47 research outputs found

    Scoring System to Stratify Malignancy Risks for Mammographic Microcalcifications Based on Breast Imaging Reporting and Data System 5th Edition Descriptors

    Get PDF
    OBJECTIVE: To develop a scoring system stratifying the malignancy risk of mammographic microcalcifications using the 5th edition of the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS: One hundred ninety-four lesions with microcalcifications for which surgical excision was performed were independently reviewed by two radiologists according to the 5th edition of BI-RADS. Each category's positive predictive value (PPV) was calculated and a scoring system was developed using multivariate logistic regression. The scores for benign and malignant lesions or BI-RADS categories were compared using an independent t test or by ANOVA. The area under the receiver operating characteristic curve (AUROC) was assessed to determine the discriminatory ability of the scoring system. Our scoring system was validated using an external dataset. RESULTS: After excision, 69 lesions were malignant (36%). The PPV of BI-RADS descriptors and categories for calcification showed significant differences. Using the developed scoring system, mean scores for benign and malignant lesions or BI-RADS categories were significantly different (p < 0.001). The AUROC of our scoring system was 0.874 (95% confidence interval, 0.840-0.909) and the PPV of each BI-RADS category determined by the scoring system was as follows: category 3 (0%), 4A (6.8%), 4B (19.0%), 4C (68.2%), and 5 (100%). The validation set showed an AUROC of 0.905 and PPVs of 0%, 8.3%, 11.9%, 68.3%, and 94.7% for categories 3, 4A, 4B, 4C, and 5, respectively. CONCLUSION: A scoring system based on BI-RADS morphology and distribution descriptors could be used to stratify the malignancy risk of mammographic microcalcifications.ope

    Shear-wave elastography in breast ultrasonography: the state of the art.

    Get PDF
    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.ope

    3D whole-heart coronary MR angiography at 1.5T in healthy volunteers: comparison between unenhanced SSFP and Gd-enhanced FLASH sequences

    Get PDF
    OBJECTIVE: To validate the optimal cardiac phase and appropriate acquisition window for three-dimensional (3D) whole-heart coronary magnetic resonance angiography (MRA) with a steady-state free precession (SSFP) sequence, and to compare image quality between SSFP and Gd-enhanced fast low-angle shot (FLASH) MR techniques at 1.5 Tesla (T). MATERIALS AND METHODS: Thirty healthy volunteers (M:F = 25:5; mean age, 35 years; range, 24-54 years) underwent a coronary MRA at 1.5T. 3D whole-heart coronary MRA with an SSFP was performed at three different times: 1) at end-systole with a narrow (120-msec) acquisition window (ESN), 2) mid-diastole with narrow acquisition (MDN); and 3) mid-diastole with wide (170-msec) acquisition (MDW). All volunteers underwent a contrast enhanced coronary MRA after undergoing an unenhanced 3D true fast imaging with steady-state precession (FISP) MRA three times. A contrast enhanced coronary MRA with FLASH was performed during MDN. Visibility of the coronary artery and image quality were evaluated for 11 segments, as suggested by the American Heart Association. Image quality was scored by a five-point scale (1 = not visible to 5 = excellent). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated at the proximal coronary arteries. RESULTS: The SSFP sequence rendered higher visibility coronary segments, higher image quality, as well as higher SNR and CNR than the Gd-enhanced FLASH technique at 1.5T (p < 0.05). The visibility of coronary segments, image quality, SNR and CNR in the ESN, MDN and MDW with SSFP sequence did not differ significantly. CONCLUSION: An SSFP sequence provides an excellent method for the 3D whole-heart coronary MRA at 1.5T. Contrast enhanced coronary MRA using the FLASH sequence does not help improve the visibility of coronary segments, image quality, SNR or CNR on the 3D whole-heart coronary MRA.ope

    Comparison of hormonal receptor and HER2 status between ultrasound-guided 14-gauge core needle biopsy and surgery in breast cancer patients

    Get PDF
    PURPOSE: To evaluate the concordance of estrogen receptor, progesterone receptor, and human epidermal growth factor receptor 2 (HER2) statuses between ultrasound (US)-guided 14-gauge core needle biopsy (CNB) and surgery and to analyze whether the clinicopathological and imaging features including those from mammography and ultrasonography can predict the concordance in breast cancer patients. METHODS: The concordance of receptor status between CNB and surgery was assessed for 55 breast cancers in 55 women who underwent CNB before treatment. The clinicopathological and imaging features and the concordance rates were compared between the non-neoadjuvant chemotherapy (non-NAC) group and the NAC group according to the initial treatment. The concordance rates were analyzed according to the clinicopathological and imaging features, by using the chi-square or Fisher exact test and McNemar test for the categorical and the independent t-test for continuous variables. RESULTS: Among 55 women, 22 women (40%) were part of the non-NAC group and 33 women (60%) were part of the NAC group. The concordance rates were 0.86-1.00 in the non-NAC group and 0.76-0.88 in the NAC group. In all three receptors, the difference in the concordance rate between the two groups was not significant. In the NAC group, the absence of axillary lymph node metastasis (1.00, P=0.02) and visibility of cancer on mammography (0.93, P=0.04) showed the higher concordance of the HER2 status. CONCLUSION: Concordance of the receptor status between surgery and US-guided 14-gauge CNB was feasible in breast cancer patients. The absence of axillary lymph node metastasis after NAC and the visibility of cancer on mammography prior to NAC may be helpful for predicting the concordance of HER2 in breast cancer patients.ope

