20 research outputs found

    Analysis of Gender Differences in the Rotational Alignment of the Distal Femur in Kinematically Aligned and Mechanically Aligned Total Knee Arthroplasty

    Get PDF
    To compare the angle between the external rotation references of the femoral components in the axial plane by gender and lower limb alignment in Korean patients with osteoarthritis (OA). Magnetic resonance (MR) images of 1273 patients were imported into a modeling software and segmented to develop three-dimensional femoral bony and cartilaginous models. The surgical transepicondylar axis (sTEA), posterior condylar axis (PCA), the kinematically aligned axis (KAA), and anteroposterior axis were used as rotational references in the axial plane for mechanically aligned (MA) TKA. The relationship among axes were investigated. Among 1273 patients, 942 were female and 331 were male. According to lower limb alignment, the varus and valgus knee groups comprised 848 and 425 patients, respectively. All measurements, except PCA-sTEA, differed significantly between men and women; all measurements, except PCA-sTEA, did not differ significantly between the varus and valgus knee groups. In elderly Korean patients with OA, rotational alignment of the distal femur showed gender differences, but no differences were seen according to lower limb alignment. The concern for malrotation of femoral components during kinematically aligned TKA is less in Koreans than in Caucasians and relatively less in women than in men. In MA TKA, malrotation of the femoral components can be avoided by setting different rotational alignments for the genders.ope

    Gender-Based Quantitative Analysis of the Grand Piano Sign in Mechanically Aligned Total Knee Arthroplasty in Asians

    Get PDF
    In mechanically aligned (MA) total knee arthroplasty (TKA), the grand piano sign helps surgeons to further ensure the proper external rotation of the femoral component. The goal of this study was to determine the sex-related differences in the shape of the anterior resection surface using 3D magnetic resonance imaging (MRI) models. MRI scans were performed on 267 consecutive patients (202 women and 65 men) with osteoarthritis who underwent TKA in order to reconstruct a 3D model. Virtual anterior condylar resection was performed based on the surgical transepicondylar axis (sTEA), Whiteside's line (WSL), and flexion-extension axis (FEA). On the anterior resection surface, both lateral length (LatL) and medial length (MedL) were measured, and the ratio between the two (MedL/LatL) was calculated. The mediolateral width of the distal femur (ML) and anterior resection surface (M'L') were measured, and the ratio between the M'L' and ML (M'L'/ML) was calculated. Both the lateral deviation (LD) and the ratio between LD and ML (LD/ML) were also determined. Morphological classification of the anterior resection surface was conducted based on the presence of a definite medial peak. When based on the sTEA or WSL, the MedL/LatL of female subjects was significantly greater than that of male subjects (p < 0.001 and p < 0.05, respectively). The MedL/LatL of the FEA was consistently larger than that obtained using the sTEA or WSL. Among female subjects, the MedL/LatL of the sTEA was significantly greater than that of the WSL, although this was not the case in either the total study population or the male subjects alone. When based on the sTEA, the M'L'/ML was statistically greater in the female subjects (p < 0.01). The LD was greater in the male subjects (p < 0.01), but there was no difference between the male and female subjects when comparing the LD/ML (p = 0.93). The proportion of double- and single-peak types was not significantly different between the sexes (p = 0.196). Surgeons should be aware that the shape of the anterior resection surface may differ depending on the sex of the patient. The results of this study provide more consistent surgical outcomes as well as fundamental anatomical data for designing suitable prostheses applicable to the Korean population.ope

    Accuracy of 2D CT-Based Measurements of Rotational Alignment of the Femoral Component for Total Knee Arthroplasty

