17,339 research outputs found

    A simple reactive-transport model of calcite precipitation in soils and other porous media

    Get PDF
    Calcite formation in soils and other porous media generally occurs around a localised source of reactants, such as a plant root or soil macro-pore, and the rate depends on the transport of reactants to and from the precipitation zone as well as the kinetics of the precipitation reaction itself. However most studies are made in well mixed systems, in which such transport limitations are largely removed. We developed a mathematical model of calcite precipitation near a source of base in soil, allowing for transport limitations and precipitation kinetics. We tested the model against experimentally-determined rates of calcite precipitation and reactant concentration–distance profiles in columns of soil in contact with a layer of HCO3−-saturated exchange resin. The model parameter values were determined independently. The agreement between observed and predicted results was satisfactory given experimental limitations, indicating that the model correctly describes the important processes. A sensitivity analysis showed that all model parameters are important, indicating a simpler treatment would be inadequate. The sensitivity analysis showed that the amount of calcite precipitated and the spread of the precipitation zone were sensitive to parameters controlling rates of reactant transport (soil moisture content, salt content, pH, pH buffer power and CO2 pressure), as well as to the precipitation rate constant. We illustrate practical applications of the model with two examples: pH changes and CaCO3 precipitation in the soil around a plant root, and around a soil macro-pore containing a source of base such as urea

    Failure of non-vacuum steam sterilization processes for dental handpieces

    Get PDF
    Background: Dental handpieces are used in critical and semi-critical operative interventions. Although a number of dental professional bodies recommend that dental handpieces are sterilized between patient use there is a lack of clarity and understanding of the effectiveness of different steam sterilization processes. The internal mechanisms of dental handpieces contain narrow lumens (0·8-2·3mm) which can impede the removal of air and ingress of saturated steam required to achieve sterilization conditions. Aim: To identify the extent of sterilization failure in dental handpieces using a non-vacuum process. Methods: In-vitro and in-vivo investigations were conducted on commonly used UK benchtop steam sterilizers and three different types of dental handpieces. The sterilization process was monitored inside the lumens of dental handpieces using thermometric (TM) methods (dataloggers), chemical indicators (CI) and biological indicators (BI). Findings: All three methods of assessing achievement of sterility within dental handpieces that had been exposed to non-vacuum sterilization conditions demonstrated a significant number of failures (CI=8/3,024(fails/n tests); BI=15/3,024; TM=56/56) compared to vacuum sterilization conditions (CI=2/1,944; BI=0/1,944; TM=0/36). The dental handpiece most likely to fail sterilization in the non-vacuum process was the surgical handpiece. Non-vacuum sterilizers located in general dental practice had a higher rate of sterilization failure (CI=25/1,620; BI=32/1,620; TM=56/56) with no failures in vacuum process. Conclusion: Non-vacuum downward/gravity displacement, type-N steam sterilizers are an unreliable method for sterilization of dental handpieces in general dental practice. The handpiece most likely to fail sterilization is the type most frequently used for surgical interventions

    Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes

    Get PDF
    Background: Dental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices, are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organisations still advocate non-vacuum sterilization processes for these devices. Aim: To investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations. Methods: Measurements at different positions within air turbines were undertaken with thermocouples and dataloggers. Two examples of commonly used UK benchtop steam sterilizers were tested; a non-vacuum benchtop sterilizer (Little Sister 3, Eschmann, UK) and a vacuum benchtop sterilizer (Lisa, W&H, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate. Findings: A total of 140 measurements inside dental handpiece lumens were recorded. We demonstrate that the non-vacuum process fails (time range 0-150 seconds) to reliably achieve sterilization temperatures within the time limit specified by the International standard (15 seconds equilibration time). The measurement point at the base of the handpiece failed in all test runs (n=9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases. Conclusion: Non-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces and the base of the handpiece is the site most likely to fail

