2,780 research outputs found

    A review of contemporary techniques for measuring ergonomic wear comfort of protective and sport clothing

    Get PDF
    Protective and sport clothing is governed by protection requirements, performance, and comfort of the user. The comfort and impact performance of protective and sport clothing are typically subjectively measured, and this is a multifactorial and dynamic process. The aim of this review paper is to review the contemporary methodologies and approaches for measuring ergonomic wear comfort, including objective and subjective techniques. Special emphasis is given to the discussion of different methods, such as objective techniques, subjective techniques, and a combination of techniques, as well as a new biomechanical approach called modeling of skin. Literature indicates that there are four main techniques to measure wear comfort: subjective evaluation, objective measurements, a combination of subjective and objective techniques, and computer modeling of human–textile interaction. In objective measurement methods, the repeatability of results is excellent, and quantified results are obtained, but in some cases, such quantified results are quite different from the real perception of human comfort. Studies indicate that subjective analysis of comfort is less reliable than objective analysis because human subjects vary among themselves. Therefore, it can be concluded that a combination of objective and subjective measuring techniques could be the valid approach to model the comfort of textile materials

    The status of textile-based dry EEG electrodes

    Get PDF
    Electroencephalogram (EEG) is the biopotential recording of electrical signals generated by brain activity. It is useful for monitoring sleep quality and alertness, clinical applications, diagnosis, and treatment of patients with epilepsy, disease of Parkinson and other neurological disorders, as well as continuous monitoring of tiredness/ alertness in the field. We provide a review of textile-based EEG. Most of the developed textile-based EEGs remain on shelves only as published research results due to a limitation of flexibility, stickability, and washability, although the respective authors of the works reported that signals were obtained comparable to standard EEG. In addition, nearly all published works were not quantitatively compared and contrasted with conventional wet electrodes to prove feasibility for the actual application. This scenario would probably continue to give a publication credit, but does not add to the growth of the specific field, unless otherwise new integration approaches and new conductive polymer composites are evolved to make the application of textile-based EEG happen for bio-potential monitoring

    Wearable smart textiles for long-term electrocardiography monitoring : a review

    Get PDF
    The continuous and long-term measurement and monitoring of physiological signals such as electrocardiography (ECG) are very important for the early detection and treatment of heart disorders at an early stage prior to a serious condition occurring. The increasing demand for the continuous monitoring of the ECG signal needs the rapid development of wearable electronic technology. During wearable ECG monitoring, the electrodes are the main components that affect the signal quality and comfort of the user. This review assesses the application of textile electrodes for ECG monitoring from the fundamentals to the latest developments and prospects for their future fate. The fabrication techniques of textile electrodes and their performance in terms of skin–electrode contact impedance, motion artifacts and signal quality are also reviewed and discussed. Textile electrodes can be fabricated by integrating thin metal fiber during the manufacturing stage of textile products or by coating textiles with conductive materials like metal inks, carbon mate-rials, or conductive polymers. The review also discusses how textile electrodes for ECG function via direct skin contact or via a non-contact capacitive coupling. Finally, the current intensive and promising research towards finding textile-based ECG electrodes with better comfort and signal quality in the fields of textile, material, medical and electrical engineering are presented as a perspective

    Wearable Sensors and Smart Devices to Monitor Rehabilitation Parameters and Sports Performance: An Overview

    Get PDF
    A quantitative evaluation of kinetic parameters, the joint’s range of motion, heart rate, and breathing rate, can be employed in sports performance tracking and rehabilitation monitoring following injuries or surgical operations. However, many of the current detection systems are expensive and designed for clinical use, requiring the presence of a physician and medical staff to assist users in the device’s positioning and measurements. The goal of wearable sensors is to overcome the limitations of current devices, enabling the acquisition of a user’s vital signs directly from the body in an accurate and non–invasive way. In sports activities, wearable sensors allow athletes to monitor performance and body movements objectively, going beyond the coach’s subjective evaluation limits. The main goal of this review paper is to provide a comprehensive overview of wearable technologies and sensing systems to detect and monitor the physiological parameters of patients during post–operative rehabilitation and athletes’ training, and to present evidence that supports the efïŹcacy of this technology for healthcare applications. First, a classiïŹcation of the human physiological parameters acquired from the human body by sensors attached to sensitive skin locations or worn as a part of garments is introduced, carrying important feedback on the user’s health status. Then, a detailed description of the electromechanical transduction mechanisms allows a comparison of the technologies used in wearable applications to monitor sports and rehabilitation activities. This paves the way for an analysis of wearable technologies, providing a comprehensive comparison of the current state of the art of available sensors and systems. Comparative and statistical analyses are provided to point out useful insights for deïŹning the best technologies and solutions for monitoring body movements. Lastly, the presented review is compared with similar ones reported in the literature to highlight its strengths and novelties

