160 research outputs found
A microfluidic electroosmotic mixer and the effect of potential and frequency on its mixing efficiency
This paper presents the design and numerical simulation of a T-shape microfluidic electroosmotic micromixer. It is equipped with six microelectrodes that are embedded in the side surfaces of the microchannel. The electrode array consists of two sets of three 20 ¿m and 60 ¿m microelectrodes arranged in the form of two opposing triangles. Numerical analysis of electric potential and frequency effects on mixing efficiency of the micromixer is carried out by means of two sets of simulations. First, the electric potential is kept at 2 V while the frequency is varied within 10-50 Hz. The highest achieved mixing efficiency is 96% at 22 Hz. Next, the frequency is kept at 30 Hz whilst the electric potential is varied within 1-5 V. The best achieved mixing efficiency is 97% at 3 V.<br /
Dielectrophoretically tuneable optical waveguides using nanoparticles in microfluidics
We present a tuneable optical waveguide using dielectrophoretically controlled nanoparticles in microfluidics. Silicon dioxide nanoparticles of different sizes in de-ionized water are channelled through a microfluidic system. An array of microelectrodes generates the dielectrophoretic force to funnel nanoparticles, forming narrowbands at the center of the microfluidics at different applied voltages and frequencies. It is observed that these narrowbands either scatter or guide the coupled light under selected conditions. The realization of such a system offers exciting possibilities for the development of a new class of optofluidics, which are tuned by the positioning of nanoparticles on demand
Dielectrophoresis of micro/nano particles using curved microelectrodes
Dielectrophoresis, the induced motion of polarisable particles in non-homogenous electric field, has been proven as a versatile mechanism to transport, immobilise, sort and characterise micro/nano scale particle in microfluidic platforms. The performance of dielectrophoretic (DEP) systems depend on two parameters: the configuration of microelectrodes designed to produce the DEP force and the operating strategies devised to employ this force in such processes. This work summarises the unique features of curved microelectrodes for the DEP manipulation of target particles in microfluidic systems. The curved microelectrodes demonstrate exceptional capabilities including (i) creating strong electric fields over a large portion of their structure, (ii) minimising electro-thermal vortices and undesired disturbances at their tips, (iii) covering the entire width of the microchannel influencing all passing particles, and (iv) providing a large trapping area at their entrance region, as evidenced by extensive numerical and experimental analyses. These microelectrodes have been successfully applied for a variety of engineering and biomedical applications including (i) sorting and trapping model polystyrene particles based on their dimensions, (ii) patterning carbon nanotubes to trap low-conductive particles, (iii) sorting live and dead cells based on their dielectric properties, (iv) real-time analysis of drug-induced cell death, and (v) interfacing tumour cells with environmental scanning electron microscopy to study their morphological properties. The DEP systems based on curved microelectrodes have a great potential to be integrated with the future lab-on-a-chip systems.<br /
Probing the action of a novel anti-leukaemic drug therapy at the single cell level using modern vibrational spectroscopy techniques
Acute myeloid leukaemia (AML) is a life threatening cancer for which there is an urgent clinical need for novel therapeutic approaches. A redeployed drug combination of bezafibrate and medroxyprogesterone acetate (BaP) has shown anti-leukaemic activity in vitro and in vivo. Elucidation of the BaP mechanism of action is required in order to understand how to maximise the clinical benefit. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, Synchrotron radiation FTIR (S-FTIR) and Raman microspectroscopy are powerful complementary techniques which were employed to probe the biochemical composition of two AML cell lines in the presence and absence of BaP. Analysis was performed on single living cells along with dehydrated and fixed cells to provide a large and detailed data set. A consideration of the main spectral differences in conjunction with multivariate statistical analysis reveals a significant change to the cellular lipid composition with drug treatment; furthermore, this response is not caused by cell apoptosis. No change to the DNA of either cell line was observed suggesting this combination therapy primarily targets lipid biosynthesis or effects bioactive lipids that activate specific signalling pathways
Phosphorus–iron interaction in sediments : can an electrode minimize phosphorus release from sediments?
