    Passive Mixer-based UWB Receiver with Low Loss, High Linearity and Noise-cancelling for Medical Applications

    Get PDF
    A double balanced passive mixer-based receiver operating in the 3-5 GHz UWB for medical applications is described in this paper. The receiver front-end circuit is composed of an inductorless low noise amplifier (LNA) followed by a fully differential voltage-driven double-balanced passive mixer. A duty cycle of 25% was chosen to eliminate overlap between LO signals, thereby improving receiver linearity. The LNA realizes a gain of 25.3 dB and a noise figure of 2.9 dB. The proposed receiver achieves an IIP3 of 3.14 dBm, an IIP2 of 17.5 dBm and an input return loss (S11) below -12.5dB. Designed in 0.18μm CMOS technology, the proposed mixer consumes 0.72pW from a 1.8V power supply. The designed receiver demonstrated a good ports isolation performance with LO_IF isolation of 60dB and RF_IF isolation of 78dB

    A 3.1-4.8GHz IR-UWB All-Digital Pulse Generator in 0.13-um CMOS Technology for WBAN Systems

    Get PDF
    Analog, Digital & RF Circuit DesignImpulse Radio Ultra-WideBand (IR-UWB) systems have drawn growing attention for wireless sensor networks such as Wireless Personal Area Network (WPAN) and Wireless Body Area Network (WBAN) systems ever since the Federal Communications Commission (FCC) released the spectrum between 3.1 and 10.6GHz for unlicensed use in 2002. The restriction on transmitted power spectral density in this band is equal to the noise emission limit of household digital electronics. This band is also shared with several existing service, therefore in-band interference is expected and presents a challenge to UWB system design. UWB devices as secondary spectrum users must also detect and avoid (DAA) other licensed users from the cognitive radio???s point of view. For the DAA requirement, it is more effective to deploy signal with variable center frequency and a minimum 10dB bandwidth of 500MHz than a signal covering the entire UWB spectrum range with fixed center frequency. A key requirement of the applications using IR-UWB signal is ultra-low power consumption for longer battery life. Also, cost reduction is highly desirable. Recently, digital IR-UWB pulse generation is studied more than analog approach due to its lower power consumption. An all-digital pulse generator in a standard 0.13-um CMOS technology for communication systems using Impulse Radio Ultra-WideBand (IR-UWB) signal is presented. A delay line-based architecture utilizing only static logic gates and leading lower power consumption for pulse generation is proposed in this thesis. By using of all-digital architecture, energy is consumed by CV2 switching losses and sub-threshold leakage currents, without RF oscillator or analog bias currents. The center frequency and the fixed bandwidth of 500MHz of the output signal can be digitally controlled to cover three channels in low band of UWB spectrum. Delay based Binary Shift Keying (DB-BPSK) and Pulse Position Modulation (PPM) schemes are exploited at the same time to modulate the transmitted signals with further improvement in spectrum characteristics. The total energy consumption is 48pJ/pulse at 1.2V supply voltage, which is well suitable for WBAN systems.ope

    GigaHertz Symposium 2010

    Get PDF

    RF Integrated Circuits for Energy Autonomous Sensor Nodes.

    Full text link
    The exponential growth in the semiconductor industry has enabled computers to pervade our everyday lives, and as we move forward many of these computers will have form factors much smaller than a typical laptop or smartphone. Sensor nodes will soon be deployed ubiquitously, capable of capturing information of their surrounding environment. The next step is to connect all these different nodes together into an entire interconnected system. This “Internet of Things” (IoT) vision has incredible potential to change our lives commercially, societally, and personally. The backbone of IoT is the wireless sensor node, many of which will operate under very rigorous energy constraints with small batteries or no batteries at all. It has been shown that in sensor nodes, radio communication is one of the biggest bottlenecks to ultra-low power design. This research explores ways to reduce energy consumption in radios for wireless sensor networks, allowing them to run off harvested energy, while maintaining qualities that will allow them to function in a real world, multi-user environment. Three different prototypes have been designed demonstrating these techniques. The first is a sensitivity-reduced nanowatt wake-up radio which allows a sensor node to actively listen for packets even when the rest of the node is asleep. CDMA codes and interference rejection reduce the potential for energy-costly false wake-ups. The second prototype is a full transceiver for a body-worn EKG sensor node. This transceiver is designed to have low instantaneous power and is able to receive 802.15.6 Wireless Body Area Network compliant packets. It uses asymmetric communication including a wake-up receiver based on the previous design, UWB transmitter and a communication receiver. The communication receiver has 10 physical channels to avoid interference and demodulates coherent packets which is uncommon for low power radios, but dictated by the 802.15.6 standard. The third prototype is a long range transceiver capable of >1km communication range in the 433MHz band and able to interface with an existing commercial radio. A digitally assisted baseband demodulator was designed which enables the ability to perform bit-level as well as packet-level duty cycling which increases the radio's energy efficiency.PhDElectrical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/110432/1/nerobert_1.pd

