542 research outputs found

    Direct reduction of pellets through hydrogen: Experimental and model behaviour

    Get PDF
    This paper presents the hydrogen reduction behaviour of industrial pellets designed for the efficient hydrogen based direct reduction. The pellets were provided with very low non ferrous oxides percentage (0.52 of basicity index) and with the absence on TiO2 oxides. The pellets measured diameters in the range 1.14–1.72 cm and were characterized in terms of porosity, pores size, tortuosity and compression strength. The pellets were reduced in hydrogen atmosphere in a laboratory shaft furnace in the temperature ranges of 600–1200 °C at the pressures of 1 and 5 bar. The pellets' reduction behaviour was analysed in terms of time to reduction, rate of reduction and kinetics constant. All the obtained results were analysed through the employment of a commercial multi-objective optimization tool (modeFrontier) in order to precisely define the effect of each single parameter on the pellets’ reduction. It was also defined the effect of the ongoing reduction rate of the final metallization of the starting iron oxides

    Determination of Odor Detection Threshold in the Göttingen Minipig

    Get PDF
    The aim of the study was to examine the ability of Göttingen minipigs to acquire an olfaction-based operant conditioning task and to determine the detection threshold for ethyl acetate and ethanol. We used an automated olfactometer developed for rodents to train and test 14 pigs. Odor sampling and reliable responding were obtained after three to fifteen 160-trial sessions. Successful transfer of the task from ethyl acetate to ethanol was achieved in 1–4 sessions. Detection threshold for ethyl acetate varied between 10−2% and 10−6% v/v and for ethanol between 0.1% and 5 × 10−6% v/v. The results provide evidence that minipigs can successfully acquire 2-odorant discrimination using a food-rewarded instrumental conditioning paradigm for testing olfactory function. This olfactory discrimination paradigm provides reliable measures of olfactory sensitivity and thereby enables detection of changes in olfaction in a porcine model of Alzheimer's disease currently being developed

    Quantization and Compressive Sensing

    Get PDF
    Quantization is an essential step in digitizing signals, and, therefore, an indispensable component of any modern acquisition system. This book chapter explores the interaction of quantization and compressive sensing and examines practical quantization strategies for compressive acquisition systems. Specifically, we first provide a brief overview of quantization and examine fundamental performance bounds applicable to any quantization approach. Next, we consider several forms of scalar quantizers, namely uniform, non-uniform, and 1-bit. We provide performance bounds and fundamental analysis, as well as practical quantizer designs and reconstruction algorithms that account for quantization. Furthermore, we provide an overview of Sigma-Delta (ΣΔ\Sigma\Delta) quantization in the compressed sensing context, and also discuss implementation issues, recovery algorithms and performance bounds. As we demonstrate, proper accounting for quantization and careful quantizer design has significant impact in the performance of a compressive acquisition system.Comment: 35 pages, 20 figures, to appear in Springer book "Compressed Sensing and Its Applications", 201

    Randomized assessment of imatinib in patients with acute ischaemic stroke treated with intravenous thrombolysis

    Full text link
    BackgroundImatinib, a tyrosine kinase inhibitor, has been shown to restore bloodâ brain barrier integrity and reduce infarct size, haemorrhagic transformation and cerebral oedema in stroke models treated with tissue plasminogen activator. We evaluated the safety of imatinib, based on clinical and neuroradiological data, and its potential influence on neurological and functional outcomes.MethodsA phase II randomized trial was performed in patients with acute ischaemic stroke treated with intravenous thrombolysis. A total of 60 patients were randomly assigned to four groups [3 (active): 1 (control)]; the active treatment groups received oral imatinib for 6 days at three dose levels (400, 600 and 800 mg). Primary outcome was any adverse event; secondary outcomes were haemorrhagic transformation, cerebral oedema, neurological severity on the National Institutes of Health Stroke Scale (NIHSS) at 7 days and at 3 months and functional outcomes on the modified Rankin scale (mRS).ResultsFour serious adverse events were reported, which resulted in three deaths (one in the control group and two in the 400â mg dose group; one patient in the latter group did not receive active treatment and the other received two doses). Nonserious adverse events were mostly mild, resulting in full recovery. Imatinib ameliorated neurological outcomes with an improvement of 0.6 NIHSS points per 100 mg imatinib (P = 0.02). For the 800â mg group, the mean unadjusted and adjusted NIHSS improvements were 4 (P = 0.037) and 5 points (P = 0.012), respectively, versus controls. Functional independence (mRS 0â 2) increased by 18% versus controls (61 vs. 79; P = 0.296).ConclusionThis phase II study showed that imatinib is safe and tolerable and may reduce neurological disability in patients treated with intravenous thrombolysis after ischaemic stroke. A confirmatory randomized trial is currently underway.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/136298/1/joim12576_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/136298/2/joim12576.pd

