343 research outputs found

    Integration of a Smartphone HF-Dedicated App in the Remote Monitoring of Heart Failure Patients with Cardiac Implantable Electronic Devices: Patient Access, Acceptance, and Adherence to Use

    Get PDF
    (200 w) Introduction. Remote monitoring (RM) of cardiac implantable electronic device (CIED) diagnostics helps to identify patients potentially at risk of worsening heart failure (HF). Additionally, knowledge of patient HF-related symptoms is crucial for decision making. Patient smartphone applications may represent an ideal option to remotely collect this information. Purpose. To assess real-world HF patient access, acceptance, and adherence to use of an HF-dedicated smartphone application (HF app). Methods. In this study, 10 Italian hospitals administered a survey on smartphone/app use to HF patients with CIED. The subgroup who accepted it downloaded the HF app. Mean 1-year adherence of the HF app use was evaluated. Results. A total of 495 patients (67 ± 13 years, 79% males, 26% NYHA III–IV) completed the survey, of which 84% had access to smartphones and 85% were willing to use the HF app. In total, 311/495 (63%) downloaded the HF app. Patients who downloaded the HF app were younger and had higher school qualification. Patients who were ≄60 years old had higher mean 1-year adherence (54.1%) than their younger counterparts (42.7%; p < 0.001). Hospitals with RM-dedicated staff had higher mean 1-year patient adherence (64.0% vs. 33.5%; p < 0.001). Adherence to HF app decreased from 63.3% (weeks_1–13) to 42.2% (weeks_40–52, p < 0.001). Conclusions. High access and acceptance of smartphones/apps by HF patients with CIED allow HF app use for RM of patient signs/symptoms. Younger patients with higher school qualifications are more likely to accept HF app; however, older patients have higher long-term adherence

    Cardiac resynchronization therapy-defibrillator improves long-term survival compared with cardiac resynchronization therapy-pacemaker in patients with a class IA indication for cardiac resynchronization therapy: Data from the Contak Italian Registry

    Get PDF
    Aims In candidates for cardiac resynchronization therapy (CRT), the choice between pacemaker (CRT-P) and defibrillator (CRT-D) implantation is still debated. We compared the long-term prognosis of patients who received CRT-D or CRT-P according to class IA recommendations of the European Society of Cardiology (ESC) and who were enrolled in a multicentre prospective registry. Methods and results A total of 620 heart failure patients underwent successful implantation of a CRT device and were enrolled in the Contak Italian Registry. This analysis included 266 patients who received a CRT-D and 108 who received a CRT-P according to class IA ESC indications. Their survival status was verified after a median follow-up of 55 months. During follow-up, 73 CRT-D and 44 CRT-P patients died (rate 6.6 vs. 10.4%/year; log-rank test, P = 0.020). Patients receiving CRT-P were predominantly older, female, had no history of life-threatening ventricular arrhythmias, and more frequently presented non-ischaemic aetiology of heart failure, longer QRS durations, and worse renal function. However, the only independent predictor of death from any cause was the use of CRT-P (hazard ratio, 1.97; 95% confidence interval, 1.21–3.16; P = 0.007). Conclusion The implantation of CRT-D, rather than CRT-P, may be preferable in patients presenting with current class IA ESC indications for CRT. Indeed, CRT-D resulted in greater long-term survival and was independently associated with a better prognosis

    Prognostic Value of T-Wave Alternans in Patients With Heart Failure Due to Nonischemic Cardiomyopathy Results of the ALPHA Study

    Get PDF
    ObjectivesThe aim of this study was to assess the prognostic value of T-wave alternans (TWA) in New York Heart Association (NYHA) functional class II/III patients with nonischemic cardiomyopathy and left ventricular ejection fraction (LVEF) ≀40%.BackgroundThere is a strong need to identify reliable risk stratifiers among heart failure candidates for implantable cardioverter-defibrillator (ICD) prophylaxis. T-wave alternans may identify low-risk subjects among post-myocardial infarction patients with depressed LVEF, but its predictive role in nonischemic cardiomyopathy is unclear.MethodsFour hundred forty-six patients were enrolled and followed up for 18 to 24 months. The primary end point was the combination of cardiac death + life-threatening arrhythmias; secondary end points were total mortality and the combination of arrhythmic death + life-threatening arrhythmias.ResultsPatients with abnormal TWA (65%) compared with normal TWA (35%) tests were older (60 ± 13 years vs. 57 ± 12 years), were more frequently in NYHA functional class III (22% vs. 19%), and had a modestly lower LVEF (29 ± 7% vs. 31 ± 7%). Primary end point rates in patients with abnormal and normal TWA tests were 6.5% (95% confidence interval [CI] 4.5% to 9.4%) and 1.6% (95% CI 0.6% to 4.4%), respectively. Unadjusted and adjusted hazard ratios were 4.0 (95% CI 1.4% to 11.4%; p = 0.002) and 3.2 (95% CI 1.1% to 9.2%; p = 0.013), respectively. Hazard ratios for total mortality and for arrhythmic death + life-threatening arrhythmias were 4.6 (p = 0.002) and 5.5 (p = 0.004), respectively; 18-month negative predictive values for the 3 end points ranged between 97.3% and 98.6%.ConclusionsAmong NYHA functional class II/III nonischemic cardiomyopathy patients, an abnormal TWA test is associated with a 4-fold higher risk of cardiac death and life-threatening arrhythmias. Patients with normal TWA tests have a very good prognosis and are likely to benefit little from ICD therapy

    Tradução e adaptação transcultural para o Brasil do Pediatric Confusion Assessment Method for the Intensive Care Unit para detecção de delirium em unidades de terapia intensiva pediåtrica