    Get PDF
    Purpose: We aimed to investigate the accuracy of two-dimensional computed tomography (2D-CT)-based methods for measuring rotational alignment of the femoral component during total knee arthroplasty in comparison to reference values for three-dimensional (3D) reconstruction. Materials and methods: We selected the "most protruding transepicondylar axis section," "most protruding posterior condylar line section," and "distal femoral cut section" on 2D-CT images for 100 knees. We investigated posterior condylar angle (PCA) and condylar twist angle (CTA) values using three different methods on 2D-CT and compared to these values to those obtained using a 3D model. Results: The mean PCA and CTA values were 2.8ยฐ and 7.0ยฐ on the 3D model and 2.0ยฐ to 2.1ยฐ and 5.9ยฐ to 6.0ยฐ on 2D-CT, respectively. Errors in PCA and CTA measurement included internal rotation of 0.8ยฐ and 1.1ยฐ with the 1-plane and 2-plane methods and 0.9ยฐ and 1.0ยฐ with the assumed resection method, respectively. Conclusion: Mean errors in PCA and CTA values measured using three different methods on 2D-CT were not significantly different. However, PCA and CTA values measured on 2D-CT were approximately 1ยฐ smaller than their 3D values. Thus, we suggest that adding 1ยฐ to the mean PCA and CTA values obtained from a single plane of 2D-CT would provide values similar to those obtained from 3D reconstruction.ope

    Knee Extension Is Related to the Posteriorly Deviated Gravity Line to the Pelvis in Young Adults: Radiographic Analysis Using Low-Dose Biplanar X-ray

    Get PDF
    Purpose: We sought to compare the radiographic parameters concerning the sagittal alignment of the standing whole-body skeletons between the knee extension group and control group using the low-dose biplanar X-ray system in a young adult population without knee pain, and to investigate the associated variables for the sagittal knee angle (sagKA) among the radiographic parameters of global sagittal alignment. Materials and methods: We reviewed whole-body standing sagittal radiographs of 124 young adults taken from December 2018 to May 2020 in a single institution. We compared the radiographic parameters concerning the lower extremity sagittal alignment and global sagittal alignment between the knee extension group and control group. The factors correlated with sagKA were evaluated using multiple linear regression analysis. Results: The sagittal vertical axis (SVA), the horizontal offset between the gravity line (GL) and the posterior edge of S1 endplate (GL-S), and the horizontal offset between the GL and the hip center (GL-H) were -11.6ยฑ21.3 mm, 5.1ยฑ23.8 mm, and -25.1ยฑ27.1 mm in the knee extension group, respectively, which were significantly smaller than those in the control group. The C7 plumb line (C7PL) and GL were deviated posterior to the sacrum and the hip center in the knee extension group, with the mean sagKA of -5.6ยฐ in young adults. Conclusion: The GL-H using GL, not the SVA using C7PL, was a significant radiographic factor associated with the sagKA.ope

    Biomechanical effect of anatomical tibial component design on load distribution of medial proximal tibial bone in total knee arthroplasty : finite element analysis indicating anatomical design prevents stress-shielding

    Get PDF
    Aims: This study aimed to identify the effect of anatomical tibial component (ATC) design on load distribution in the periprosthetic tibial bone of Koreans using finite element analysis (FEA). Methods: 3D finite element models of 30 tibiae in Korean women were created. A symmetric tibial component (STC, NexGen LPS-Flex) and an ATC (Persona) were used in surgical simulation. We compared the FEA measurements (von Mises stress and principal strains) around the stem tip and in the medial half of the proximal tibial bone, as well as the distance from the distal stem tip to the shortest anteromedial cortical bone. Correlations between this distance and FEA measurements were then analyzed. Results: The distance from the distal stem tip to the shortest cortical bone showed no statistically significant difference between implants. However, the peak von Mises stress around the distal stem tip was higher with STC than with ATC. In the medial half of the proximal tibial bone: 1) the mean von Mises stress, maximum principal strain, and minimum principal strain were higher with ATC; 2) ATC showed a positive correlation between the distance and mean von Mises stress; 3) ATC showed a negative correlation between the distance and mean minimum principal strain; and 4) STC showed no correlation between the distance and mean measurements. Conclusion: Implant design affects the load distribution on the periprosthetic tibial bone, and ATC can be more advantageous in preventing stress-shielding than STC. However, under certain circumstances with short distances, the advantage of ATC may be offset. Cite this article: Bone Joint Res 2022;11(5):252-259.ope

    Cross-Sectional Association between Hypercholesterolemia and Knee Pain in the Elderly with Radiographic Knee Osteoarthritis: Data from the Korean National Health and Nutritional Examination Survey

