36,533 research outputs found

    Can the WIMP annihilation boost factor be boosted by the Sommerfeld enhancement?

    Get PDF
    We demonstrate that the Sommerfeld correction to CDM annihilations can be appreciable if even a small component of the dark matter is extremely cold. Subhalo substructure provides such a possibility given that the smallest clumps are relatively cold and contain even colder substructure due to incomplete phase space mixing. Leptonic channels can be enhanced for plausible models and the solar neighbourhood boost required to account for PAMELA/ATIC data is plausibly obtained, especially in the case of a few TeV mass neutralino for which the Sommerfeld-corrected boost is found to be 104105.\sim10^4-10^5. Saturation of the Sommerfeld effect is shown to occur below β104,\beta\sim 10^{-4}, thereby constraining the range of contributing substructures to be above 105M.\sim 10^5\rm M_\odot. We find that the associated diffuse gamma ray signal from annihilations would exceed EGRET constraints unless the channels annihilating to heavy quarks or to gauge bosons are suppressed. The lepton channel gamma rays are potentially detectable by the FERMI satellite, not from the inner galaxy where substructures are tidally disrupted, but rather as a quasi-isotropic background from the outer halo, unless the outer substructures are much less concentrated than the inner substructures and/or the CDM density profile out to the virial radius steepens significantly.Comment: 8 pages, 5 figures. References added. Replaced to match published versio

    ICI optical data storage tape

    Get PDF
    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Flexible optical media offers many benefits in terms of manufacture; for a given capital investment, continuous, web-coating techniques produce more square meters of media than batch coating. The coated layers consist of a backcoat on the non-active side; on the active side there is a subbing layer, then reflector, dye/polymer, and transparent protective overcoat. All these layers have been tailored for ease of manufacture and specific functional characteristics

    ICI optical data storage tape

    Get PDF
    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed

    Posterior Cervical Spine Crisscross Fixation: Biomechanical Evaluation

    Get PDF
    Background Biomechanical/anatomic limitations may limit the successful implantation, maintenance, and risk acceptance of posterior cervical plate/rod fixation for one stage decompression-fusion. A method of posterior fixation (crisscross) that resolves biomechanical deficiencies of previous facet wiring techniques and not reliant upon screw implantation has been devised. The biomechanical performance of the new method of facet fixation was compared to the traditional lateral mass plate/screw fixation method. Methods Thirteen human cadaver spine segments (C2-T1) were tested under flexion-compression loading and four were evaluated additionally under pure-moment load. Preparations were evaluated in a sequence of surgical alterations with intact, laminectomy, lateral mass plate/screw fixation, and crisscross facet fixation using forces, displacements and kinematics. Findings Combined loading demonstrated significantly lower bending stiffness (p \u3c 0.05) between laminectomy compared to crisscross and lateral mass plate/screw preparations. Crisscross fixation showed a comparative tendency for increased stiffness. The increased overall motion induced by laminectomy was resolved by both fixation techniques, with crisscross fixation demonstrating a comparatively more uniform change in segmental motions. Interpretation The crisscross technique of facet fixation offers immediate mechanical stability with resolution of increased flexural rotations induced by multi-level laminectomy. Many of the anatomic limitations and potentially deleterious variables that may be associated with multi-level screw fixation are not associated with facet wire passage, and the subsequent fixation using a pattern of wire connection crossing each facet joint exhibits a comparatively more uniform load distribution. Crisscross wire fixation is a valuable addition to the surgical armamentarium for extensive posterior cervical single-stage decompression-fixation

    The mode 3 crack problem in bonded materials with a nonhomogeneous interfacial zone

    Get PDF
    The mode 3 crack problem for two bonded homogeneous half planes was considered. The interfacial zone was modelled by a nonhomogeneous strip in such a way that the shear modulus is a continuous function throughout the composite medium and has discontinuous derivatives along the boundaries of the interfacial zone. The problem was formulated for cracks perpendicular to the nominal interface and was solved for various crack locations in and around the interfacial region. The asymptotic stress field near the tip of a crack terminating at an interface was examined and it was shown that, unlike the corresponding stress field in piecewise homogeneous materials, in this case the stresses have the standard square root singularity and their angular variation was identical to that of a crack in a homogeneous medium. With application to the subcritical crack growth process in mind, the results given include mostly the stress intensity factors for some typical crack geometries and various material combinations

    The crack problem in bonded nonhomogeneous materials

    Get PDF
    The plane elasticity problem for two bonded half planes containing a crack perpendicular to the interface was considered. The effect of very steep variations in the material properties near the diffusion plane on the singular behavior of the stresses and stress intensity factors were studied. The two materials were thus, assumed to have the shear moduli mu(o) and mu(o) exp (Beta x), x=0 being the diffusion plane. Of particular interest was the examination of the nature of stress singularity near a crack tip terminating at the interface where the shear modulus has a discontinuous derivative. The results show that, unlike the crack problem in piecewise homogeneous materials for which the singularity is of the form r/alpha, 0 less than alpha less than 1, in this problem the stresses have a standard square-root singularity regardless of the location of the crack tip. The nonhomogeneity constant Beta has, however, considerable influence on the stress intensity factors

    Evaluating Descriptive Metrics of the Human Cone Mosaic

    Get PDF
    Purpose: To evaluate how metrics used to describe the cone mosaic change in response to simulated photoreceptor undersampling (i.e., cell loss or misidentification). Methods: Using an adaptive optics ophthalmoscope, we acquired images of the cone mosaic from the center of fixation to 10° along the temporal, superior, inferior, and nasal meridians in 20 healthy subjects. Regions of interest (n = 1780) were extracted at regular intervals along each meridian. Cone mosaic geometry was assessed using a variety of metrics − density, density recovery profile distance (DRPD), nearest neighbor distance (NND), intercell distance (ICD), farthest neighbor distance (FND), percentage of six-sided Voronoi cells, nearest neighbor regularity (NNR), number of neighbors regularity (NoNR), and Voronoi cell area regularity (VCAR). The “performance” of each metric was evaluated by determining the level of simulated loss necessary to obtain 80% statistical power. Results: Of the metrics assessed, NND and DRPD were the least sensitive to undersampling, classifying mosaics that lost 50% of their coordinates as indistinguishable from normal. The NoNR was the most sensitive, detecting a significant deviation from normal with only a 10% cell loss. Conclusions: The robustness of cone spacing metrics makes them unsuitable for reliably detecting small deviations from normal or for tracking small changes in the mosaic over time. In contrast, regularity metrics are more sensitive to diffuse loss and, therefore, better suited for detecting such changes, provided the fraction of misidentified cells is minimal. Combining metrics with a variety of sensitivities may provide a more complete picture of the integrity of the photoreceptor mosaic
    corecore