6,921 research outputs found

    Partial discharge behavior under HVDC superimposed with transients

    Get PDF

    Identifying harmonic attributes from online partial discharge data

    Get PDF
    Partial discharge (PD) monitoring is a key method of tracking fault progression and degradation of insulation systems. Recent research discovered that the harmonic regime experienced by the plant also affects the PD pattern, questioning the conclusions about equipment health drawn from PD data. This paper presents the design and creation of an online system for harmonic circumstance monitoring of distribution cables, using only PD data. Based on machine learning techniques, the system can assess the prevalence of the 5th and 7th harmonic orders over the monitoring period. This information is key for asset managers to draw correct conclusions about the remaining life of polymeric cable insulation, and prevent overestimation of the degradation trend

    Partial discharge behavior under operational and anomalous conditions in HVDC systems

    Get PDF
    Power cables undergo various types of overstressing conditions during their operation that influence the integrity of their insulation systems. This causes accelerated ageing and might lead to their premature failure in severe cases. This paper presents an investigation of the impacts of various dynamic electric fields produced by ripples, polarity reversal and transient switching impulses on partial discharge (PD) activity within solid dielectrics with the aim of considering such phenomena in high voltage direct current (HVDC) cable systems. Appropriate terminal voltages of a generic HVDC converter were reproduced - with different harmonic contaminations - and applied to the test samples. The effects of systematic operational polarity reversal and superimposed switching impulses with the possibility of transient polarity reversal were also studied in this investigation. The experimental results show that the PD is greatly affected by the dynamic changes of electric field represented by polarity reversal, ripples and switching. The findings of this study will assist in understanding the behaviour of PDs under HVDC conditions and would be of interest to asset managers considering the effects of such conditions on the insulation diagnostics

    Time domain analysis of switching transient fields in high voltage substations

    Get PDF
    Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within the substations. The radiated fields may interfere and disrupt normal operations of electronic equipment used within the substation for measurement, control and communication purposes. Hence there is the need to fully characterise the substation electromagnetic environment as early as the design stage of substation planning and operation to ensure safe operations of the electronic equipment. This paper deals with the computation of transient electromagnetic fields due to switching within a high voltage air-insulated substation (AIS) using the finite difference time domain (FDTD) metho

    Optimized power converters for electrically augmented on-orbit propulsion systems

    Full text link
    Advances in satellite thruster technology have produced the requirement for high power electrical supplies to operate electrically augmented on-orbit propulsion systems. The power on board satellites is greatly limited by the solar panels that collect energy and the batteries that store the energy. In addition, satellites are constantly using power to operated their mission equipment and handle the communication requirements; This thesis investigates the power systems of modern satellites and the addition of an on-orbit electrically augmented propulsion system. The research process involves determining the system specifications, the power available and the thruster requirements. After determining the requirements, the implementation of the electrically augmented on-orbit propulsion system is characterized in terms of efficiency and potential electromagnetic compatibility. Several circuits are evaluated with the aid of PSPICE circuit simulation software and the results of the evaluation criteria for each circuit are presented

    Inductively coupled probe for the measurement of partial discharges

    Get PDF
    Partial discharges are a transient phenomena whose measurement is remarkably important for electrical equipment diagnosis and maintenance. These discharges appear in the measurement circuit as very narrow current pulses of some nanoseconds. Therefore, discharge pulse detection is a particularly difficult problem, especially because they are superposed on the high voltage waveforms that cause them. In this paper, we present an inductively coupled probe able to measure this physical phenomenon by means of a very simple and inexpensive device that can be installed. in the equipment under test. After modeling the probe, its response will be compared to that of commercial devices using both calibrated discharges and partial discharges occurring at real powerThis research has been supported by the Spanish Science and Technology Ministry DPI 2006-15625-C03-02

    Effect of water on electrical properties of Refined, Bleached, and Deodorized Palm Oil (RBDPO) as electrical insulating material

    Get PDF
    This paper describes the properties of refined, bleached, deodorized palm oil (RBDPO) as having the potential to be used as insulating liquid. There are several important properties such as electrical breakdown, dielectric dissipation factor, specific gravity, flash point, viscosity and pour point of RBDPO that was measured and compared to commercial mineral oil which is largely in current use as insulating liquid in power transformers. Experimental results of the electrical properties revealed that the average breakdown voltage of the RBDPO sample, without the addition of water at room temperature, is 13.368 kV. The result also revealed that due to effect of water, the breakdown voltage is lower than that of commercial mineral oil (Hyrax). However, the flash point and the pour point of RBDPO is very high compared to mineral oil thus giving it advantageous possibility to be used safely as insulating liquid. The results showed that RBDPO is greatly influenced by water, causing the breakdown voltage to decrease and the dissipation factor to increase; this is attributable to the high amounts of dissolved water

    On-line Partial Discharge Localization of 10-kV Covered Conductor Lines

    Get PDF
    This paper proposes an innovative partial discharge (PD) location technique for overhead electrical power distribution networks. It is aimed at improving the condition-based maintenance of the network. PD localization is carried out via an improved double-sided traveling-wave method. The method is driven by a hybrid detection technique, which integrates a pulse-based synchronization mechanism and a global positioning system (GPS). The proposed solution offers a number of benefits. It has the nice inherent feature of being immune to varying physical parameters of the transmission line, and it has been proven be offer improved accuracy with respect of the conventional GPS-based location methods. Also, an in-house designed portable and non-invasive test setup is presented and thoroughly discussed, thus demonstrating the feasibility of the proposed method. Moreover, an enhanced algorithm is embedded into the PD location system to improve robustness to high-level noise. Finally, the proposed tool relies on a well-established automatic procedure which requires neither parameter tuning nor any expert intervention. The features and strengths of the method are validated on a real case consisting of a 2125-m long 10-kV overhead covered conductor line