    Get PDF
    Few studies have reported the relationship between knee pain and hypercholesterolemia in the elderly population with osteoarthritis (OA), independent of other variables. The aim of this study was to reveal the association between knee pain and metabolic diseases including hypercholesterolemia using a large-scale cohort. A cross-sectional study was conducted using data from the Korea National Health and the Nutrition Examination Survey (KNHANES-V, VI-1; 2010-2013). Among the subjects aged โ‰ฅ60 years, 7438 subjects (weighted number estimate = 35,524,307) who replied knee pain item and performed the simple radiographs of knee were enrolled. Using multivariable ordinal logistic regression analysis, variables affecting knee pain were identified, and the odds ratio (OR) was calculated. Of the 35,524,307 subjects, 10,630,836 (29.9%) subjects experienced knee pain. Overall, 20,290,421 subjects (56.3%) had radiographic OA, and 8,119,372 (40.0%) of them complained of knee pain. Multivariable ordinal logistic regression analysis showed that among the metabolic diseases, only hypercholesterolemia was positively correlated with knee pain in the OA group (OR 1.24; 95% Confidence Interval 1.02-1.52, p = 0.033). There were no metabolic diseases correlated with knee pain in the non-OA group. This large-scale study revealed that in the elderly, hypercholesterolemia was positively associated with knee pain independent of body mass index and other metabolic diseases in the OA group, but not in the non-OA group. These results will help in understanding the nature of arthritic pain, and may support the need for exploring the longitudinal associations.ope

    The effect of hamstring tightness on intraoperative extension gap in posterior stabilized total knee arthroplasty

    Get PDF
    This study aimed to determine the factors related to intraoperative extension gap (EG) in patients who underwent posterior-stabilized total knee arthroplasty (TKA). A total of 106 TKAs in 84 patients were retrospectively reviewed. Only patients who underwent the same method of bone resection were included consecutively. Bilateral popliteal angle (BPA) was used as an indicator of hamstring tightness. EG and extension space angle were measured using an offset type tensor. The associations between patient variables and EG were analyzed using multivariable linear regression and Pearson's correlation coefficients. The average EG was 12.9 ยฑ 2.1 mm, and the average extension space angle was 2.8ยฐ ยฑ 3.2ยฐ. BPA was greater than flexion contracture in most cases (94.3%), and no difference was found in only six cases (5.7%). According to multivariable linear regression analysis which was conducted after modifying the BPA into a categorical variable by 5ยฐ, EG was correlated with BPA (p < 0.001). Pearson's correlation coefficient between EG and BPA was - 0.674 (p < 0.001). No other factors were significantly correlated with intraoperative EG. The present study found that popliteal angle is a different entity from flexion contracture, and that it is a predictable factor for EG in osteoarthritis patients. Smaller BPAs led to larger EG in patients who underwent the same degree of bone resection.ope

    Difference between medial and lateral tibia plateau in the coronal plane: importance of preoperative evaluation for medial unicompartmental knee arthroplasty

    Get PDF
    Background: Setting bone cutting levels for different joint line orientations of the medial and lateral tibia plateaus in individual patients is not clear. We aimed to evaluate the difference between joint line orientation of the medial and lateral tibia plateaus relative to the horizontal line of mechanical axis of tibia as tibial plateau difference (TPD) for an optimal tibial bone cut in medial unicompartmental knee arthroplasty (UKA) and determine which factors could influence TPD. We aimed to investigate the effect of preoperative TPD on polyethylene liner size in medial UKA. Methods: TPD in the coronal plane were measured in 181 female patients (181 knees). To determine the morphology of proximal tibia according to the severity of osteoarthritis, the patients were classified into three groups based on diagnosis and treatment: 80 who underwent robot-assisted medial UKA, 45 who underwent total knee arthroplasty (TKA), and 56 with early-stage osteoarthritis (OA) who had conservative management. Also, we divided the medial UKA group into two groups according to TPD (greater than or less than 5 mm) and compared polyethylene liner sizes. Results: No significant difference was observed in TPD (p = 0.662), difference between the medial and lateral femoral condyle levels (p = 0.54), medial proximal tibial angle (p = 0.169), or posterior tibial slope (p = 0.466) among the three groups. Increased TPD was significantly associated with increased mechanical femorotibial angle(mFTA) (p < 0.01). The medial UKA group was divided into two groups according to TPD greater or less than 5 mm. Thicker polyethylene liners were used for groups with TPD greater than 5 mm (8.5 ยฑ 0.7 mm versus 8.2 ยฑ 0.3 mm, p = 0.01). Additionally, the proportion of patients using the thinnest polyethylene (8 mm) in each TPD group (greater or less than 5 mm) was higher in patients with TPD less than 5 mm (82.4% versus 58.7%, p = 0.038). Conclusions: Preoperative measurement of TPD is important to help surgeons predict the most appropriate bone cutting level in the coronal plane in primary medial UKA. Tibial bone resection would be likely to be thicker than needed in patients with increased TPD in medial UKA.ope