    Laser ablation loading of a radiofrequency ion trap

    Full text link
    The production of ions via laser ablation for the loading of radiofrequency (RF) ion traps is investigated using a nitrogen laser with a maximum pulse energy of 0.17 mJ and a peak intensity of about 250 MW/cm^2. A time-of-flight mass spectrometer is used to measure the ion yield and the distribution of the charge states. Singly charged ions of elements that are presently considered for the use in optical clocks or quantum logic applications could be produced from metallic samples at a rate of the order of magnitude 10^5 ions per pulse. A linear Paul trap was loaded with Th+ ions produced by laser ablation. An overall ion production and trapping efficiency of 10^-7 to 10^-6 was attained. For ions injected individually, a dependence of the capture probability on the phase of the RF field has been predicted. In the experiment this was not observed, presumably because of collective effects within the ablation plume.Comment: submitted to Appl. Phys. B., special issue on ion trappin

    The influence of an intense laser beam interaction with preformed plasma on the characteristics of emitted ion streams

    Get PDF
    AbstractIntense laser-beam interactions with preformed plasma, preceding the laser-target interactions, significantly influence both the ion and X-ray generation. It is due to the laser pulse (its total length, the shape of the front edge, its background, the contrast, the radial homogeneity) as well as plasma (density, temperature) properties. Generation of the super fast (FF) ion groups is connected with a presence of non-linear processes. Saturated maximum of the charge states (independently on the laser intensity) is ascribed to the constant limit radius of the self-focused laser beam. Its longitudinal structure is considered as a possible explanation for the course of some experimental dependencies obtained

    Characterization of an Enantioselective Odorant Receptor in the Yellow Fever Mosquito Aedes aegypti

    Get PDF
    Enantiomers differ only in the left or right handedness (chirality) of their orientations and exhibit identical chemical and physical properties. In chemical communication systems, enantiomers can be differentially active at the physiological and behavioral levels. Only recently were enantioselective odorant receptors demonstrated in mammals while their existence in insects has remained hypothetical. Using the two-microelectrode voltage clamp of Xenopus oocytes, we show that the yellow fever mosquito, Aedes aegypti, odorant receptor 8 (AaOR8) acts as a chiral selective receptor for the (R)-(—)-enantiomer of 1-octen-3-ol, which in the presence of other kairomones is an attractant used by blood-sucking insects to locate their hosts. In addition to steric constraints, chain length and degree of unsaturation play important roles in this recognition process. This is the first characterization of an enantioselective odorant receptor in insects and the results demonstrate that an OR alone, without helper proteins, can account for chiral specificity exhibited by olfactory sensory neurons (OSNs)

    Using the Barthel Index and modified Rankin Scale as outcome measures for stroke rehabilitation trials; A comparison of minimum sample size requirements

    Get PDF
    Objectives Underpowered trials risk inaccurate results. Recruitment to stroke rehabilitation randomised controlled trials (RCTs) is often a challenge. Statistical simulations offer an important opportunity to explore the adequacy of sample sizes in the context of specific outcome measures. We aimed to examine and compare the adequacy of stroke rehabilitation RCT sample sizes using the Barthel Index (BI) or modified Rankin Scale (mRS) as primary outcomes. Methods We conducted computer simulations using typical experimental event rates (EER) and control event rates (CER) based on individual participant data (IPD) from stroke rehabilitation RCTs. Event rates are the proportion of participants who experienced clinically relevant improvements in the RCT experimental and control groups. We examined minimum sample size requirements and estimated the number of participants required to achieve a number needed to treat within clinically acceptable boundaries for the BI and mRS. Results We secured 2350 IPD (18 RCTs). For a 90% chance of statistical accuracy on the BI a rehabilitation RCT would require 273 participants per randomised group. Accurate interpretation of effect sizes would require 1000s of participants per group. Simulations for the mRS were not possible as a clinically relevant improvement was not detected when using this outcome measure. Conclusions Stroke rehabilitation RCTs with large sample sizes are required for accurate interpretation of effect sizes based on the BI. The mRS lacked sensitivity to detect change and thus may be unsuitable as a primary outcome in stroke rehabilitation trials
    corecore