45 research outputs found

    Bilateral vestibulopathy and age:experimental considerations for testing dynamic visual acuity on a treadmill

    Get PDF
    Introduction: Bilateral vestibulopathy (BVP) can affect visual acuity in dynamic conditions, like walking. This can be assessed by testing Dynamic Visual Acuity (DVA) on a treadmill at different walking speeds. Apart from BVP, age itself might influence DVA and the ability to complete the test. The objective of this study was to investigate whether DVA tested while walking, and the drop-out rate (the inability to complete all walking speeds of the test) are significantly influenced by age in BVP-patients and healthy subjects. Methods: Forty-four BVP-patients (20 male, mean age 59 years) and 63 healthy subjects (27 male, mean age 46 years) performed the DVA test on a treadmill at 0 (static condition), 2, 4 and 6 km/h (dynamic conditions). The dynamic visual acuity loss was calculated as the difference between visual acuity in the static condition and visual acuity in each walking condition. The dependency of the drop-out rate and dynamic visual acuity loss on BVP and age was investigated at all walking speeds, as well as the dependency of dynamic visual acuity loss on speed. Results: Age and BVP significantly increased the drop-out rate (p ≤ 0.038). A significantly higher dynamic visual acuity loss was found at all speeds in BVP-patients compared to healthy subjects (p < 0.001). Age showed no effect on dynamic visual acuity loss in both groups. In BVP-patients, increasing walking speeds resulted in higher dynamic visual acuity loss (p ≤ 0.036). Conclusion DVA tested while walking on a treadmill, is one of the few “close to reality” functional outcome measures of vestibular function in the vertical plane. It is able to demonstrate significant loss of DVA in bilateral vestibulopathy patients. However, since bilateral vestibulopathy and age significantly increase the drop-out rate at faster walking speeds, it is recommended to use age-matched controls. Furthermore, it could be considered to use an individual “preferred” walking speed and to limit maximum walking speed in older subjects when testing DVA on a treadmill

    Multi-frequency VEMPs improve detection of present otolith responses in bilateral vestibulopathy

    Get PDF
    ObjectiveTo investigate whether multi-frequency Vestibular Evoked Myogenic Potential (VEMP) testing at 500, 750, 1,000, and 2,000 Hz, would improve the detection of present dynamic otolith responses in patients with bilateral vestibulopathy (BV).MethodsProspective study in a tertiary referral center. BV patients underwent multi-frequency VEMP testing. Cervical VEMPs and ocular VEMPs were recorded with the Neuro-Audio system (v2010, Neurosoft, Ivanovo, Russia). The stimuli included air-conducted tone bursts of 500, 750, 1,000, and 2,000 Hz, at a stimulation rate of 13 Hz. Outcome measures included the percentage of present and absent VEMP responses, and VEMP thresholds. Outcomes were compared between frequencies and type of VEMPs (cVEMPs, oVEMPs). VEMP outcomes obtained with the 500 Hz stimulus, were also compared to normative values obtained in healthy subjects.ResultsForty-nine BV patients completed VEMP testing: 47 patients completed cVEMP testing and 48 patients completed oVEMP testing. Six to 15 % more present VEMP responses were obtained with multifrequency testing, compared to only testing at 500 Hz. The 2,000 Hz stimulus elicited significantly fewer present cVEMP responses (right and left ears) and oVEMP responses (right ears) compared to the other frequencies (p ≤ 0.044). Using multi-frequency testing, 78% of BV patients demonstrated at least one present VEMP response in at least one ear. In 46% a present VEMP response was found bilaterally. BV patients demonstrated a significantly higher percentage of absent VEMP responses and significantly higher VEMP thresholds than healthy subjects, when corrected for age (p ≤ 0.002). Based on these results, a pragmatic VEMP testing paradigm is proposed, taking into account multi-frequency VEMP testing.ConclusionMulti-frequency VEMP testing improves the detection rate of present otolith responses in BV patients. Therefore, multi-frequency VEMPs should be considered when evaluation of (residual) otolith function is indicated

    Einfluss neuer Technologien in Marvel-Hörsystemen auf das Sprachverstehen von CI-Trägern

    No full text

    Vestibular implant on the threshold of clinical application?

    No full text

    Vestibular assistance systems: promises and challenges

    Get PDF
    The handicap resulting from a bilateral vestibular deficit is often underestimated. In most cases the deficit settles gradually. Patients do not understand what is happening to them and have many difficulties to describe their symptoms. They have to consult several doctors with different medical specialties before diagnosis. Once the diagnosis is made there is no biological way to "repair'' the deficient vestibular apparatus and vestibular exercises are mildly effective. Attempts have been made to help patients using substitution devices replacing the defective vestibular information by tactile or acoustic cues. Currently, efforts are being made towards the development of a vestibular implant, conceptually similar to the cochlear implant for the rehabilitation of deaf patients. In recent years, several experiments on animal models have demonstrated the feasibility of this project. This paper reports the steps accomplished in human experiments and the main results obtained in our laboratory

    A real-time research platform to study vestibular implants with gyroscopic inputs in vestibular deficient subjects

