232 research outputs found

    A Markov Random Field Based Approach to 3D Mosaicing and Registration Applied to Ultrasound Simulation

    Get PDF
    A novel Markov Random Field (MRF) based method for the mosaicing of 3D ultrasound volumes is presented in this dissertation. The motivation for this work is the production of training volumes for an affordable ultrasound simulator, which offers a low-cost/portable training solution for new users of diagnostic ultrasound, by providing the scanning experience essential for developing the necessary psycho-motor skills. It also has the potential for introducing ultrasound instruction into medical education curriculums. The interest in ultrasound training stems in part from the widespread adoption of point-of-care scanners, i.e. low cost portable ultrasound scanning systems in the medical community. This work develops a novel approach for producing 3D composite image volumes and validates the approach using clinically acquired fetal images from the obstetrics department at the University of Massachusetts Medical School (UMMS). Results using the Visible Human Female dataset as well as an abdominal trauma phantom are also presented. The process is broken down into five distinct steps, which include individual 3D volume acquisition, rigid registration, calculation of a mosaicing function, group-wise non-rigid registration, and finally blending. Each of these steps, common in medical image processing, has been investigated in the context of ultrasound mosaicing and has resulted in improved algorithms. Rigid and non-rigid registration methods are analyzed in a probabilistic framework and their sensitivity to ultrasound shadowing artifacts is studied. The group-wise non-rigid registration problem is initially formulated as a maximum likelihood estimation, where the joint probability density function is comprised of the partially overlapping ultrasound image volumes. This expression is simplified using a block-matching methodology and the resulting discrete registration energy is shown to be equivalent to a Markov Random Field. Graph based methods common in computer vision are then used for optimization, resulting in a set of transformations that bring the overlapping volumes into alignment. This optimization is parallelized using a fusion approach, where the registration problem is divided into 8 independent sub-problems whose solutions are fused together at the end of each iteration. This method provided a speedup factor of 3.91 over the single threaded approach with no noticeable reduction in accuracy during our simulations. Furthermore, the registration problem is simplified by introducing a mosaicing function, which partitions the composite volume into regions filled with data from unique partially overlapping source volumes. This mosaicing functions attempts to minimize intensity and gradient differences between adjacent sources in the composite volume. Experimental results to demonstrate the performance of the group-wise registration algorithm are also presented. This algorithm is initially tested on deformed abdominal image volumes generated using a finite element model of the Visible Human Female to show the accuracy of its calculated displacement fields. In addition, the algorithm is evaluated using real ultrasound data from an abdominal phantom. Finally, composite obstetrics image volumes are constructed using clinical scans of pregnant subjects, where fetal movement makes registration/mosaicing especially difficult. Our solution to blending, which is the final step of the mosaicing process, is also discussed. The trainee will have a better experience if the volume boundaries are visually seamless, and this usually requires some blending prior to stitching. Also, regions of the volume where no data was collected during scanning should have an ultrasound-like appearance before being displayed in the simulator. This ensures the trainee\u27s visual experience isn\u27t degraded by unrealistic images. A discrete Poisson approach has been adapted to accomplish these tasks. Following this, we will describe how a 4D fetal heart image volume can be constructed from swept 2D ultrasound. A 4D probe, such as the Philips X6-1 xMATRIX Array, would make this task simpler as it can acquire 3D ultrasound volumes of the fetal heart in real-time; However, probes such as these aren\u27t widespread yet. Once the theory has been introduced, we will describe the clinical component of this dissertation. For the purpose of acquiring actual clinical ultrasound data, from which training datasets were produced, 11 pregnant subjects were scanned by experienced sonographers at the UMMS following an approved IRB protocol. First, we will discuss the software/hardware configuration that was used to conduct these scans, which included some custom mechanical design. With the data collected using this arrangement we generated seamless 3D fetal mosaics, that is, the training datasets, loaded them into our ultrasound training simulator, and then subsequently had them evaluated by the sonographers at the UMMS for accuracy. These mosaics were constructed from the raw scan data using the techniques previously introduced. Specific training objectives were established based on the input from our collaborators in the obstetrics sonography group. Important fetal measurements are reviewed, which form the basis for training in obstetrics ultrasound. Finally clinical images demonstrating the sonographer making fetal measurements in practice, which were acquired directly by the Philips iU22 ultrasound machine from one of our 11 subjects, are compared with screenshots of corresponding images produced by our simulator

