52 research outputs found

    Experiences with surgical treatment of ventricle septal defect as a post infarction complication

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Complications of acute myocardial infarction (AMI) with mechanical defects are associated with poor prognosis. Surgical intervention is indicated for a majority of these patients. The goal of surgical intervention is to improve the systolic cardiac function and to achieve a hemodynamic stability. In this present study we reviewed the outcome of patients with post infarction ventricular septal defect (PVSD) who underwent cardiac surgery.</p> <p>Methods</p> <p>We analysed retrospectively the hospital records of 41 patients, whose ages range from 48 to 81, and underwent a surgical treatment between 1990 and 2005 because of PVSD.</p> <p>Results</p> <p>In 22 patients concomitant coronary artery bypass grafting (CAGB) was performed. In 15 patients a residual shunt was found, this required re-op in seven of them. The time interval from infarct to rupture was 8.7 days and from rupture to surgery was 23.1 days. Hospital mortality in PVSD group was 32%. The mortality of urgent repair within 3 days of intractable cardiogenic shock was 100%. The mortality of patients with an anterior VSD and a posterior VSD was 29.6% vs 42.8%, respectively. All patients who underwent the surgical repair later than day 36 survived.</p> <p>Conclusion</p> <p>Surgical intervention is indicated for a majority of patients with mechanical complications. Cardiogenic shock remains the most important factor that affects the early results. The surgical repair of PVSD should be performed 4–5 weeks after AMI. To improve surgical outcome and hemodynamics the choice of surgical technique and surgical timing as well as preoperative management should be tailored for each patient individually.</p

    Extracorporeal life support in pediatric cardiac dysfunction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Low cardiac output (LCO) after corrective surgery remains a serious complication in pediatric congenital heart diseases (CHD). In the case of refractory LCO, extra corporeal life support (ECLS) extra corporeal membrane oxygenation (ECMO) or ventricle assist devices (VAD) is the final therapeutic option. In the present study we have reviewed the outcomes of pediatric patients after corrective surgery necessitating ECLS and compared outcomes with pediatric patients necessitating ECLS because of dilatated cardiomyopathy (DCM).</p> <p>Methods</p> <p>A retrospective single-centre cohort study was evaluated in pediatric patients, between 1991 and 2008, that required ECLS. A total of 48 patients received ECLS, of which 23 were male and 25 female. The indications for ECLS included CHD in 32 patients and DCM in 16 patients.</p> <p>Results</p> <p>The mean age was 1.2 ± 3.9 years for CHD patients and 10.4 ± 5.8 years for DCM patients. Twenty-six patients received ECMO and 22 patients received VAD. A total of 15 patients out of 48 survived, 8 were discharged after myocardial recovery and 7 were discharged after successful heart transplantation. The overall mortality in patients with extracorporeal life support was 68%.</p> <p>Conclusion</p> <p>Although the use of ECLS shows a significantly high mortality rate it remains the ultimate chance for children. For better results, ECLS should be initiated in the operating room or shortly thereafter. Bridge to heart transplantation should be considered if there is no improvement in cardiac function to avoid irreversible multiorgan failure (MFO).</p

    The Chemical Evolution of the La0.6Sr0.4CoO3−δ Surface Under SOFC Operating Conditions and Its Implications for Electrochemical Oxygen Exchange Activity

    Get PDF
    © The Author(s) 2018Owing to its extraordinary high activity for catalysing the oxygen exchange reaction, strontium doped LaCoO3 (LSC) is one of the most promising materials for solid oxide fuel cell (SOFC) cathodes. However, under SOFC operating conditions this material suffers from performance degradation. This loss of electrochemical activity has been extensively studied in the past and an accumulation of strontium at the LSC surface has been shown to be responsible for most of the degradation effects. The present study sheds further light onto LSC surface changes also occurring under SOFC operating conditions. In-situ near ambient pressure X-ray photoelectron spectroscopy measurements were conducted at temperatures between 400 and 790 °C. Simultaneously, electrochemical impedance measurements were performed to characterise the catalytic activity of the LSC electrode surface for O2 reduction. This combination allowed a correlation of the loss in electro-catalytic activity with the appearance of an additional La-containing Sr-oxide species at the LSC surface. This additional Sr-oxide species preferentially covers electrochemically active Co sites at the surface, and thus very effectively decreases the oxygen exchange performance of LSC. Formation of precipitates, in contrast, was found to play a less important role for the electrochemical degradation of LSC.Fonds zur Förderung der wissenschaftlichen Forschung (FWF)212921411

    Leitbilder medizinischer Professionsvertreter

    No full text

    OSCE mit standardisierten Patienten

    No full text

    Biofilm development on urinary catheters promotes the appearance of viable but nonculturable bacteria

    No full text
    Catheter-associated urinary tract infections have serious consequences, for both patients and health care resources. Much work has been carried out to develop an antimicrobial catheter. Although such developments have shown promise under laboratory conditions, none have demonstrated a clear advantage in clinical trials. Using a range of microbiological and advanced microscopy techniques, a detailed laboratory study comparing biofilm development on silicone, hydrogel latex, and silver alloy-coated hydrogel latex catheters was carried out. Biofilm development by Escherichia coli, Pseudomonas aeruginosa, and Proteus mirabilis on three commercially available catheters was tracked over time. Samples were examined with episcopic differential interference contrast (EDIC) microscopy, culture analysis, and staining techniques to quantify viable but nonculturable (VBNC) bacteria. Both qualitative and quantitative assessments found biofilms to develop rapidly on all three materials. EDIC microscopy revealed the rough surface topography of the materials. Differences between culture counts and quantification of total and dead cells demonstrated the presence of VBNC populations, where bacteria retain viability but are not metabolically active. The use of nonculture-based techniques showed the development of widespread VBNC populations. These VBNC populations were more evident on silver alloy-coated hydrogel latex catheters, indicating a bacteriostatic effect at best. The laboratory tests reported here, which detect VBNC bacteria, allow more rigorous assessment of antimicrobial catheters, explaining why there is often minimal benefit to patients.IMPORTANCE Several antimicrobial urinary catheter materials have been developed, but, although laboratory studies may show a benefit, none have significantly improved clinical outcomes. The use of poorly designed laboratory testing and lack of consideration of the impact of VBNC populations may be responsible. While the presence of VBNC populations is becoming more widely reported, there remains a lack of understanding of the clinical impact or influence of exposure to antimicrobial products. This is the first study to investigate the impact of antimicrobial surface materials and the appearance of VBNC populations. This demonstrates how improved testing is needed before clinical trials are initiated.</p

    The good doctor - Visions of professors and practinioneers

    No full text
    corecore