3 research outputs found

    Ultra-thin biocompatible implantable chip for bidirectional communication with peripheral nerves

    Get PDF
    To realize optimal recording and stimulation of peripheral nerve cells, a CMOS chip is made with a multitude of electrodes which can be individually addressed in order to select after implantation the 16 best positioned electrodes. Since the Foreign Body Reaction should be minimal for optimum electrode-nerve contact, the CMOS chip is thinned down to 35um and fully packaged resulting in a 75um thin encapsulated chip. The chip is embedded in a biocompatible stack consisting of polymers and inorganic diffusion barriers deposited using atomic layer deposition (ALD). A biocompatible metallization is realized using gold and platinum sandwiched between polymers and ALD layers for flexible interconnects, and iridium oxide (IrOx) is selected as electrode material for optimal charge injection during stimulation. After this dedicated packaging based on the FITEP technology platform (Flexible Implantable Thin Electronic Package), the CMOS chip is still fully functional, which was tested dry (in air) as well as during submersion in saline. The form factor of the packaged chip is optimized for intra-fascicular implantation with minimum tissue damage. First acute in vivo stimulation tests proved that the stimulation capabilities of the IrOx electrodes are very good

    Accelerated hermeticity testing of biocompatible moisture barriers used for the encapsulation of implantable medical devices

    Get PDF
    Barrier layers for the long-term encapsulation of implantable medical devices play a crucial role in the devices’ performance and reliability. Typically, to understand the stability and predict the lifetime of barriers (therefore, the implantable devices), the device is subjected to accelerated testing at higher temperatures compared to its service parameters. Nevertheless, at high temperatures, reaction and degradation mechanisms might be different, resulting in false accelerated test results. In this study, the maximum valid temperatures for the accelerated testing of two barrier layers were investigated: atomic layer deposited (ALD) Al2O3 and stacked ALD HfO2/Al2O3/HfO2, hereinafter referred to as ALD-3. The in-house developed standard barrier performance test is based on continuous electrical resistance monitoring and microscopic inspection of Cu patterns covered with the barrier and immersed in phosphate buffered saline (PBS) at temperatures up to 95 °C. The results demonstrate the valid temperature window to perform temperature acceleration tests. In addition, the optimized ALD layer in combination with polyimide (polyimide/ALD-3/polyimide) works as effective barrier at 60 °C for 1215 days, suggesting the potential applicability to the encapsulation of long-term implants

    Ultra-long-term reliable encapsulation using an atomic layer deposited Hfo2/Al2o3/Hfo2 triple-interlayer for biomedical implants

    Get PDF
    Long-term packaging of miniaturized, flexible implantable medical devices is essential for the next generation of medical devices. Polymer materials that are biocompatible and flexible have attracted extensive interest for the packaging of implantable medical devices, however realizing these devices with long-term hermeticity up to several years remains a great challenge. Here, polyimide (PI) based hermetic encapsulation was greatly improved by atomic layer deposition (ALD) of a nanoscale-thin, biocompatible sandwich stack of HfO2/Al2O3/HfO2 (ALD-3) between two polyimide layers. A thin copper film covered with a PI/ALD-3/PI barrier maintained excellent electrochemical performance over 1028 days (2.8 years) during acceleration tests at 60 °C in phosphate buffered saline solution (PBS). This stability is equivalent to approximately 14 years at 37 °C. The coatings were monitored in situ through electrochemical impedance spectroscopy (EIS), were inspected by microscope, and were further analyzed using equivalent circuit modeling. The failure mode of ALD Al2O3, ALD-3, and PI soaking in PBS is discussed. Encapsulation using ultrathin ALD-3 combined with PI for the packaging of implantable medical devices is robust at the acceleration temperature condition for more than 2.8 years, showing that it has great potential as reliable packaging for long-term implantable devices
    corecore