2,239 research outputs found

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Ancillary Services in Hybrid AC/DC Low Voltage Distribution Networks

    Get PDF
    In the last decade, distribution systems are experiencing a drastic transformation with the advent of new technologies. In fact, distribution networks are no longer passive systems, considering the current integration rates of new agents such as distributed generation, electrical vehicles and energy storage, which are greatly influencing the way these systems are operated. In addition, the intrinsic DC nature of these components, interfaced to the AC system through power electronics converters, is unlocking the possibility for new distribution topologies based on AC/DC networks. This paper analyzes the evolution of AC distribution systems, the advantages of AC/DC hybrid arrangements and the active role that the new distributed agents may play in the upcoming decarbonized paradigm by providing different ancillary services.Ministerio de Economía y Competitividad ENE2017-84813-RUnión Europea (Programa Horizonte 2020) 76409

    Optimal Phase Swapping in Low Voltage Distribution Networks Based on Smart Meter Data and Optimization Heuristics

    Get PDF
    In this paper a modified version of the Harmony Search algorithm is proposed as a novel tool for phase swapping in Low Voltage Distribution Networks where the objective is to determine to which phase each load should be connected in order to reduce the unbalance when all phases are added into the neutral conductor. Unbalanced loads deteriorate power quality and increase costs of investment and operation. A correct assignment is a direct, effective alternative to prevent voltage peaks and network outages. The main contribution of this paper is the proposal of an optimization model for allocating phases consumers according to their individual consumption in the network of low-voltage distribution considering mono and bi-phase connections using real hourly load patterns, which implies that the computational complexity of the defined combinatorial optimization problem is heavily increased. For this purpose a novel metric function is defined in the proposed scheme. The performance of the HS algorithm has been compared with classical Genetic Algorithm. Presented results show that HS outperforms GA not only on terms of quality but on the convergence rate, reducing the computational complexity of the proposed scheme while provide mono and bi phase connections.This paper includes partial results of the UPGRID project. This project has re- ceived funding from the European Unions Horizon 2020 research and innovation programme under grant agreement No 646.531), for further information check the website: http://upgrid.eu. As well as by the Basque Government through the ELKARTEK programme (BID3A and BID3ABI projects)

    An algorithm for optimal sizing of the capacitor banks under non-sinusoidal and unbalanced conditions

    Get PDF
    In non-sinusoidal and unbalanced systems, optimal sizing of the capacitor banks is not a straightforward task as in sinusoidal and balanced systems. In this paper, by means of qualitative and quantitative analysis, it is interpreted that the classical capacitor selection algorithm widely implemented in Reactive Power Control (RPC) relays does not achieve optimal power factor improvement in non-sinusoidal and unbalanced systems. Accordingly, a computationally efficient algorithm is proposed to find the optimal capacitor bank for smart RPC relays. It is further shown in a simulated test case by using Matlab software that the proposed algorithm provides better power factor improvement when compared with the classical algorithm. It is also figured out from the simulation results that both algorithms cause almost the same harmonic distortion and unbalance deterioration levels in the system

    An Enhanced Power Sharing Scheme for Voltage unbalance and harmonics compensation in an islanded AC microgrid

    Get PDF

    Tertiary Control of Voltage Unbalance Compensation for Optimal Power Quality in Islanded Microgrids

    Get PDF

    Improving the Performance of Low Voltage Networks by an Optimized Unbalance Operation of Three-Phase Distributed Generators

    Get PDF
    This work focuses on using the full potential of PV inverters in order to improve the efficiency of low voltage networks. More specifically, the independent per-phase control capability of PV three-phase four-wire inverters, which are able to inject different active and reactive powers in each phase, in order to reduce the system phase unbalance is considered. This new operational procedure is analyzed by raising an optimization problem which uses a very accurate modelling of European low voltage networks. The paper includes a comprehensive quantitative comparison of the proposed strategy with two state-of-the-art methodologies to highlight the obtained benefits. The achieved results evidence that the proposed independent per-phase control of three-phase PV inverters improves considerably the network performance contributing to increase the penetration of renewable energy sources.Ministerio de Economía y Competitividad ENE2017-84813-R, ENE2014-54115-

    Three-phase primary control for unbalance sharing between distributed generation units in a microgrid

    Get PDF
    For islanded microgrids, droop-based control concepts have been developed both in single and three-phase variants. The three-phase controllers often assume a balanced network, hence, unbalance sharing and/or mitigation remains a challenging issue. Therefore, in this paper, unbalance is considered in a three-phase islanded microgrid where the distributed generation (DG) units are operated by the voltage-based droop (VBD) control. For this purpose, the VBD control, which has been developed for single-phase systems, is extended for three phase application and an additional control loop is added for unbalance mitigation and sharing. The method is based on an unbalance mitigation scheme by DG units in grid-connected systems, which is altered for usage in grid-forming DG units with droop control. The reaction of the DG units to unbalance is determined by the main parameter of the additional control loop, viz, the distortion damping resistance Rd. The effect of Rd on the unbalance mitigation is studied in this paper, i.e., dependent on Rd, the DG units can be resistive for unbalance (RU) or they can contribute in the weakest phase (CW). The paper shows that the RU method decreases the line losses in the system and achieves better power equalization between the DG unit's phases. However, it leads to a larger voltage unbalance near the loads. The CW method leads to a more uneven power between the DG unit's phases and larger line losses, but a better voltage quality near the load. However, it can negatively affect the stability of the system. In microgrids with multiple DG units, the distortion damping resistance is set such that the unbalanced load can be shared between multiple DG units in an actively controlled manner rather than being determined by the microgrid configuration solely. The unit with the lowest distortion resistance provides relatively more of the unbalanced currents
    corecore