3,471 research outputs found
Fourier series for eclipses on exoplanet binaries
A double planet system or planet binary undergoes eclipses that modify the
reflective light curve. In the time domain, the eclipse events are fast and
weak. This would make their signal difficult to find and recognize in the phase
light curve, even for small inclinations when eclipses happen frequently.
However, due to the quasiperiodic nature of the phenomenon, the Fourier
transform of the direct reflection signal consists of a double sum of sharp
peaks. These peaks can be resolved for large close binaries and sufficiently
long observation times with a star coronagraph. Eclipses modulate the phase
curve, having an orbital period , with a contribution from the
relative motion in the binary plane of a period . This leads to a
spectral structure with basis frequencies and . We aim to
characterize these spectra. We studied the regime of short eclipses that occur
when the planet radii are small compared to the planet separation. We derived
formulas for the peak amplitudes applicable to homogeneous (Lambertian) planet
binaries in circular orbit with small inclination. The effects of an eclipse
and of double reflection appear as first- and second-order contributions (in
planet radius over separation) in the reflection signal respectively. Small
peaks appear as observable side bands in the spectrum. Identical structures
around are characteristic of short-duration eclipses. Deceasing side
bands could indicate double reflection between companions. Fourier analysis of
the light curve of non-transiting planets can be used to find planets and their
moons. Difficulties in interpreting the structures arise for small planet
separation and when there are several moons in mean-motion resonance.Comment: 12 pages, 10 figure
Aspects of Cooling at the TRIP Facility
The TriP facility at KVI is dedicated to provide short lived radioactive
isotopes at low kinetic energies to users. It comprised different cooling
schemes for a variety of energy ranges, from GeV down to the neV scale. The
isotopes are produced using beam of the AGOR cyclotron at KVI. They are
separated from the primary beam by a magnetic separator. A crucial part of such
a facility is the ability to stop and extract isotopes into a low energy
beamline which guides them to the experiment. In particular we are
investigating stopping in matter and buffer gases. After the extraction the
isotopes can be stored in neutral atoms or ion traps for experiments. Our
research includes precision studies of nuclear -decay through
- momentum correlations as well as searches for permanent electric
dipole moments in heavy atomic systems like radium. Such experiments offer a
large potential for discovering new physics.Comment: COOL05 Workshop, Galena, Il, USA, 18-23. Sept. 2005, 5 pages, 3
figure
Effect of helium pre- or postconditioning on signal transduction kinases in patients undergoing coronary artery bypass graft surgery
Background: The noble gas helium induces pre- and postconditioning in animals and humans. Volatile anesthetics induce cardioprotection in humans undergoing coronary artery bypass graft (CABG) surgery. We hypothesized that helium induces pre-and postconditioning in CABG-patients, affecting signaling molecules protein kinase C-epsilon (PKC-epsilon), p38 mitogen activated protein kinase (p38 MAPK), extracellular signal-regulated kinase 1/2 (ERK-1/2) and heat shock protein 27 (HSP-27) within cardiac tissue, and reducing postoperative troponin levels.
Methods: After ethical approval and informed consent, 125 elective patients undergoing CABG surgery were randomised into this prospective, placebo controlled, investigator blinded, parallel arm single-centre study. Helium preconditioning (3 x 5 min of 70 % helium and 30 % oxygen) was applied before aortic cross clamping; postconditioning (15 min of helium) was applied before release of the aortic cross clamp. Signaling molecules were measured in right atrial appendix specimens. Troponin-T was measured at 4, 12, 24 and 48 h postoperatively.
Results: Baseline characteristics of all groups were similar. Helium preconditioning did not significantly alter the primary outcome (molecular levels of kinases PKC-e and HSP-27, ratio of activated p38 MAPK or ERK 1/2). Postoperative troponin T was 11 arbitrary units [5, 31; area-under-the-curve (interquartile range)] for controls, and no statistically significant changes were observed after helium preconditioning [He-pre: 11 (6, 18)], helium postconditioning [He-post: 11 (8, 15)], helium pre-and postconditioning [He-PP: 14 (6, 20)] and after sevoflurane preconditioning [APC: 12 (8, 24), p = 0.13]. No adverse effects related to study treatment were observed in this study.
Conclusions: No effect was observed of helium preconditioning, postconditioning or the combination thereof on activation of p38 MAPK, ERK 1/2 or levels of HSP27 and PKC-e in the human heart. Helium pre-and postconditioning did not affect postoperative troponin release in patients undergoing CABG surgery
Layer dynamics of a freely standing smectic-A film
We study the hydrodynamics of a freely-standing smectic-A film in the
isothermal, incompressible limit theoretically by analyzing the linearized
hydrodynamic equations of motion with proper boundary conditions. The dynamic
properties for the system can be obtained from the response functions for the
free surfaces. Permeation is included and its importance near the free surfaces
is discussed. The hydrodynamic mode structure for the dynamics of the system is
compared with that of bulk systems. We show that to describe the dynamic
correlation functions for the system, in general, it is necessary to consider
the smectic layer displacement and the velocity normal to the layers,
, together. Finally, our analysis also provides a basis for the
theoretical study of the off-equilibrium dynamics of freely-standing smectic-A
films.Comment: 22 pages, 4 figure
- …