    Self-consistent models for Coulomb heated X-ray pulsar atmospheres

    Get PDF
    Calculations of accreting magnetized neutron star atmospheres heated by the gradual deceleration of protons via Coulomb collisions are presented. Self consistent determinations of the temperature and density structure for different accretion rates are made by assuming hydrostatic equilibrium and energy balance, coupled with radiative transfer. The full radiative transfer in two polarizations, using magnetic cross sections but with cyclotron resonance effects treated approximately, is carried out in the inhomogeneous atmospheres

    Sociology, Science and Sustainability: Developing Relationships in Scotland

    Get PDF
    This paper considers the application of the sociological imagination during the analysis of data collected during an ethnographic study of an environmental regulator, the Scottish Environment Protection Agency (SEPA). SEPA is tasked with implementing the European Water Framework Directive (WFD) in Scotland, which will radically alter the regulation of water use. Applying a sociological imagination allowed the researcher to advocate for a more interdisciplinary and equitable understanding of sustainable water use when feeding back initial research results at the end of the data collection period. The researchers introduced socialised definitions of the environment, which linked social justice and ecological concerns. These insights provided a challenge to the traditional bio-physical science focus of the organisational participants, for whom sustainability is a relatively new addition to their duties. The paper concludes by discussing the importance of developing these interdisciplinary relationships in the future.Sociological Imagination, Water Framework Directive, Sustainability Science, Consumer-Citizens

    Magnetically suspended flywheel system study

    Get PDF
    A program to study the application of a graphite/epoxy, magnetically suspended, pierced disk flywheel for the combined function of spacecraft attitude control and energy storage (ACES) is described. Past achievements of the program include design and analysis computer codes for the flywheel rotor, a magnetically suspended flywheel model, and graphite/epoxy rotor rings that were successfully prestressed via interference assembly. All hardware successfully demonstrated operation of the necessary subsystems which form a complete ACES design. Areas of future work include additional rotor design research, system definition and control strategies, prototype development, and design/construction of a UM/GSFC spin test facility. The results of applying design and analysis computer codes to a magnetically suspended interference assembled rotor show specific energy densities of 42 Wh/lb (92.4 Wh/kg) are obtained for a 1.6 kWh system

    Particle acceleration at ultrarelativistic shocks: an eigenfunction method

    Get PDF
    We extend the eigenfunction method of computing the power-law spectrum of particles accelerated at a relativistic shock fronts to apply to shocks of arbitrarily high Lorentz factor. In agreement with the findings of Monte-Carlo simulations, we find the index of the power-law distribution of accelerated particles which undergo isotropic diffusion in angle at an ultrarelativistic, unmagnetized shock is s=4.23 (where s=-d(ln f)/dp with f the Lorentz invariant phase-space density and p the momentum). This corresponds to a synchrotron index for uncooled electrons of a=0.62 (taking cooling into account a=1.12), where a=-d(ln F)/dn, F is the radiation flux and n the frequency. We also present an approximate analytic expression for the angular distribution of accelerated particles, which displays the effect of particle trapping by the shock: compared with the non-relativistic case the angular distribution is weighted more towards the plane of the shock and away from its normal. We investigate the sensitivity of our results to the transport properties of the particles and the presence of a magnetic field. Shocks in which the ratio of Poynting to kinetic energy flux upstream is not small are less compressive and lead to larger values of ss.Comment: Minor additions on publicatio

    Strike point splitting induced by the application of magnetic perturbations on MAST

    Full text link
    Divertor strike point splitting induced by resonant magnetic perturbations (RMPs) has been observed on MAST for a variety of RMP configurations in a plasma scenario with Ip=750kA where those configurations all have similar resonant components. Complementary measurements have been obtained with divertor Langmuir probes and an infrared camera. Clear splitting consistently appears in this scenario only in the even configuration of the perturbation coils, similarly to the density pump-out. These results present a challenge for models of plasma response to RMPs.Comment: 9 pages, 4 figures, submitted to the proceedings of the 20th Conference on Plasma Surface Interactions, to be published in the Journal of Nuclear Material
    • …
    corecore