    A Markov Random Field Based Approach to 3D Mosaicing and Registration Applied to Ultrasound Simulation

    Get PDF
    A novel Markov Random Field (MRF) based method for the mosaicing of 3D ultrasound volumes is presented in this dissertation. The motivation for this work is the production of training volumes for an affordable ultrasound simulator, which offers a low-cost/portable training solution for new users of diagnostic ultrasound, by providing the scanning experience essential for developing the necessary psycho-motor skills. It also has the potential for introducing ultrasound instruction into medical education curriculums. The interest in ultrasound training stems in part from the widespread adoption of point-of-care scanners, i.e. low cost portable ultrasound scanning systems in the medical community. This work develops a novel approach for producing 3D composite image volumes and validates the approach using clinically acquired fetal images from the obstetrics department at the University of Massachusetts Medical School (UMMS). Results using the Visible Human Female dataset as well as an abdominal trauma phantom are also presented. The process is broken down into five distinct steps, which include individual 3D volume acquisition, rigid registration, calculation of a mosaicing function, group-wise non-rigid registration, and finally blending. Each of these steps, common in medical image processing, has been investigated in the context of ultrasound mosaicing and has resulted in improved algorithms. Rigid and non-rigid registration methods are analyzed in a probabilistic framework and their sensitivity to ultrasound shadowing artifacts is studied. The group-wise non-rigid registration problem is initially formulated as a maximum likelihood estimation, where the joint probability density function is comprised of the partially overlapping ultrasound image volumes. This expression is simplified using a block-matching methodology and the resulting discrete registration energy is shown to be equivalent to a Markov Random Field. Graph based methods common in computer vision are then used for optimization, resulting in a set of transformations that bring the overlapping volumes into alignment. This optimization is parallelized using a fusion approach, where the registration problem is divided into 8 independent sub-problems whose solutions are fused together at the end of each iteration. This method provided a speedup factor of 3.91 over the single threaded approach with no noticeable reduction in accuracy during our simulations. Furthermore, the registration problem is simplified by introducing a mosaicing function, which partitions the composite volume into regions filled with data from unique partially overlapping source volumes. This mosaicing functions attempts to minimize intensity and gradient differences between adjacent sources in the composite volume. Experimental results to demonstrate the performance of the group-wise registration algorithm are also presented. This algorithm is initially tested on deformed abdominal image volumes generated using a finite element model of the Visible Human Female to show the accuracy of its calculated displacement fields. In addition, the algorithm is evaluated using real ultrasound data from an abdominal phantom. Finally, composite obstetrics image volumes are constructed using clinical scans of pregnant subjects, where fetal movement makes registration/mosaicing especially difficult. Our solution to blending, which is the final step of the mosaicing process, is also discussed. The trainee will have a better experience if the volume boundaries are visually seamless, and this usually requires some blending prior to stitching. Also, regions of the volume where no data was collected during scanning should have an ultrasound-like appearance before being displayed in the simulator. This ensures the trainee\u27s visual experience isn\u27t degraded by unrealistic images. A discrete Poisson approach has been adapted to accomplish these tasks. Following this, we will describe how a 4D fetal heart image volume can be constructed from swept 2D ultrasound. A 4D probe, such as the Philips X6-1 xMATRIX Array, would make this task simpler as it can acquire 3D ultrasound volumes of the fetal heart in real-time; However, probes such as these aren\u27t widespread yet. Once the theory has been introduced, we will describe the clinical component of this dissertation. For the purpose of acquiring actual clinical ultrasound data, from which training datasets were produced, 11 pregnant subjects were scanned by experienced sonographers at the UMMS following an approved IRB protocol. First, we will discuss the software/hardware configuration that was used to conduct these scans, which included some custom mechanical design. With the data collected using this arrangement we generated seamless 3D fetal mosaics, that is, the training datasets, loaded them into our ultrasound training simulator, and then subsequently had them evaluated by the sonographers at the UMMS for accuracy. These mosaics were constructed from the raw scan data using the techniques previously introduced. Specific training objectives were established based on the input from our collaborators in the obstetrics sonography group. Important fetal measurements are reviewed, which form the basis for training in obstetrics ultrasound. Finally clinical images demonstrating the sonographer making fetal measurements in practice, which were acquired directly by the Philips iU22 ultrasound machine from one of our 11 subjects, are compared with screenshots of corresponding images produced by our simulator