    A convolutional deep learning model for improving mammographic breast-microcalcification diagnosis

    Get PDF
    This study aimed to assess the diagnostic performance of deep convolutional neural networks (DCNNs) in classifying breast microcalcification in screening mammograms. To this end, 1579 mammographic images were collected retrospectively from patients exhibiting suspicious microcalcification in screening mammograms between July 2007 and December 2019. Five pre-trained DCNN models and an ensemble model were used to classify the microcalcifications as either malignant or benign. Approximately one million images from the ImageNet database had been used to train the five DCNN models. Herein, 1121 mammographic images were used for individual model fine-tuning, 198 for validation, and 260 for testing. Gradient-weighted class activation mapping (Grad-CAM) was used to confirm the validity of the DCNN models in highlighting the microcalcification regions most critical for determining the final class. The ensemble model yielded the best AUC (0.856). The DenseNet-201 model achieved the best sensitivity (82.47%) and negative predictive value (NPV; 86.92%). The ResNet-101 model yielded the best accuracy (81.54%), specificity (91.41%), and positive predictive value (PPV; 81.82%). The high PPV and specificity achieved by the ResNet-101 model, in particular, demonstrated the model effectiveness in microcalcification diagnosis, which, in turn, may considerably help reduce unnecessary biopsies.ope

    Quantitative Lesion-to-Fat Elasticity Ratio Measured by Shear-Wave Elastography for Breast Mass: Which Area Should Be Selected as the Fat Reference?

    Get PDF
    OBJECTIVES: To investigate whether the diagnostic performance of lesion-to-fat elasticity ratio (Eratio) was affected by the location of the reference fat. METHODS: For 257 breast masses in 250 women who underwent shear-wave elastography before biopsy or surgery, multiple Eratios were measured with a fixed region-of-interest (ROI) in the mass along with multiple ROIs over the surrounding fat in different locations. Logistic regression analysis was used to determine that Eratio was independently associated with malignancy adjusted for the location of fat ROI (depth, laterality, and distance from lesion or skin). Mean (Emean) and maximum (Emax) elasticity values of fat were divided into four groups according to their interquartile ranges. Diagnostic performance of each group was evaluated using the area under the ROC curve (AUC). False diagnoses of Eratio were reviewed for ROIs on areas showing artifactual high or low stiffness and analyzed by logistic regression analysis to determine variables (associated palpable abnormality, lesion size, the vertical distance from fat ROI to skin, and elasticity values of lesion or fat) independently associated with false results. RESULTS: Eratio was independently associated with malignancy adjusted for the location of fat ROI (P<0.0001). Among four groups of fat elasticity values, the AUC showed no significant difference (<25th percentile, 25th percentile~median, median~75th percentile, and β‰₯75th percentile; 0.973, 0.982, 0.967, and 0.954 for Emean; 0.977, 0.967, 0.966, and 0.957 for Emax). Fat elasticity values were independently associated with false results of Eratio with the cut-off of 3.18 from ROC curve (P<0.0001). ROIs were set on fat showing artifactual high stiffness in 90% of 10 false negatives and on lesion showing vertical striped artifact or fat showing artifactual low stiffness in 77.5% of 71 false positives. CONCLUSION: Eratio shows good diagnostic performance regardless of the location of reference fat, except when it is placed in areas of artifacts.ope

    The clinical significance of accompanying NME on preoperative MR imaging in breast cancer patient

    Get PDF
    PURPOSE: To investigate the significance of accompanying NME in invasive ductal carcinoma (IDC) on preoperative MR imaging and assess the factors affecting the significance. METHODS: Between January 2015 and February 2016, 163 consecutive patients with IDC who underwent preoperative MR imaging and subsequent surgery were enrolled and reviewed. Index cancer mass size and total extent with accompanying NME on MR images was measured and compared with pathologic size. Positive NME was defined as pathological result of IDC or DCIS. To identify affecting factors associated with frequency of accompanying NME on MR and positive pathologic result, clinicopathologic features were compared between breast cancers with NME and without NME, and between breast cancers with positive NME and negative NME using the Student t-test or Chi-square test. RESULTS: Of the 163 invasive breast cancers, 123(75.5%) cancers presented as only mass feature and 40(24.5%) cancers had accompanying NME around the index mass. Of the 40 accompanying NME, 22 (55%) had positive pathologic results and 18 (45%) had negative results. The HER2 positive status was significantly associated with positive pathologic results of accompanying NME (P = .016). CONCLUSION: Accompanying NME on preoperative MR imaging showed malignant pathologic results in 55%. The HER2 positive IDC was more frequently accompanied by malignant NME.ope