All restoration strategies to mitigate eutrophication depend on the success of phosphorus (P) removal from the water body. Therefore, the inputs from the watershed and from the enriched sediments, that were the sink of most P that has been discharged in the water body, should be controlled. In sediments, iron (hydr)oxides minerals are potent repositories of P and the release of P into the water column may occur upon dissolution of the iron (hydr)oxides mediated by iron reducing bacteria. Several species of these bacteria are also known as electroactive microorganisms and have been recently identified in lake sediments. This capacity of bacteria to transfer electrons to electrodes, producing electricity from the oxidation of organic  matter, might play a role on P release in sediments. In the present work it is discussed the relationship between phosphorus and iron cycling as well as the application of an electrode to work as external electron acceptor in sediments, in order to prevent metal bound P dissolution under anoxic conditions.The authors are grateful to two anonymous reviewers of a previous version of the manuscript for the constructive comments and suggestions. The authors also acknowledge the Grant SFRH/BPD/80528/2011 from the Foundation for Science and Technology, Portugal, awarded to Gilberto Martins
Dynamics of high viscosity contrast confluent microfluidic flows
The laminar nature of microfluidic flows is most elegantly demonstrated via the confluence of two fluids forming two stable parallel flows within a single channel meeting at a highly stable interface. However, maintenance of laminar conditions can become complicated when there is a large viscosity contrast between the neighbouring flows leading to unique instability patterns along their interface. Here, we study the dynamics of high viscosity contrast confluent flows - specifically a core flow made of highly viscous glycerol confined by sheath flows made of water within a microfluidic flow focusing system. Our experiments indicate the formation of tapered core structures along the middle of the channel. Increasing the sheath flow rate shortens the tapered core, and importantly induces local instability patterns along the interface of core-sheath flows. The dynamics of such tapered core structures is governed by the intensity of instability patterns and the length of the core, according to which the core structure can experience stable, disturbed, broken or oscillated regimes. We have studied the dynamics of tapered core structures under these regimes. In particular, we have analysed the amplitude and frequency of core displacements during the broken core and oscillating core regimes, which have not been investigated before
Mixing characterisation for a serpentine microchannel equipped with embedded barriers
This paper describes the design, simulation, fabrication and experimental analysis of a passive micromixer for the mixing of biological solvents. The mixer consists of a T-junction, followed by a serpentine microchannel. the serpentine has three arcs, each equipped with circular barriers that are patterned as two opposing triangles. >The barriers are engineered to induce periodic perturbations in the flow field and enhance the mixing. CFD (Computational Fluid Dynamics) method is applied to optimise the geometric variables of the mixer before fabrication. The mixer is made from PDMS (Polydimethylsiloxane) using photo- and soft-lithography techniques. Experimental measurements are performed using yellow and blue food dyes as the mixing fluids. The mixing is measured by analysing the composition of the flow\u27s colour across the outlet channel. The performance of the mixer is examined in a wide range of flow rates from 0.5 to 10 µl/min. Mixing efficiencies of higher than 99.4% are obtained in the experiments confirming the results of numerical simulations. The proposed mixer can be employed as a part of lab-on-a-chip for biomedical applications
Miniaturized Embryo Array for Automated Trapping, Immobilization and Microperfusion of Zebrafish Embryos
Zebrafish (Danio rerio) has recently emerged as a powerful experimental model in drug discovery and environmental toxicology. Drug discovery screens performed on zebrafish embryos mirror with a high level of accuracy the tests usually performed on mammalian animal models, and fish embryo toxicity assay (FET) is one of the most promising alternative approaches to acute ecotoxicity testing with adult fish. Notwithstanding this, automated in-situ analysis of zebrafish embryos is still deeply in its infancy. This is mostly due to the inherent limitations of conventional techniques and the fact that metazoan organisms are not easily susceptible to laboratory automation. In this work, we describe the development of an innovative miniaturized chip-based device for the in-situ analysis of zebrafish embryos. We present evidence that automatic, hydrodynamic positioning, trapping and long-term immobilization of single embryos inside the microfluidic chips can be combined with time-lapse imaging to provide real-time developmental analysis. Our platform, fabricated using biocompatible polymer molding technology, enables rapid trapping of embryos in low shear stress zones, uniform drug microperfusion and high-resolution imaging without the need of manual embryo handling at various developmental stages. The device provides a highly controllable fluidic microenvironment and post-analysis eleuthero-embryo stage recovery. Throughout the incubation, the position of individual embryos is registered. Importantly, we also for first time show that microfluidic embryo array technology can be effectively used for the analysis of anti-angiogenic compounds using transgenic zebrafish line (fli1a:EGFP). The work provides a new rationale for rapid and automated manipulation and analysis of developing zebrafish embryos at a large scale
A gallium-based magnetocaloric liquid metal ferrofluid
We demonstrate a magnetocaloric ferrofluid based on a gadolinium saturated liquid metal matrix, using a gallium-based liquid metal alloy as the solvent and suspension medium. The material is liquid at room temperature, while exhibiting spontaneous magnetization and a large magnetocaloric effect. The magnetic properties were attributed to the formation of gadolinium nanoparticles suspended within the liquid gallium alloy, which acts as a reaction solvent during the nanoparticle synthesis. High nanoparticle weight fractions exceeding 2% could be suspended within the liquid metal matrix. The liquid metal ferrofluid shows promise for magnetocaloric cooling due to its high thermal conductivity and its liquid nature. Magnetic and thermoanalytic characterizations reveal that the developed material remains liquid within the temperature window required for domestic refrigeration purposes, which enables future fluidic magnetocaloric devices. Additionally, the observed formation of nanometer-sized metallic particles within the supersaturated liquid metal solution has general implications for chemical synthesis and provides a new synthetic pathway toward metallic nanoparticles based on highly reactive rare earth metals
- …