    Bio-sensing textile based patch with integrated optical detection system for sweat monitoring

    Get PDF
    Sensors, which can be integrated into clothing and used to measure biochemical changes in body fluids, such as sweat, constitute a major advancement in the area of wearable sensors. Initial applications for such technology exist in personal health and sports performance monitoring. However, sample collection is a complicated matter as analysis must be done in real-time in order to obtain a useful examination of its composition. This work outlines the development of a textile-based fluid handling platform which uses a passive pump to gather sweat and move it through a pre-defined channel for analysis. The system is tested both in vitro and in vivo. In addition, a pH sensor, which depends on the use of a pH sensitive dye and paired emitter-detector LEDs to measure colour changes, has been developed. In vitro and on-body trials have shown that the sensor has the potential to record real-time variations in sweat during exercise

    InMyFace: Inertial and Mechanomyography-Based Sensor Fusion for Wearable Facial Activity Recognition

    Full text link
    Recognizing facial activity is a well-understood (but non-trivial) computer vision problem. However, reliable solutions require a camera with a good view of the face, which is often unavailable in wearable settings. Furthermore, in wearable applications, where systems accompany users throughout their daily activities, a permanently running camera can be problematic for privacy (and legal) reasons. This work presents an alternative solution based on the fusion of wearable inertial sensors, planar pressure sensors, and acoustic mechanomyography (muscle sounds). The sensors were placed unobtrusively in a sports cap to monitor facial muscle activities related to facial expressions. We present our integrated wearable sensor system, describe data fusion and analysis methods, and evaluate the system in an experiment with thirteen subjects from different cultural backgrounds (eight countries) and both sexes (six women and seven men). In a one-model-per-user scheme and using a late fusion approach, the system yielded an average F1 score of 85.00% for the case where all sensing modalities are combined. With a cross-user validation and a one-model-for-all-user scheme, an F1 score of 79.00% was obtained for thirteen participants (six females and seven males). Moreover, in a hybrid fusion (cross-user) approach and six classes, an average F1 score of 82.00% was obtained for eight users. The results are competitive with state-of-the-art non-camera-based solutions for a cross-user study. In addition, our unique set of participants demonstrates the inclusiveness and generalizability of the approach.Comment: Submitted to Information Fusion, Elsevie

    Challenges in Design and Fabrication of Flexible/Stretchable Carbon- and Textile-Based Wearable Sensors for Health Monitoring: A Critical Review

    Get PDF
    To demonstrate the wearable flexible/stretchable health-monitoring sensor, it is necessary to develop advanced functional materials and fabrication technologies. Among the various developed materials and fabrication processes for wearable sensors, carbon-based materials and textile-based configurations are considered as promising approaches due to their outstanding characteristics such as high conductivity, lightweight, high mechanical properties, wearability, and biocompatibility. Despite these advantages, in order to realize practical wearable applications, electrical and mechanical performances such as sensitivity, stability, and long-term use are still not satisfied. Accordingly, in this review, we describe recent advances in process technologies to fabricate advanced carbon-based materials and textile-based sensors, followed by their applications such as human activity and electrophysiological sensors. Furthermore, we discuss the remaining challenges for both carbon- and textile-based wearable sensors and then suggest effective strategies to realize the wearable sensors in health monitoring

    The era of nano-bionic: 2D materials for wearable and implantable body sensors

    Get PDF
    Nano-bionics have the potential of revolutionizing modern medicine. Among nano-bionic devices, body sensors allow to monitor in real-time the health of patients, to achieve personalized medicine, and even to restore or enhance human functions. The advent of two-dimensional (2D) materials is facilitating the manufacturing of miniaturized and ultrathin bioelectronics, that can be easily integrated in the human body. Their unique electronic properties allow to efficiently transduce physical and chemical stimuli into electric current. Their flexibility and nanometric thickness facilitate the adaption and adhesion to human body. The low opacity permits to obtain transparent devices. The good cellular adhesion and reduced cytotoxicity are advantageous for the integration of the devices in vivo. Herein we review the latest and more significant examples of 2D material-based sensors for health monitoring, describing their architectures, sensing mechanisms, advantages and, as well, the challenges and drawbacks that hampers their translation into commercial clinical devices
    • 

    corecore