    Sex differences in the anatomy of the anterior-superior acetabular rim in relation to pincer-type femoroacetabular impingement in Koreans: a three-dimensional quantitative analysis

    Get PDF
    PURPOSE: The aim of this study was to compare the anatomical structures of the acetabular rim around the anterior inferior iliac spine (AIIS) ridge that indicate anterior focal coverage of acetabulum between the sexes using a three-dimensional (3D) model. METHODS: 3D models of 71 adults (38 men and 33 women) with normal hip joints were used. Based on the location of the inflection point (IP) of the acetabular rim around the AIIS ridge, the patients were classified into anterior and posterior types, and the ratios thereof for each sex were compared. Coordinates for the IP, the most anterior point (MAP), and the most lateral point (MLP) were obtained and compared between the sexes and between anterior and posterior types. RESULTS: Coordinates for IPs in men were located anterior and inferior to those in women. MAP coordinates for men were located inferior to those for women, and MLP coordinates for men were located lateral and inferior to those for women. Comparing AIIS ridge types, we noted that coordinates for IPs of the anterior type were located medial, anterior, and inferior to those of the posterior type. Meanwhile, MAP coordinates of the anterior type were located inferior to those of the posterior type, and MLP coordinates of the anterior type were located lateral and inferior to those of the posterior type. CONCLUSION: Anterior focal coverage of the acetabulum appears to differ between the sexes, and this difference may affect the development of pincer-type femoroacetabular impingement (FAI). Additionally, we found that anterior focal coverage differs according to anterior or posterior positioning of the bony prominence around the AIIS ridge, which may affect development of FAI. ยฉ 2023. The Author(s).ope

    Acetabular labral tear is associated with high pelvic incidence with or without femoroacetabular impingement morphology

    Get PDF
    Purpose: The aim of this study was to investigate the association between pelvic sagittal parameters and acetabular labral tears. Methods: Three-hundred and sixty-five patients (449 hips) who underwent magnetic resonance imaging (MRI) or magnetic resonance arthrogram (MRA) for hip pain were enrolled in this study. Pelvic sagittal parameters, including the pelvic incidence, pelvic tilt, and sacral slope, were measured with a standing lumbosacral lateral radiograph. All subjects were divided into two groups according to the presence or absence of radiologic acetabular labral tears and compared. Furthermore, the two groups were divided into subgroups according to whether femoroacetabular impingement (FAI) morphology was present or not and compared. Results: Pelvic incidence was greater in the labral tear group than in the non-labral tear group (52.3ยฐ ยฑ 8.2ยฐ versus 47.1ยฐ ยฑ 6.8ยฐ, p < 0.001). After accounting for potentially confounding variables, we found that higher age (odds ratio 1.04, 95% confidence interval [CI] 1.02 to 1.06, p = 0.001), FAI (odds ratio 15.11, 95% CI 7.43 to 30.75, p < 0.001), and high pelvic incidence (odds ratio 1.13, 95% CI 1.09 to 1.17, p < 0.001) were independently associated with acetabular labral tear. When only the patients without FAI (308 hips) were divided into groups with and without acetabular labral tear, we found that higher age (odds ratio 1.03, 95% CI 1.01 to 1.06, p = 0.008) and high pelvic incidence (odds ratio 1.15, 95% CI 1.11 to 1.19, p < 0.001) were independently associated with acetabular labral tear. Conclusion: Acetabular labral tear is associated with high pelvic incidence with or without FAI morphology. Level of evidence: III.ope
    corecore