Full Reference Objective Quality Assessment for Reconstructed Background Images
With an increased interest in applications that require a clean background
image, such as video surveillance, object tracking, street view imaging and
location-based services on web-based maps, multiple algorithms have been
developed to reconstruct a background image from cluttered scenes.
Traditionally, statistical measures and existing image quality techniques have
been applied for evaluating the quality of the reconstructed background images.
Though these quality assessment methods have been widely used in the past,
their performance in evaluating the perceived quality of the reconstructed
background image has not been verified. In this work, we discuss the
shortcomings in existing metrics and propose a full reference Reconstructed
Background image Quality Index (RBQI) that combines color and structural
information at multiple scales using a probability summation model to predict
the perceived quality in the reconstructed background image given a reference
image. To compare the performance of the proposed quality index with existing
image quality assessment measures, we construct two different datasets
consisting of reconstructed background images and corresponding subjective
scores. The quality assessment measures are evaluated by correlating their
objective scores with human subjective ratings. The correlation results show
that the proposed RBQI outperforms all the existing approaches. Additionally,
the constructed datasets and the corresponding subjective scores provide a
benchmark to evaluate the performance of future metrics that are developed to
evaluate the perceived quality of reconstructed background images.Comment: Associated source code: https://github.com/ashrotre/RBQI, Associated
Database:
https://drive.google.com/drive/folders/1bg8YRPIBcxpKIF9BIPisULPBPcA5x-Bk?usp=sharing
(Email for permissions at: ashrotreasuedu
An Improved Approach for Contrast Enhancement of Spinal Cord Images based on Multiscale Retinex Algorithm
This paper presents a new approach for contrast enhancement of spinal cord
medical images based on multirate scheme incorporated into multiscale retinex
algorithm. The proposed work here uses HSV color space, since HSV color space
separates color details from intensity. The enhancement of medical image is
achieved by down sampling the original image into five versions, namely, tiny,
small, medium, fine, and normal scale. This is due to the fact that the each
versions of the image when independently enhanced and reconstructed results in
enormous improvement in the visual quality. Further, the contrast stretching
and MultiScale Retinex (MSR) techniques are exploited in order to enhance each
of the scaled version of the image. Finally, the enhanced image is obtained by
combining each of these scales in an efficient way to obtain the composite
enhanced image. The efficiency of the proposed algorithm is validated by using
a wavelet energy metric in the wavelet domain. Reconstructed image using
proposed method highlights the details (edges and tissues), reduces image noise
(Gaussian and Speckle) and improves the overall contrast. The proposed
algorithm also enhances sharp edges of the tissue surrounding the spinal cord
regions which is useful for diagnosis of spinal cord lesions. Elaborated
experiments are conducted on several medical images and results presented show
that the enhanced medical pictures are of good quality and is found to be
better compared with other researcher methods.Comment: 13 pages, 6 figures, International Journal of Imaging and Robotics.
arXiv admin note: text overlap with arXiv:1406.571
Recommended from our members
Effect of Time-of-Flight and Regularized Reconstructions on Quantitative Measurements and Qualitative Assessments in Newly Diagnosed Prostate Cancer With 18F-Fluorocholine Dual Time Point PET/MRI.
Recent technical advances in positron emission tomography/magnetic resonance imaging (PET/MRI) technology allow much improved time-of-flight (TOF) and regularized iterative PET reconstruction regularized iterative reconstruction (RIR) algorithms. We evaluated the effect of TOF and RIR on standardized uptake values (maximum and peak SUV [SUVmax and SUVpeak]) and their metabolic tumor volume dependencies and visual image quality for 18F-fluorocholine PET/MRI in patients with newly diagnosed prostate cancer. Fourteen patients were administered with 3 MBq/kg of 18F-fluorocholine and scanned dynamically for 30 minutes. Positron emission tomography images were divided to early and late time points (1-6 minutes summed and 7-30 minutes summed). The values of the different SUVs were documented for dominant PET-avid lesions, and metabolic tumor volume was estimated using a 50% isocontour and SUV threshold of 2.5. Image quality was assessed via visual acuity scoring (VAS). We found that incorporation of TOF or RIR increased lesion SUVs. The lesion to background ratio was not improved by TOF reconstruction, while RIR improved the lesion to background ratio significantly ( P < .05). The values of the different VAS were all significantly higher ( P < .05) for RIR images over TOF, RIR over non-TOF, and TOF over non-TOF. In conclusion, our data indicate that TOF or RIR should be incorporated into current protocols when available
Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography
Iterative image reconstruction algorithms for optoacoustic tomography (OAT),
also known as photoacoustic tomography, have the ability to improve image
quality over analytic algorithms due to their ability to incorporate accurate
models of the imaging physics, instrument response, and measurement noise.
However, to date, there have been few reported attempts to employ advanced
iterative image reconstruction algorithms for improving image quality in
three-dimensional (3D) OAT. In this work, we implement and investigate two
iterative image reconstruction methods for use with a 3D OAT small animal
imager: namely, a penalized least-squares (PLS) method employing a quadratic
smoothness penalty and a PLS method employing a total variation norm penalty.
The reconstruction algorithms employ accurate models of the ultrasonic
transducer impulse responses. Experimental data sets are employed to compare
the performances of the iterative reconstruction algorithms to that of a 3D
filtered backprojection (FBP) algorithm. By use of quantitative measures of
image quality, we demonstrate that the iterative reconstruction algorithms can
mitigate image artifacts and preserve spatial resolution more effectively than
FBP algorithms. These features suggest that the use of advanced image
reconstruction algorithms can improve the effectiveness of 3D OAT while
reducing the amount of data required for biomedical applications
- …