    Electronic bandgap miniaturized UWB antenna for near-field microwave investigation of skin

    Get PDF
    Near-field microwave investigation and tomography has many practical applications, especially where the trend of fields and signals in different environments is vital. This article shows an elliptical patch ultra-wideband antenna fed by a transmission line for the near-field characterization of cancerous cells in the skin. The antenna comprises an elliptical patch, stub loading to shift the band to lower bands, and an electronic bandgap structure on the ground side. Even though the antenna has a low profile of 15 × 15 mm2, the proposed antenna has more promising results than recent studies. Furthermore, both simulated near-field and far-field results show a broad bandwidth of 3.9–30 GHz and a resonance at 2.4 GHz applicable for industrial, scientific, and medical band applications. The proposed antenna also illustrates a peak gain of 6.48 dBi and a peak directivity of 7.09 dBi. Free space and skin (on a layer of breast fat and a tumor with a diameter of 4 mm at the boundary of skin and breast) are used as test environments during the simulation and measurement of near-field and far-field investigations while considering a phantom breast shape. Both far-field and near-field microwave investigations are performed in Computer Simulation Technology studio, and results are then compared with the measured data. The simulated and measured results are in good agreement, and the focused energy around the tumor is completely reconstructed. Therefore, the proposed antenna can be an adequate candidate for the differentiation of breast skin and tumor to reconstruct the tumor’s image

    Full ground ultra-wideband wearable textile antenna for breast cancer and wireless area body network applications

    Get PDF
    Wireless body area network (WBAN) applications have broad utility in monitoring patient health and transmitting the data wirelessly. WBAN can greatly benefit from wearable antennas. Wearable antennas provide comfort and continuity of the monitoring of the patient. Therefore, they must be comfortable, flexible, and operate without excessive degradation near the body. Most wearable antennas use a truncated ground, which increases specific absorption rate (SAR) undesirably. A full ground ultra-wideband (UWB) antenna is proposed and utilized here to attain a broad bandwidth while keeping SAR in the acceptable range based on both 1 g and 10 g standards. It is designed on a denim substrate with a dielectric constant of 1.4 and thickness of 0.7 mm alongside the ShieldIt conductive textile. The antenna is fed using a ground coplanar waveguide (GCPW) through a substrate-integrated waveguide (SIW) transition. This transition creates a perfect match while reducing SAR. In addition, the proposed antenna has a bandwidth (BW) of 7–28 GHz, maximum directive gain of 10.5 dBi and maximum radiation efficiency of 96%, with small dimensions of 60 × 50 × 0.7 mm3. The good antenna’s performance while it is placed on the breast shows that it is a good candidate for both breast cancer imaging and WBAN

    UWB Analog Multiplier in 90nm CMOS SoC Pulse Radar Sensor for Biomedical Applications

