensitivity to confirm or refute the DAMA claim. The goal of the SABRE experiment is to achieve the lowest background rate for a NaI(Tl) experiment (order of 0.1 cpd/kg/keVee in the energy region of interest for dark matter). This challenging goal could be achievable by operating high-purity crystals inside a liquid scintillator veto for active background rejection. In addition, twin detectors will be located in the northern and southern hemispheres to identify possible contributions to the modulation from seasonal or site-related effects. The SABRE project includes an initial Proof-of-Principle phase at LNGS (Italy), to assess the radio-purity of the crystals and the efficiency of the liquid scintillator veto. This paper describes the general concept of SABRE and the expected sensitivity to WIMP annual modulation
    corecore