499 research outputs found
Smiling makes you look older, even when you wear a mask: the effect of face masks on age perception
The widespread use of face masks in the era of the Covid-19 pandemic has promoted research on their effect on the perception and recognition of faces. There is growing evidence that masks hinder the recognition of identity and expression, as well as the interpretation of speech from facial cues. It is less clear whether and in what manner masks affect the perception of age from facial cues. Recent research has emphasized the role of the upper region of the face, a part not covered by a mask, in the evaluation of age. For example, smile-related wrinkles in the region of the eyes make smiling faces appear older than neutral faces of the same individuals (the aging effect of smiling, AES). In two experiments, we tested the effect of face masks on age evaluations of neutral and smiling faces in a range of different age groups from 20 to 80 years. The results showed that smiling faces were perceived as older than neutral faces even when individuals were wearing a face mask—and there was no effect of masks on bias in age evaluations. Additional analyses showed reduced accuracy in age evaluations for smiling compared to neutral faces and for masked compared to unmasked faces. The results converge on previous studies emphasizing the importance of the upper region of the face in evaluations of age
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission
designed to collect direct data on the elemental composition and individual
energy spectra of cosmic rays. Two instrument suites have been built to be
flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for
the second flight, scheduled for December 2005, was calibrated with electron
and proton beams at CERN. A calibration procedure based on the study of the
longitudinal shower profile is described and preliminary results of the beam
test are presented.Comment: 4 pages, 4 figures. To be published in the Proceedings of 29th
International Cosmic Ray Conference (ICRC 2005), Pune, India, August 3-10,
200
Cosmic-Ray Proton and Helium Spectra from the First CREAM Flight
Cosmic-ray proton and helium spectra have been measured with the
balloon-borne Cosmic Ray Energetics And Mass experiment flown for 42 days in
Antarctica in the 2004-2005 austral summer season. High-energy cosmic-ray data
were collected at an average altitude of ~38.5 km with an average atmospheric
overburden of ~3.9 g cm. Individual elements are clearly separated with
a charge resolution of ~0.15 e (in charge units) and ~0.2 e for protons and
helium nuclei, respectively. The measured spectra at the top of the atmosphere
are represented by power laws with a spectral index of -2.66 0.02 for
protons from 2.5 TeV to 250 TeV and -2.58 0.02 for helium nuclei from 630
GeV/nucleon to 63 TeV/nucleon. They are harder than previous measurements at a
few tens of GeV/nucleon. The helium flux is higher than that expected from the
extrapolation of the power law fitted to the lower-energy data. The relative
abundance of protons to helium nuclei is 9.1 0.5 for the range from 2.5
TeV/nucleon to 63 TeV/nucleon. This ratio is considerably smaller than the
previous measurements at a few tens of GeV/nucleon.Comment: 20 pages, 4 figure
Relative abundances of cosmic ray nuclei B-C-N-O in the energy region from 10 GeV/n to 300 GeV/n. Results from ATIC-2 (the science flight of ATIC)
The ATIC balloon-borne experiment measures the energy spectra of elements
from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is
comprised of a fully active bismuth germanate calorimeter, a carbon target with
embedded scintillator hodoscopes, and a silicon matrix that is used as the main
charge detector. The silicon matrix produces good charge resolution for protons
and helium but only partial resolution for heavier nuclei. In the present
paper, the charge resolution of ATIC was improved and backgrounds were reduced
in the region from Be to Si by using the upper layer of the scintillator
hodoscope as an additional charge detector. The flux ratios of nuclei B/C, C/O,
N/O in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon obtained
from this high-resolution, high-quality charge spectra are presented, and
compared with existing theoretical predictions.Comment: 4 pages,2 figures, a paper for 30-th International Cosmic Rays
Conferenc
Measurements of cosmic-ray energy spectra with the 2nd CREAM flight
During its second Antarctic flight, the CREAM (Cosmic Ray Energetics And
Mass) balloon experiment collected data for 28 days, measuring the charge and
the energy of cosmic rays (CR) with a redundant system of particle
identification and an imaging thin ionization calorimeter. Preliminary direct
measurements of the absolute intensities of individual CR nuclei are reported
in the elemental range from carbon to iron at very high energy.Comment: 4 pages, 3 figures, presented at XV International Symposium on Very
High Energy Cosmic Ray Interactions (ISVHECRI 2008
Elemental energy spectra of cosmic rays measured by CREAM-II
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei
from the second flight of the balloon-borne experiment CREAM (Cosmic Ray
Energetics And Mass). The instrument (CREAM-II) was comprised of detectors
based on different techniques (Cherenkov light, specific ionization in
scintillators and silicon sensors) to provide a redundant charge identification
and a thin ionization calorimeter capable of measuring the energy of cosmic
rays up to several hundreds of TeV. The data analysis is described and the
individual energy spectra of C, O, Ne, Mg, Si and Fe are reported up to ~ 10^14
eV. The spectral shape looks nearly the same for all the primary elements and
can be expressed as a power law in energy E^{-2.66+/-0.04}. The nitrogen
absolute intensity in the energy range 100-800 GeV/n is also measured.Comment: 4 pages, 3 figures, presented at ICRC 2009, Lodz, Polan
Simulation of the ATIC-2 Silicon Matrix for Protons and Helium GCR Primaries at 0.3, 10, and 25 TeV/Nucleon
The energy deposition distribution for protons and helium galactic cosmic ray primaries at 0.3, 10, and 25 TeV/nucleon in the ATIC-2 silicon matrix detector are simulated with GEANT4. The GEANT3 geometrical model of ATIC developed by the University of Maryland was combined with a GEANT4 application developed for the Deep Space Test Bed (DSTB) detector package. The new code included relatively minor modifications to completely describe the ATIC materials and a more detailed model of the Silicon Matrix detector. For this analysis all particles were started as a unidirectional beam at a single point near the center of the Silicon Matrix front surface. The point was selected such that each primary passed through at least two of the overlapping silicon pixels
- …