    Get PDF
    This thesis reports the description and results of the doctoral research programme in Information Engineering (University of Pisa), carried out in the three years from 2008 to 2010. The doctoral research programme has been originated by the European project ProeTEX aimed at developing a new generation of equipments for the market of emergency operators, like fire-fighters and Civil Protection rescuers. In this context, the multidisciplinary research group originated by the international cooperation of the research groups led by Prof. Danilo De Rossi (University of Pisa, Italy) as for Bio-engineering and Dr. Domenico Zito (University College Cork and Tyndall National Institute, Cork, Ireland) as for Microelectronics, has focused on the implementation of an innovative ultra-wide-band (UWB) pulse radar sensor fully integrated on a single silicon die for non-invasive and contact-less cardio-pulmonary monitoring within a wearable textile sensor platform. The radar sensor is designed to detect the heart and respiratory rates, which can be transmitted to a personal server that coordinates the entire Wireless Body Area Network (WBAN). Such radar sensor should sense the mechanical activity instead of the electrical activity of the heart. UWB bio-sensing allows low risk preliminary monitoring without discomfort since the radar system permits continuous monitoring without requiring any contact with the skin of the patient unlike the traditional technologies (i.e. ultrasounds). In detail, the radar transmits a sequence of extremely short electromagnetic pulses towards the heart and, due to the capability of microwaves to penetrate body tissues, detects the heart wall movement by correlating the echoes reflected with local replicas of the transmitted pulses properly delayed (i.e. time of flight). The specific aim of the doctoral research program has been the design and experimental characterization of the CMOS UWB analog multiplier, which is a crucial circuit in the receiver chain that implements the correlation between the received and amplified echo and the local replica, generated on-chip, of the transmitted pulse. The fully-differential circuit consists of a p-MOSFET common-gate differential pair as input stage for a wideband impedance matching, a p-MOSFET Gilbert’s quad as multiplier stage, and active loads. The circuit has been designed and fabricated in 90nm CMOS. Given the few works on similar analog circuits having inferior performance with respect to those requested, an innovative circuit solution has been identified. Moreover, a novel time-domain metric has been introduced in order to put in evidence the real behaviour of the system that differs from a traditional mixer commonly analyzed using frequency-domain metrics. This new metric, namely Input-Output Energy Ratio (IOER), aims at the optimization of the multiplier circuit design so that the output voltage corresponding to maximum correlation between two input pulses is maximized. The experimental characterization and the comparison with the state of the art have shown that the multiplier exhibits one of the best set of performance available in literature. The novel multiplier has been co-integrated with the other building blocks of the radar. The preliminary experimental characterization of the test-chips carried out by the research group, has demonstrated that the proposed UWB radar sensor works properly. It can detect a reflective target consisting of a half-centimetre-thick board surface (26×26 cm2) covered by aluminium foil, up to a distance of 70 cm. Moreover, it can detect the respiratory rate of a person placed at a distance of 25 cm. This work presents the first implementation, including experimental evidences, of a SoC UWB pulse radar front-end based on a correlation receiver, in 90nm CMOS technology

    Multi-channel ultra-low-power receiver architecture for body area networks

    Get PDF
    Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2011.Cataloged from PDF version of thesis.Includes bibliographical references (p. 85-91).In recently published integrated medical monitoring systems, a common thread is the high power consumption of the radio compared to the other system components. This observation is indicative of a natural place to attempt a reduction in system power. Narrowband receivers in-particular can enjoy significant power reduction by employing high-Q bulk acoustic resonators as channel select filters directly at RF, allowing down-stream analog processing to be simplified, resulting in better energy efficiency. But for communications in the ISM bands, it is important to employ multiple frequency channels to permit frequency-division-multiplexing and provide frequency diversity in the face of narrowband interferers. The high-Q nature of the resonators means that frequency tuning to other channels in the same band is nearly impossible; hence, a new architecture is required to address this challenge. A multi-channel ultra-low power OOK receiver for Body Area Networks (BANs) has been designed and tested. The receiver multiplexes three Film Bulk Acoustic Resonators (FBARs) to provide three channels of frequency discrimination, while at the same time offering competitive sensitivity and superior energy efficiency in this class of BAN receivers. The high-Q parallel resonance of each resonator determines the passband. The resonator's Q is on the order of 1000 and its center frequency is approximately 2.5 GHz, resulting in a -3 dB bandwidth of roughly 2.5 MHz with a very steep rolloff. Channels are selected by enabling the corresponding LNA and mixer pathway with switches, but a key benefit of this architecture is that the switches are not in series with the resonator and do not de-Q the resonance. The measured 1E-3 sensitivity is -64 dBm at 1 Mbps for an energy efficiency of 180 pJ/bit. The resonators are packaged beside the CMOS using wirebonds for the prototype.by Phillip Michel Nadeau.S.M

    Wideband and UWB antennas for wireless applications. A comprehensive review

    Get PDF
    A comprehensive review concerning the geometry, the manufacturing technologies, the materials, and the numerical techniques, adopted for the analysis and design of wideband and ultrawideband (UWB) antennas for wireless applications, is presented. Planar, printed, dielectric, and wearable antennas, achievable on laminate (rigid and flexible), and textile dielectric substrates are taken into account. The performances of small, low-profile, and dielectric resonator antennas are illustrated paying particular attention to the application areas concerning portable devices (mobile phones, tablets, glasses, laptops, wearable computers, etc.) and radio base stations. This information provides a guidance to the selection of the different antenna geometries in terms of bandwidth, gain, field polarization, time-domain response, dimensions, and materials useful for their realization and integration in modern communication systems