    System Optimization and Iterative Image Reconstruction in Photoacoustic Computed Tomography for Breast Imaging

    Get PDF
    Photoacoustic computed tomography(PACT), also known as optoacoustic tomography (OAT), is an emerging imaging technique that has developed rapidly in recent years. The combination of the high optical contrast and the high acoustic resolution of this hybrid imaging technique makes it a promising candidate for human breast imaging, where conventional imaging techniques including X-ray mammography, B-mode ultrasound, and MRI suffer from low contrast, low specificity for certain breast types, and additional risks related to ionizing radiation. Though significant works have been done to push the frontier of PACT breast imaging, it is still challenging to successfully build a PACT breast imaging system and apply it to wide clinical use because of various practical reasons. First, computer simulation studies are often conducted to guide imaging system designs, but the numerical phantoms employed in most previous works consist of simple geometries and do not reflect the true anatomical structures within the breast. Therefore the effectiveness of such simulation-guided PACT system in clinical experiments will be compromised. Second, it is challenging to design a system to simultaneously illuminate the entire breast with limited laser power. Some heuristic designs have been proposed where the illumination is non-stationary during the imaging procedure, but the impact of employing such a design has not been carefully studied. Third, current PACT imaging systems are often optimized with respect to physical measures such as resolution or signal-to-noise ratio (SNR). It would be desirable to establish an assessing framework where the detectability of breast tumor can be directly quantified, therefore the images produced by such optimized imaging systems are not only visually appealing, but most informative in terms of the tumor detection task. Fourth, when imaging a large three-dimensional (3D) object such as the breast, iterative reconstruction algorithms are often utilized to alleviate the need to collect densely sampled measurement data hence a long scanning time. However, the heavy computation burden associated with iterative algorithms largely hinders its application in PACT breast imaging. This dissertation is dedicated to address these aforementioned problems in PACT breast imaging. A method that generates anatomically realistic numerical breast phantoms is first proposed to facilitate computer simulation studies in PACT. The non-stationary illumination designs for PACT breast imaging are then systematically investigated in terms of its impact on reconstructed images. We then apply signal detection theory to assess different system designs to demonstrate how an objective, task-based measure can be established for PACT breast imaging. To address the slow computation time of iterative algorithms for PACT imaging, we propose an acceleration method that employs an approximated but much faster adjoint operator during iterations, which can reduce the computation time by a factor of six without significantly compromising image quality. Finally, some clinical results are presented to demonstrate that the PACT breast imaging can resolve most major and fine vascular structures within the breast, along with some pathological biomarkers that may indicate tumor development

    Toward Realistic and Practical Ideal Observer (IO) Estimation for the Optimization of Medical Imaging Systems

    No full text

    RIGOROUS TASK-BASED OPTIMIZATION OF INSTRUMENTATION, ACQUISITION PARAMETERS AND RECONSTRUCTION METHODS FOR MYOCARDIAL PERFUSION SPECT

    Get PDF
    Coronary artery disease (CAD) is the most common type of heart disease and a major cause of death in the United States. Myocardial perfusion SPECT (MPS) is a well-established noninvasive diagnostic imaging technique for the detection and functional characterization of CAD. MPS involves intravenous injection of a radiopharmaceutical (e.g. Tc-99m sestamibi) followed by acquiring planar images of the 3-D distribution of the radioactive labeled agent, using one or more gamma cameras that are rotated around the patient, at different projection views. Transaxial reconstructed images are formed from these projections using tomographic image reconstruction methods. The quality of SPECT images is affected by instrumentation, acquisition parameters and reconstruction/compensation methods used. The overall goal of this dissertation was to perform rigorous optimization of MPS using task-based image quality assessment methods and metrics, in which image quality is evaluated based on the performance of an observer on diagnostic tasks relevant to MPS. In this work, we used three different model observers: the Ideal Observer (IO), and its extension, the Ideal Observer with Model Mismatch (IO-MM) and an anthropomorphic observer, the Channelized Hotelling Observer (CHO). The IO makes optimal use of the available information in the image data. However, due to its implicit perfect knowledge about the image formation process, using the IO to optimize imaging systems could lead to differences in optimal parameters compared to those optimized for humans (or CHO) interpreting images that are reconstructed with imperfect compensation for image-degrading factors. To address this, we developed the IO-MM that allows optimization of acquisition and instrumentation parameters in the absence of compensation or the presence of non-ideal compensation methods and evaluates them in terms of the IO. In order to perform clinically relevant optimization of MPS and due to radiation concerns that limit system evaluation using patient studies, we designed and developed a population of digital phantoms based on the 3-D eXtended CArdiac Torso (XCAT) phantom that provides an extremely realistic model of the human anatomy. To make the simulation of the population computationally feasible, we developed and used methods to efficiently simulate a database of Tc-99m and Tl-201 MPS projections using full Monte Carlo (MC) simulations. We used the phantom population and the projection database to optimize and evaluate the major acquisition and instrumentation parameters for MPS. An important acquisition parameter is the width of the acquisition energy window, which controls the tradeoff between scatter and noise. We used the IO, IO–MM and CHO to find the optimal acquisition energy window width and evaluate various scatter modeling and compensation methods, including the dual and triple energy window and the Effective Source Scatter Estimation (ESSE). Results indicated that the ESSE scatter estimation method provided very similar performance to the perfect scatter model implicit in the IO. Collimators are a major factor limiting image quality and largely determine the noise and resolution of SPECT images. We sought the optimal collimator with respect to the IO performance on two tasks related to MPS: binary detection and joint detection and localization. The results of this study suggested that higher sensitivity collimators than those currently used clinically appear optimal for both of the diagnostic tasks. In a different study, we evaluated and compared various CDR modeling and compensation methods using the IO (i.e. the observer implicitly used a true CDR model), IO-MM (using an approximate or no model of the CDR) and CHO, operating on images reconstructed using the same compensation methods. Results from the collimator and acquisition energy window optimization studies indicated that the IO-MM had good agreement with the CHO, in terms of the range of optimal Tc-99m acquisition energy window widths, optimal collimators, and the ranking of scatter and CDR compensation methods. The IO was in agreement with the CHO when model mismatch was small. Dual isotope simultaneous acquisition (DISA) rest Tl-201/stress Tc-99m MPS has the potential to provide reduced acquisition time, increased patient comfort, and perfectly registered images compared to separate acquisition protocols, the current clinical protocols of choice. However, crosstalk contamination, where photons emitted by one radionuclide contribute to the image of the other, degrades image quality. In this work, we optimized, compared and evaluated dual isotope MPS imaging with separate and simultaneous acquisition using the IO in the context of 3-class defect detection task. Optimal acquisition parameters were different for the two protocols. Results suggested that DISA methods, when used with accurate crosstalk compensation methods, could potentially provide image quality as good as that obtained with separate acquisition protocols
    corecore