301 research outputs found
Percutaneous CT-guided microwave ablation combined with pedicle screw fixation followed by vertebroplasty (MASFVA): initial experience of a minimally invasive treatment of vertebral metastases with extension to the vertebral pedicle
Background: The aim of this study was to retrospectively evaluate the safety and efficacy of a combined CT-guided percutaneous microwave ablation (MWA) and pedicle screw fixation followed by vertebroplasty (MASFVA) for the treatment and stabilization of painful vertebral metastases with vertebral pedicle involvement. (2) Methods: from January 2013 to January 2017 11 patients with 16 vertebral metastatic lesions (7 men and 5 women; mean age, 65 +/- 11 years) with vertebral metastases underwent CT-guided microwave ablation and screw fixation followed by vertebroplasty (MASFVA). Technical success, complication rate, pain evaluation using a visual analogue scale (VAS), Oswestry Disability Index (ODI) and local tumor control were examined. (3) Results: Technical success rate was 100%. No procedure-related major complications occurred. VAS score decreased from 6.8 +/- 0.7 to 0.6 +/- 0.6. ODI score decreased from 3.1 +/- 0.7 to 1.2 +/- 0.4. All patients could walk independently without neurological complication after one week from the procedure. No new bone fractures or local disease recurrence occurred during a median follow-up of 12 months. (4) Conclusions: Our results suggest that MWA and percutaneous pedicle screw fixation followed by vertebroplasty for the treatment of painful vertebral metastases is a safe and effective procedure for painful vertebral metastases with vertebral pedicle involvement, allowing pain relief and local tumor control
The branchial Hox code and its implications for gene regulation, patterning of the nervous system and head evolution
link_to_subscribed_fulltextpublished_or_final_versio
Multipoint temperature monitoring of microwave thermal ablation in bones through fiber bragg grating sensor arrays
Bones are a frequent site of metastases that cause intolerable cancer-related pain in 90% of patients, making their quality of life poor. In this scenario, being able to treat bone oncology patients by means of minimally invasive techniques can be crucial to avoid surgery-related risks and decrease hospitalization times. The use of microwave ablation (MWA) is gaining broad clinical acceptance to treat bone tumors. It is worth investigating temperature variations in bone tissue undergoing MWA because the clinical outcomes can be inferred from this parameter. Several feasibility studies have been performed, but an experimental analysis of the temperature trends reached into the bone during the MWA has not yet been assessed. In this work, a multi-point temperature study along the bone structure during such treatment is presented. The study has been carried out on ex vivo bovine femur and tibia, subjected to MWA. An overall of 40 measurement points covering a large sensing area was obtained for each configuration. Temperature monitoring was performed by using 40 fiber Bragg grating (FBGs) sensors (four arrays each housing 10 FBGs), inserted into the bones at specific distances to the microwave antenna. As result, the ability of this experimental multi-point monitoring approach in tracking temperature variations within bone tissue during MWA treatments was shown. This study lays the foundations for the design of a novel approach to study the effects of MWA on bone tumors. As consequence, the MWA treatment settings could be optimized in order to maximize the treatment effects of such a promising clinical application, but also customized for the specific tumor and patient
Percutaneous Vertebral Reconstruction (PVR) Technique of Pathological Compression Fractures: An Innovative Combined Treatment of Microwave Ablation, Bilateral Expandable Titanium SpineJack Implants Followed by Vertebroplasty
Background: to retrospectively evaluate safety and efficacy of combined microwave ablation (MWA) and bilateral expandable titanium SpineJack (SJ) implants followed by vertebroplasty (VP) for the treatment of painful thoracolumbar pathological vertebral compression fracture. (2) Methods: from July 2017 to October 2022, twenty-eight patients (13 women and 15 men; mean age 68 ± 11 years) with a history of primary neoplasm and thirty-six painful vertebral metastases with vertebral compression fracture underwent combined MWA and bilateral expandable titanium SpineJack implants with vertebroplasty. We analyzed safety through complications rate, and efficacy through vertebral height restoration and pain decrease, evaluated using a visual analogue scale (VAS), and Functional Mobility Scale (FMS), and local tumor control. Contrast-enhanced CT scans were performed at 1, 3, and 6 months and a contrast-enhanced spine MRI at 6 months after the procedure. (3) Results: Technical success rate was 100%. No procedure-related major complications or death occurred. Vertebral height restoration was observed in 22 levels (58%), with a mean anterior height restoration of 2.6 mm ± 0.6 and a mean middle height restoration of 4.4 mm ± 0.6 (p < 0.001). Mean VAS score of pain evaluation on the day before treatment was 6.3 ± 1.5 (range 4–9). At the 6-month evaluation, the median VAS score for pain was 0.4 ± 0.6 (range 0–2) with a mean reduction of 93.65% (6.8 ± 0.7 vs. 0.4 ± 0.6; p < 0.000) compared with baseline evaluation. Contrast-enhanced CT scans were performed at 1, 3, and 6 months and a contrast-enhanced spine MRI was performed at 6 months after the procedure, showing no local recurrence, implant displacement, or new fractures in the treated site. (4) Conclusions: combined microwave ablation and bilateral expandable titanium SpineJack implants with vertebroplasty is a safe and effective procedure for the treatment of pathological compressive vertebral fractures. The vertebral stabilization achieved early and persistent pain relief, increasing patient mobility, improving recovery of walking capacity, and providing local tumor control