    Preoperative Nodal US Features for Predicting Recurrence in N1b Papillary Thyroid Carcinoma

    Get PDF
    This study aimed to investigate whether preoperative ultrasonographic (US) features of metastatic lymph nodes (LNs) are associated with tumor recurrence in patients with N1b papillary thyroid carcinoma (PTC). We enrolled 692 patients (mean age, 41.9 years; range, 6-80 years) who underwent total thyroidectomy and lateral compartment LN dissection between January 2009 and December 2015 and were followed-up for 12 months or longer. Clinicopathologic findings and US features of the index tumor and metastatic LNs in the lateral neck were reviewed. A Kaplan-Meier analysis and Cox proportion hazard model were used to analyze the recurrence-free survival rates and features associated with postoperative recurrence. Thirty-seven (5.3%) patients had developed recurrence at a median follow-up of 66.5 months. On multivariate Cox proportional hazard analysis, male sex (hazard ratio [HR], 2.277; 95% confidence interval [CI]: 1.131, 4.586; p = 0.021), age β‰₯55 years (HR, 3.216; 95% CI: 1.529, 6.766; p = 0.002), LN size (HR, 1.054; 95% CI: 1.024, 1.085; p < 0.001), and hyperechogenicity of LN (HR, 8.223; 95% CI: 1.689, 40.046; p = 0.009) on US were independently associated with recurrence. Preoperative US features of LNs, including size and hyperechogenicity, may be valuable for predicting recurrence in patients with N1b PTC.ope

    Value of the US BI-RADS final assessment following mastectomy: BI-RADS 4 and 5 lesions

    Get PDF
    BACKGROUND: Clinical examination is not entirely sufficient for evaluation of the postoperative site for follow-up of patients with mastectomy. A few studies have reported that postoperative follow-up US evaluation allows early detection and proper management of local tumor recurrence. PURPOSE: To evaluate the diagnostic performance of the American College of Radiology (ACR) ultrasonographic (US) Breast Imaging Reporting and Data System (BI-RADS) categories 4 and 5 breast lesions at the mastectomy site. MATERIAL AND METHODS: Our institutional review board approved this study and waived the need for informed consent. We retrospectively reviewed the consecutive post-mastectomy US exams for palpable and non-palpable lesions in the post-mastectomy chest wall that were categorized as BI-RADS 4 (subcategorized 4a, 4b, and 4c) or 5 between January 2007 and April 2010. The positive predictive value (PPV) for final assessment was evaluated. RESULTS: From 2681 post-mastectomy US examinations, we obtained a study population of 50 patients with 50 lesions (20 palpable, 30 non-palpable). There were nine (45%) malignancies among the palpable lesions and six (20%) malignancies among the non-palpable lesions. The palpability showed no significant correlation with malignancy in overall subcategorization (P >0.05). The PPVs of categories 4 and 5 were 14.3% for category 4a, 62.5% for category 4b, 100% for category 4c, and 100% for category 5. CONCLUSION: The ACR US BI-RADS categorization of 4a, 4b, 4c, and 5 for breast lesions at the mastectomy site is a feasible method for predicting local recurrence. All lesions should be managed according to US characteristics during evaluation of local recurrence at the mastectomy site, regardless of palpability.ope

    Repeat Diagnoses of Bethesda Category III Thyroid Nodules: What To Do Next?

    Get PDF
    OBJECTIVES: To assess the malignancy rates of thyroid nodules repeatedly classified as Bethesda category III on fine needle aspiration (FNA), and to suggest management guidelines for these lesions. METHODS: This is a retrospective study that included 395 thyroid nodules categorized as Bethesda III undergone either surgery or ultrasound (US) follow-up. There were 67 nodules classified a second time as Bethesda category III on repeat FNA. We compared malignancy rates, clinicopathologic and ultrasonographic characteristics between direct surgery and repeat FNA groups and between the initial and repeat Bethesda category III groups, each. And in the repeat Bethesda III group, clinicopathologic and US variables were compared between benign and malignant nodules. RESULTS: Incidence of concurrent cancer, underlying thyroiditis and positive BRAF mutation were significantly higher in 142 nodules with direct surgery than 243 nodules with repeat FNA (p 0.05). In the repeat Bethesda category III group, solid consistency, irregular/microlobulated margins, nonparallel shape, and number of suspicious findings or "suspicious malignant" US assessments were associated with a high malignancy rate (p < 0.05). On multivariate logistic regression analysis, the factor associated with malignancy in the repeat Bethesda category III group was irregular/microlobulated margin (odds ratio = 15.576; 95% CI, 2.097-115.6804, p = 0.007) with a sensitivity, specificity, positive and negative predictive values, and accuracy of 81.6%, 83.3%, 93.0%, 62.5% and 82.1%, respectively. CONCLUSION: Thyroid nodules with repeated Bethesda category III classification and irregular/microlobulated margins on US are at increased risk of malignancy, and operative management should be considered as opposed to repeat FNA.ope
    corecore