    Retrieval and Registration of Long-Range Overlapping Frames for Scalable Mosaicking of In Vivo Fetoscopy

    Get PDF
    Purpose: The standard clinical treatment of Twin-to-Twin Transfusion Syndrome consists in the photo-coagulation of undesired anastomoses located on the placenta which are responsible to a blood transfer between the two twins. While being the standard of care procedure, fetoscopy suffers from a limited field-of-view of the placenta resulting in missed anastomoses. To facilitate the task of the clinician, building a global map of the placenta providing a larger overview of the vascular network is highly desired. Methods: To overcome the challenging visual conditions inherent to in vivo sequences (low contrast, obstructions or presence of artifacts, among others), we propose the following contributions: (i) robust pairwise registration is achieved by aligning the orientation of the image gradients, and (ii) difficulties regarding long-range consistency (e.g. due to the presence of outliers) is tackled via a bag-of-word strategy, which identifies overlapping frames of the sequence to be registered regardless of their respective location in time. Results: In addition to visual difficulties, in vivo sequences are characterised by the intrinsic absence of gold standard. We present mosaics motivating qualitatively our methodological choices and demonstrating their promising aspect. We also demonstrate semi-quantitatively, via visual inspection of registration results, the efficacy of our registration approach in comparison to two standard baselines. Conclusion: This paper proposes the first approach for the construction of mosaics of placenta in in vivo fetoscopy sequences. Robustness to visual challenges during registration and long-range temporal consistency are proposed, offering first positive results on in vivo data for which standard mosaicking techniques are not applicable.Comment: Accepted for publication in International Journal of Computer Assisted Radiology and Surgery (IJCARS

    Multi-View 3D Transesophageal Echocardiography Registration and Volume Compounding for Mitral Valve Procedure Planning

    Get PDF
    Three-dimensional ultrasound mosaicing can increase image quality and expand the field of view. However, limited work has been done applying these compounded approaches for cardiac procedures focused on the mitral valve. For procedures targeting the mitral valve, transesophageal echocardiography (TEE) is the primary imaging modality used as it provides clear 3D images of the valve and surrounding tissues. However, TEE suffers from image artefacts and signal dropout, particularly for structures lying below the valve, including chordae tendineae, making it necessary to acquire alternative echo views to visualize these structures. Due to the limited field of view obtainable, the entire ventricle cannot be directly visualized in sufficient detail from a single image acquisition in 3D. We propose applying an image compounding technique to TEE volumes acquired from a mid-esophageal position and several transgastric positions in order to reconstruct a high-detail volume of the mitral valve and sub-valvular structures. This compounding technique utilizes both fully and semi-simultaneous group-wise registration to align the multiple 3D volumes, followed by a weighted intensity compounding step based on the monogenic signal. This compounding technique is validated using images acquired from two excised porcine mitral valve units and three patient data sets. We demonstrate that this compounding technique accurately captures the physical structures present, including the mitral valve, chordae tendineae and papillary muscles. The chordae length measurement error between the compounded ultrasound and ground-truth CT for two porcine valves is reported as 0.7 ± 0.6 mm and 0.6 ± 0.6 mm

    EchoFusion: Tracking and Reconstruction of Objects in 4D Freehand Ultrasound Imaging without External Trackers

    Get PDF
    Ultrasound (US) is the most widely used fetal imaging technique. However, US images have limited capture range, and suffer from view dependent artefacts such as acoustic shadows. Compounding of overlapping 3D US acquisitions into a high-resolution volume can extend the field of view and remove image artefacts, which is useful for retrospective analysis including population based studies. However, such volume reconstructions require information about relative transformations between probe positions from which the individual volumes were acquired. In prenatal US scans, the fetus can move independently from the mother, making external trackers such as electromagnetic or optical tracking unable to track the motion between probe position and the moving fetus. We provide a novel methodology for image-based tracking and volume reconstruction by combining recent advances in deep learning and simultaneous localisation and mapping (SLAM). Tracking semantics are established through the use of a Residual 3D U-Net and the output is fed to the SLAM algorithm. As a proof of concept, experiments are conducted on US volumes taken from a whole body fetal phantom, and from the heads of real fetuses. For the fetal head segmentation, we also introduce a novel weak annotation approach to minimise the required manual effort for ground truth annotation. We evaluate our method qualitatively, and quantitatively with respect to tissue discrimination accuracy and tracking robustness.Comment: MICCAI Workshop on Perinatal, Preterm and Paediatric Image analysis (PIPPI), 201