Green Tattoo Pre-Operative Renal Embolization for Robotic-Assisted and Laparoscopic Partial Nephrectomy: A Practical Proof of a New Technique
Background: Our aim is to describe a new mixed indocyanine-non-adhesive liquid embolic agent (Onyx-18) pre-operative renal embolization technique for assisted-robotic and laparoscopic partial nephrectomy with near-infra-red fluorescence imaging. (2) Methods: Thirteen patients with biopsy-proven renal tumors underwent pre-operative mixed indocyanine–ethylene vinyl alcohol (EVOH) embolization (Green-embo) between June 2021 and August 2022. All pre-operative embolizations were performed with a super selective stop-flow technique using a balloon microcatheter to deliver an indocyanine-EVOH mixture into tertiary order arterial branch feeders and the intra-lesional vascular supply. Efficacy (evaluated as complete embolization, correct tumor mapping on infra-red fluorescence imaging and clamp-off surgery) and safety (evaluated as complication rate and functional outcomes) were primary goals. Clinical and pathological data were also collected. (3) Results: Two male and eleven female patients (mean age 72 years) received pre-operative Green-embo. The median tumor size was 29 mm (range 15–50 mm). Histopathology identified renal cell carcinoma (RCC) in 9 of the 13 (69%) patients, oncocytoma in 3 of the 13 (23%) patients and sarcomatoid RCC in 1 of the 13 (8%) patients. Lesions were equally distributed between polar, meso-renal, endo- and exophytic locations. Complete embolization was achieved in all the procedures. A correct green mapping was identified during all infra-red fluorescence imaging. All patients were discharged on the second day after the surgery. The median blood loss was 145 cc (10–300 cc). No significant differences were observed in serum creatinine levels before and after the embolization procedures. (4) Conclusions: The Green-tattoo technique based on a mixed indocyanine-non-adhesive liquid embolic agent (Onyx-18) is a safe and effective pre-operative embolization technique. The main advantages are the excellent lesion mapping for fluorescence imaging, reduction in surgical time, and definitive, complete and immediate tumor devascularization based on the deep Onyx-18 penetration, leading to a very low intra-operative blood loss
A prospective risk assessment of informal carers’ medication administration errors within the domiciliary setting
Increasingly, medication is being administered at home by family and friends of the care-recipient. This study aims to identify and analyse risks associated with potential drug administration errors made by informal carers at home. We mapped medication administration at home with a multidisciplinary team that included carers, healthcare professionals and patients. Evidence-based risk-analysis methodologies were applied: Healthcare Failure Modes and Effect Analysis (HFMEA), Systematic Human Error Reduction and Prediction Analysis (SHERPA) and Systems-Theoretic Accident Model and Processes (STAMP). The process of administration comprises seven sub-processes. Thirty four possible failure modes were identified and six of these were rated as high risk. These highlighted that medications may be given with a wrong dose, stored incorrectly, not discontinued as instructed, not recorded, or not ordered on time, and often caused by communication and support problems. Combined risk analyses contributed unique information helpful to better understand the medication administration risks and causes within homecare
A prospective risk assessment of informal carers’ medication administration errors within the domiciliary setting
Increasingly, medication is being administered at home by family and friends of the care-recipient. This study aims to identify and analyse risks associated with potential drug administration errors made by informal carers at home. We mapped medication administration at home with a multidisciplinary team that included carers, healthcare professionals and patients. Evidence-based risk-analysis methodologies were applied: Healthcare Failure Modes and Effect Analysis (HFMEA), Systematic Human Error Reduction and Prediction Analysis (SHERPA) and Systems-Theoretic Accident Model and Processes (STAMP). The process of administration comprises seven sub-processes. Thirty four possible failure modes were identified and six of these were rated as high risk. These highlighted that medications may be given with a wrong dose, stored incorrectly, not discontinued as instructed, not recorded, or not ordered on time, and often caused by communication and support problems. Combined risk analyses contributed unique information helpful to better understand the medication administration risks and causes within homecare
- …