    No full text
    Researchers have succeeded in partly restoring damaged vestibular functionality in several animal models. Recently, acute interventions have also been demonstrated in human patients. Our previous work on a vestibular implant for humans used predefined stimulation patterns; here we present a research tool that facilitates motion-modulated stimulation. This requires a system that can process gyroscope measurements and send stimulation parameters to a hybrid vestibular-cochlear implant in real-time. To match natural vestibular latencies, the time from sensor input to stimulation output should not exceed 6.5 ms. We describe a system based on National Instrument's CompactRIO platform that can meet this requirement and also offers floating point precision for advanced transfer functions. It is designed for acute clinical interventions, and is sufficiently powerful and flexible to serve as a development platform for evaluating prosthetic control strategies. Amplitude and pulse frequency modulation to predetermined functions or sensor inputs have been validated. The system has been connected to human patients, who each have received a modified MED-EL cochlear implant for vestibular stimulation, and patient tests are ongoing

    The resilience of the inner ear: vestibular and audiometric impact of transmastoid semicircular canal plugging

    No full text
    Background: Certain cases of superior semicircular canal dehiscence or benign paroxysmal positional vertigo can be treated by plugging of the affected semicircular canal. However, the extent of the impact on vestibular function and hearing during postoperative follow-up is not known. Objective: To evaluate the evolution of vestibular function and hearing after plugging of a semicircular canal. Methods: Six patients underwent testing before and 1 week, 2 months, and 6 months after plugging of the superior or posterior semicircular canal. Testing included caloric irrigation test, video Head Impulse Test (vHIT), cervical and ocular Vestibular Evoked Myogenic Potentials (VEMPs) and audiometry. Results: Initially, ipsilateral caloric response decreased in all patients and vHIT vestibulo-ocular reflex (VOR) gain of each ipsilateral semicircular canal decreased in 4/6 patients. In 4/6 patients, postoperative caloric response recovered to > 60% of the preoperative value. In 5/6 patients, vHIT VOR gain was restored to > 85% of the preoperative value for both ipsilateral non-plugged semicircular canals. In the plugged semicircular canal, this gain decreased in 4/5 patients and recovered to > 50% of the preoperative value. Four patients preserved cervical and ocular VEMP responses. Bone conduction hearing deteriorated in 3/6 patients, but recovered within 6 months postoperatively, although one patient had a persistent loss of 15 dB at 8 kHz. Conclusion Plugging of a semicircular canal can affect both vestibular function and hearing. After initial deterioration, most patients show recovery during follow-up. However, a vestibular function loss or high-frequency hearing loss can persist. This stresses the importance of adequate counseling of patients considering plugging of a semicircular canal

    Response variability to high rates of electric stimulation in retinal ganglion cells

    No full text
    To improve the quality of prosthetic vision, it is important to understand how retinal neurons respond to electric stimulation. Previous studies present conflicting reports as to the maximum rate at which retinal ganglion cells can “follow” pulse trains, i.e., generate one spike for each pulse of the train. In the present study, we measured the response of 5 different types of rabbit retinal ganglion cells to pulse trains of 100–700 Hz. Surprisingly, we found significant heterogeneity in the ability of different types to follow pulse trains. For example, brisk transient (BT) ganglion cells could reliably follow pulse rates up to 600 pulses per second (PPS). In contrast, other types could not even follow rates of 200 PPS. There was additional heterogeneity in the response patterns across those types that could not follow high-rate trains. For example, some types generated action potentials in response to approximately every other pulse, whereas other types generated one spike per pulse for a few consecutive pulses and then did not generate any spikes in response to the next few pulses. Interestingly, in the types that could not follow high-rate trains, we found a second type of response: many pulses of the train elicited a biphasic waveform with an amplitude much smaller than that of standard action potentials. This small waveform was often observed following every pulse for which a standard spike was not elicited. A possible origin of the small waveform and its implication for effective retinal stimulation are discussed

    Influence of systematic variations of the stimulation profile on responses evoked with a vestibular implant prototype in humans

    Get PDF
    Objective: To explore the impact of different electrical stimulation profiles in human recipients of the Geneva-Maastricht vestibular implant prototypes. Approach: Four implanted patients were recruited for this study. We investigated the relative efficacy of systematic variations of the electrical stimulus profile (phase duration, pulse rate, baseline level, modulation depth) in evoking vestibulo-ocular (eVOR) and perceptual responses. Main results: Shorter phase durations and, to a lesser extent, slower pulse rates allowed maximizing the electrical dynamic range available for eliciting a wider range of intensities of vestibular percepts. When each either phase duration or pulse rate was held constant, current modulation depth was the factor that had the most significant impact on peak velocity of the eVOR. Significance: Our results identified important parametric variations that influence the measured responses. Furthermore, we observed that not all vestibular pathways seem equally sensitive to the electrical stimulus when the electrodes are placed in the semicircular canals and monopolar stimulation is used. This opens the door to evaluating new stimulation strategies for a vestibular implant, and suggests the possibility of selectively activating one vestibular pathway or the other in order to optimize rehabilitation outcomes
    corecore