    A Log-Euclidean and Total Variation based Variational Framework for Computational Sonography

    Get PDF
    We propose a spatial compounding technique and variational framework to improve 3D ultrasound image quality by compositing multiple ultrasound volumes acquired from different probe orientations. In the composite volume, instead of intensity values, we estimate a tensor at every voxel. The resultant tensor image encapsulates the directional information of the underlying imaging data and can be used to generate ultrasound volumes from arbitrary, potentially unseen, probe positions. Extending the work of Hennersperger et al., we introduce a log-Euclidean framework to ensure that the tensors are positive-definite, eventually ensuring non-negative images. Additionally, we regularise the underpinning ill-posed variational problem while preserving edge information by relying on a total variation penalisation of the tensor field in the log domain. We present results on in vivo human data to show the efficacy of the approach.Comment: SPIE Medical Imaging 201

    Autonomous Tissue Scanning under Free-Form Motion for Intraoperative Tissue Characterisation

    Full text link
    In Minimally Invasive Surgery (MIS), tissue scanning with imaging probes is required for subsurface visualisation to characterise the state of the tissue. However, scanning of large tissue surfaces in the presence of deformation is a challenging task for the surgeon. Recently, robot-assisted local tissue scanning has been investigated for motion stabilisation of imaging probes to facilitate the capturing of good quality images and reduce the surgeon's cognitive load. Nonetheless, these approaches require the tissue surface to be static or deform with periodic motion. To eliminate these assumptions, we propose a visual servoing framework for autonomous tissue scanning, able to deal with free-form tissue deformation. The 3D structure of the surgical scene is recovered and a feature-based method is proposed to estimate the motion of the tissue in real-time. A desired scanning trajectory is manually defined on a reference frame and continuously updated using projective geometry to follow the tissue motion and control the movement of the robotic arm. The advantage of the proposed method is that it does not require the learning of the tissue motion prior to scanning and can deal with free-form deformation. We deployed this framework on the da Vinci surgical robot using the da Vinci Research Kit (dVRK) for Ultrasound tissue scanning. Since the framework does not rely on information from the Ultrasound data, it can be easily extended to other probe-based imaging modalities.Comment: 7 pages, 5 figures, ICRA 202

    Enhanced Ultrasound Visualization for Procedure Guidance

    Get PDF
    Intra-cardiac procedures often involve fast-moving anatomic structures with large spatial extent and high geometrical complexity. Real-time visualization of the moving structures and instrument-tissue contact is crucial to the success of these procedures. Real-time 3D ultrasound is a promising modality for procedure guidance as it offers improved spatial orientation information relative to 2D ultrasound. Imaging rates at 30 fps enable good visualization of instrument-tissue interactions, far faster than the volumetric imaging alternatives (MR/CT). Unlike fluoroscopy, 3D ultrasound also allows better contrast of soft tissues, and avoids the use of ionizing radiation.Engineering and Applied Science

    Spatial calibration of a 2D/3D ultrasound using a tracked needle

    Get PDF
    PURPOSE: Spatial calibration between a 2D/3D ultrasound and a pose tracking system requires a complex and time-consuming procedure. Simplifying this procedure without compromising the calibration accuracy is still a challenging problem. METHOD: We propose a new calibration method for both 2D and 3D ultrasound probes that involves scanning an arbitrary region of a tracked needle in different poses. This approach is easier to perform than most alternative methods that require a precise alignment between US scans and a calibration phantom. RESULTS: Our calibration method provides an average accuracy of 2.49 mm for a 2D US probe with 107 mm scanning depth, and an average accuracy of 2.39 mm for a 3D US with 107 mm scanning depth. CONCLUSION: Our method proposes a unified calibration framework for 2D and 3D probes using the same phantom object, work-flow, and algorithm. Our method significantly improves the accuracy of needle-based methods for 2D US probes as well as extends its use for 3D US probes