1,240 research outputs found
Autonomous Tissue Scanning under Free-Form Motion for Intraoperative Tissue Characterisation
In Minimally Invasive Surgery (MIS), tissue scanning with imaging probes is
required for subsurface visualisation to characterise the state of the tissue.
However, scanning of large tissue surfaces in the presence of deformation is a
challenging task for the surgeon. Recently, robot-assisted local tissue
scanning has been investigated for motion stabilisation of imaging probes to
facilitate the capturing of good quality images and reduce the surgeon's
cognitive load. Nonetheless, these approaches require the tissue surface to be
static or deform with periodic motion. To eliminate these assumptions, we
propose a visual servoing framework for autonomous tissue scanning, able to
deal with free-form tissue deformation. The 3D structure of the surgical scene
is recovered and a feature-based method is proposed to estimate the motion of
the tissue in real-time. A desired scanning trajectory is manually defined on a
reference frame and continuously updated using projective geometry to follow
the tissue motion and control the movement of the robotic arm. The advantage of
the proposed method is that it does not require the learning of the tissue
motion prior to scanning and can deal with free-form deformation. We deployed
this framework on the da Vinci surgical robot using the da Vinci Research Kit
(dVRK) for Ultrasound tissue scanning. Since the framework does not rely on
information from the Ultrasound data, it can be easily extended to other
probe-based imaging modalities.Comment: 7 pages, 5 figures, ICRA 202
Automated pick-up of suturing needles for robotic surgical assistance
Robot-assisted laparoscopic prostatectomy (RALP) is a treatment for prostate
cancer that involves complete or nerve sparing removal prostate tissue that
contains cancer. After removal the bladder neck is successively sutured
directly with the urethra. The procedure is called urethrovesical anastomosis
and is one of the most dexterity demanding tasks during RALP. Two suturing
instruments and a pair of needles are used in combination to perform a running
stitch during urethrovesical anastomosis. While robotic instruments provide
enhanced dexterity to perform the anastomosis, it is still highly challenging
and difficult to learn. In this paper, we presents a vision-guided needle
grasping method for automatically grasping the needle that has been inserted
into the patient prior to anastomosis. We aim to automatically grasp the
suturing needle in a position that avoids hand-offs and immediately enables the
start of suturing. The full grasping process can be broken down into: a needle
detection algorithm; an approach phase where the surgical tool moves closer to
the needle based on visual feedback; and a grasping phase through path planning
based on observed surgical practice. Our experimental results show examples of
successful autonomous grasping that has the potential to simplify and decrease
the operational time in RALP by assisting a small component of urethrovesical
anastomosis
Positive surgical margins in nephron-sparing surgery; the great unknown
There is a currently a general trend towards organ-preserving surgery, and urology is no exception. Specifically, nephron-sparing surgery (NSS) has gained general acceptance for T1a renal cell carcinoma (guidelines recommendations). Moreover T1b, T2 and even T3 stage tumors have been included on the nephron sparing list at some centers. An unresolved issue is that of positive surgical margins (PSM), not only their detection but also the implications for follow up and treatment. This paper highlights data available on risk factors for PSM, their clinical relevance, and possible therapeutic consequences.
From the surgeon’s viewpoint, NSS is a daring and risky surgical procedure. Urological guidelines stress the importance of NSS, and thus the trend is moving in that direction. Unresolved, however, is the problem of PSM. Trifecta, MIC, and pentafecta are applicable concepts which attempt to define the optimal endpoint of NSS, but further elaboration is necessary. Specifically, research needs to focus less on the concept of definitive margins and more on their identification and avoidance. Although some studies suggest that PSMs do not influence overall survival rate, the basic idea of preserving tissue that is not cancerous leads to further medical, social, and psychological considerations
Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical
Robotics have focused on rigid and non deformable anatomical structures.
Nowadays, special attention is paid to soft tissues, raising complex issues due
to their mobility and deformation. Mini-invasive digestive surgery was probably
one of the first fields where soft tissues were handled through the development
of simulators, tracking of anatomical structures and specific assistance
robots. However, other clinical domains, for instance urology, are concerned.
Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU,
radiofrequency, or cryoablation), increasingly early detection of cancer, and
use of interventional and diagnostic imaging modalities, recently opened new
challenges to the urologist and scientists involved in CAMI. This resulted in
the last five years in a very significant increase of research and developments
of computer-aided urology systems. In this paper, we propose a description of
the main problems related to computer-aided diagnostic and therapy of soft
tissues and give a survey of the different types of assistance offered to the
urologist: robotization, image fusion, surgical navigation. Both research
projects and operational industrial systems are discussed
Registration of ultrasound and computed tomography for guidance of laparoscopic liver surgery
Laparoscopic Ultrasound (LUS) imaging is a standard tool used for image-guidance during laparoscopic liver resection, as it provides real-time information on the internal structure of the liver. However, LUS probes are di cult to handle and their resulting images hard to interpret. Additionally, some anatomical targets such as tumours are not always visible, making the LUS guidance less e ective. To solve this problem, registration between the LUS images and a pre-operative Computed Tomography (CT) scan using information from blood vessels has been previously proposed. By merging these two modalities, the relative position between the LUS images and the anatomy of CT is obtained and both can be used to guide the surgeon. The problem of LUS to CT registration is specially challenging, as besides being a multi-modal registration, the eld of view of LUS is signi cantly smaller than that of CT. Therefore, this problem becomes poorly constrained and typically an accurate initialisation is needed. Also, the liver is highly deformed during laparoscopy, complicating the problem further. So far, the methods presented in the literature are not clinically feasible as they depend on manually set correspondences between both images. In this thesis, a solution for this registration problem that may be more transferable to the clinic is proposed. Firstly, traditional registration approaches comprised of manual initialisation and optimisation of a cost function are studied. Secondly, it is demonstrated that a globally optimal registration without a manual initialisation is possible. Finally, a new globally optimal solution that does not require commonly used tracking technologies is proposed and validated. The resulting approach provides clinical value as it does not require manual interaction in the operating room or tracking devices. Furthermore, the proposed method could potentially be applied to other image-guidance problems that require registration between ultrasound and a pre-operative scan
Real-time Prostate Motion Tracking For Robot-assisted Laparoscopic Radical Prostatectomy
Radical prostatectomy surgery (RP) is the gold standard for treatment of localized prostate cancer (PCa). Recently, emergence of minimally invasive techniques such as Laparoscopic Radical Prostatectomy (LRP) and Robot-Assisted Laparoscopic Radical Prostatectomy (RARP) has improved the outcomes for prostatectomy. However, it remains difficult for surgeons to make informed decisions regarding resection margins and nerve sparing since the location of the tumour within the organ is not usually visible in a laparoscopic view. While MRI enables visualization of the salient structures and cancer foci, its efficacy in LRP is reduced unless it is fused into a stereoscopic view such that homologous structures overlap. Registration of the MRI image and peri-operative ultrasound image either via visual manual alignment or using a fully automated registration can potentially be exploited to bring the pre-operative information into alignment with the patient coordinate system at the beginning of the procedure. While doing so, prostate motion needs to be compensated in real-time to synchronize the stereoscopic view with the pre-operative MRI during the prostatectomy procedure. In this thesis, two tracking methods are proposed to assess prostate rigid rotation and translation for the prostatectomy. The first method presents a 2D-to-3D point-to-line registration algorithm to measure prostate motion and translation with respect to an initial 3D TRUS image. The second method investigates a point-based stereoscopic tracking technique to compensate for rigid prostate motion so that the same motion can be applied to the pre-operative images
Ultrasound-Augmented Laparoscopy
Laparoscopic surgery is perhaps the most common minimally invasive procedure for many diseases in the abdomen. Since the laparoscopic camera provides only the surface view of the internal organs, in many procedures, surgeons use laparoscopic ultrasound (LUS) to visualize deep-seated surgical targets. Conventionally, the 2D LUS image is visualized in a display spatially separate from that displays the laparoscopic video. Therefore, reasoning about the geometry of hidden targets requires mentally solving the spatial alignment, and resolving the modality differences, which is cognitively very challenging. Moreover, the mental representation of hidden targets in space acquired through such cognitive medication may be error prone, and cause incorrect actions to be performed.
To remedy this, advanced visualization strategies are required where the US information is visualized in the context of the laparoscopic video. To this end, efficient computational methods are required to accurately align the US image coordinate system with that centred in the camera, and to render the registered image information in the context of the camera such that surgeons perceive the geometry of hidden targets accurately. In this thesis, such a visualization pipeline is described. A novel method to register US images with a camera centric coordinate system is detailed with an experimental investigation into its accuracy bounds. An improved method to blend US information with the surface view is also presented with an experimental investigation into the accuracy of perception of the target locations in space
Video-based assistance system for training in minimally invasive surgery
In this paper, the development of an assisting system for laparoscopic surgical training is presented. With this system, we expect to facilitate the training process at the first stages of training in laparoscopic surgery and to contribute to an objective evaluation of surgical skills. To achieve this, we propose the insertion of multimedia contents and outlines of work adapted to the level of experience of trainees and the detection of the movements of the laparoscopic instrument into the monitored image. A module to track the instrument is implemented focusing on the tip of the laparoscopic tool. This tracking method does not need the presence of artificial marks or special colours to distinguish the instruments. Similarly, the system has another method based on visual tracking to localize support multimedia content in a stable position of the field of vision. Therefore, this position of the support content is adapted to the movements of the camera or the working area. Experimental results are presented to show the feasibility of the proposed system for assisting in laparoscopic surgical training
Performance of image guided navigation in laparoscopic liver surgery – A systematic review
Background:
Compared to open surgery, minimally invasive liver resection has improved short term outcomes. It is however technically more challenging. Navigated image guidance systems (IGS) are being developed to overcome these challenges. The aim of this systematic review is to provide an overview of their current capabilities and limitations.
Methods:
Medline, Embase and Cochrane databases were searched using free text terms and corresponding controlled vocabulary. Titles and abstracts of retrieved articles were screened for inclusion criteria. Due to the heterogeneity of the retrieved data it was not possible to conduct a meta-analysis. Therefore results are presented in tabulated and narrative format.
Results:
Out of 2015 articles, 17 pre-clinical and 33 clinical papers met inclusion criteria. Data from 24 articles that reported on accuracy indicates that in recent years navigation accuracy has been in the range of 8–15 mm. Due to discrepancies in evaluation methods it is difficult to compare accuracy metrics between different systems. Surgeon feedback suggests that current state of the art IGS may be useful as a supplementary navigation tool, especially in small liver lesions that are difficult to locate. They are however not able to reliably localise all relevant anatomical structures. Only one article investigated IGS impact on clinical outcomes.
Conclusions:
Further improvements in navigation accuracy are needed to enable reliable visualisation of tumour margins with the precision required for oncological resections. To enhance comparability between different IGS it is crucial to find a consensus on the assessment of navigation accuracy as a minimum reporting standard
- …