    Get PDF
    Objective: To undertake the translation and cross-cultural adaption into Brazilian Portuguese of the Pediatric Confusion Assessment Method for the Intensive Care Unit for the detection of delirium in pediatric intensive care units, including the algorithm and instructions. Methods: A universalist approach for the translation and cross-cultural adaptation of health measurement instruments was used. A group of pediatric critical care specialists assessed conceptual and item equivalences. Semantic equivalence was evaluated by means of a translation from English to Portuguese by two independent translators; reconciliation into a single version; back-translation by a native English speaker; and consensus among six experts with respect to language and content understanding by means of Likert scale responses and the Content Validity Index. Finally, operational equivalence was assessed by applying a pre-test to 30 patients. Results: The back-translation was approved by the original authors. The medians of the expert consensus responses varied between good and excellent, except for the feature “acute onset” of the instructions. Items with a low Content Validity Index for the features “acute onset” and “disorganized thinking” were adapted. In the pre-test, the expression “signal with your head” was modified into “nod your head” for better understanding. No further adjustments were necessary, resulting in the final version for Brazilian Portuguese. Conclusion: The Brazilian version of the Pediatric Confusion Assessment Method for the Intensive Care Unit was generated in agreement with the international recommendations and can be used in Brazil for the diagnosis of delirium in critically ill children 5 years of age or above and with no developmental cognitive disabilities

    Manual / Issue 4 / Blue

    Get PDF
    Manual, a journal about art and its making. Blue.The fourth issue. Indigo blue, ultramarine blue, cobalt blue, cerulean blue, zaffre blue, indanthrone blue, phthalo blue, cyan blue, Han blue, French blue, Berlin blue, Prussian blue, Venetian blue, Dresden blue, Tiffany blue, Lanvin blue, Majorelle blue, International Klein Blue, Facebook blue. The names given to different shades of blue speak of plants, minerals, and modern chemistry; exoticism, global trade, and national pride; capitalist branding and pure invention. The fourth issue of Manual is a meditation on blue. From precious substance to controllable algorithm to the wide blue yonder, join us as we leap into the blue. Softcover, 64 pages. Published 2015 by the RISD Museum. Proceeds from RISD Museum publications support the work of the museum. Manual 4 (Blue) contributors include Lawrence Berman, A. Will Brown, Linda Catano, Spencer Fitch, Jessica Helfand, Kate Irvin, Oda van Maanen, Dominic Molon, Maggie Nelson, Ingrid A. Neuman, Margot Nishimura, Karen B. Schloss, Anna Strickland, Louis van Tilborgh, and Elizabeth A. Williams.https://digitalcommons.risd.edu/risdmuseum_journals/1003/thumbnail.jp

    Manual / Issue 10 / Polychrome

    Get PDF
    Manual, a journal about art and its making. Polychrome. In art, especially, polychrome invites us to the dialogue that colors are always having amongst themselves. A history of polychrome could be a series of poems exchanged among colors. The exchange might exhibit something like perpetual newness, again and again revealing differently bent hues and movingly novel blends. It would be a short-line poetry, excruciatingly sensitive to tone. Its speakers would have no names, so it would confuse the psychology of human orientation. In this connection, a warning against rendering polychrome as a pure positive seems in order: the parties to this dialogue talk at cross-purposes, always on the brink of divorcing. Polychrome can offend and destroy. It conscripts discrete colors in order to sacrifice them. Does polychrome offend by mocking our own failure to connect? In any case, polychrome has an advanced idiom for dealing with conflict. It’s at home with uncertainty. —Darby English, from the introduction to Issue 10: Polychrome. Softcover, 80 pages. Published 2018 by the RISD Museum. Manual 10 (Polychrome) contributors include David Batchelor, Gina Borromeo, Nicole Buchanan, Catherine Cooper, Darby English, Mara L. Hermano, Elon Cook Lee, Josephine Lee, Evelyn Lincoln, Dominic Molon, Maureen C. O\u27Brien, RISD Museum 2017 Summer Teen Intensive Students, and Elizabeth A. Williams.https://digitalcommons.risd.edu/risdmuseum_journals/1036/thumbnail.jp

    Manual / Issue 7 / Alchemy

    Get PDF
    Manual, a journal about art and its making. Alchemy. The seventh issue. Manual 7 (Alchemy) prompts the unexpected and emergent to manifest. To engage as an alchemist/artist is to be the perpetual student of the present moment, to synthesize culture, so-called science, and the implications of existential borders into a discipline that is repeatable, a practice. Art and alchemy are not singular, unified pursuits. Their practitioners are trans-disciplinary, disjointed, and solitary in their practice, and their labor and the ordering of their lives become porous, overlaid in the pursuit of other-than or beyond-dominant modes of understanding. Alchemy and art are not about finding resolution, but building the capacity for curiosity, formulating questions that invest fields of knowledge with possibility, prompting the unexpected and emergent to manifest. —Bryan McGovern Wilson, from the introduction to Issue 7: Alchemy Softcover, 76 pages. Published 2016 by the RISD Museum. Manual 7 (Alchemy) contributors include Markus Berger, Rachel Berwick, Stephen S. Bush, CA Conrad, Florence Friedman, Doreen Garner, Michael Grugl, Kate Irvin, Mimi Leveque, Dominic Molon, Douglas R. Nickel, Emily J. Peters, Elizabeth A. Williams, Bryan McGovern Wilson, and Diming Stella Zhong.https://digitalcommons.risd.edu/risdmuseum_journals/1033/thumbnail.jp
    • 

    corecore