5,555 research outputs found
Mixed Valvular Disease Following Transcatheter Aortic Valve Replacement: Quantification and Systematic Differentiation Using Clinical Measurements and Image-Based Patient‐Specific In Silico Modeling
Background: Mixed valvular disease (MVD), mitral regurgitation (MR) from pre‐existing disease in conjunction with paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR), is one of the most important stimuli for left ventricle (LV) dysfunction, associated with cardiac mortality. Despite the prevalence of MVD, the quantitative understanding of the interplay between pre‐existing MVD, PVL, LV, and post‐TAVR recovery is meager.
Methods and Results: We quantified the effects of MVD on valvular‐ventricular hemodynamics using an image‐based patient‐specific computational framework in 72 MVD patients. Doppler pressure was reduced by TAVR (mean, 77%; N=72; P<0.05), but it was not always accompanied by improvements in LV workload. TAVR had no effect on LV workload in 22 patients, and LV workload post‐TAVR significantly rose in 32 other patients. TAVR reduced LV workload in only 18 patients (25%). PVL significantly alters LV flow and increases shear stress on transcatheter aortic valve leaflets. It interacts with mitral inflow and elevates shear stresses on mitral valve and is one of the main contributors in worsening of MR post‐TAVR. MR worsened in 32 patients post‐TAVR and did not improve in 18 other patients.
Conclusions: PVL limits the benefit of TAVR by increasing LV load and worsening of MR and heart failure. Post‐TAVR, most MVD patients (75% of N=72; P<0.05) showed no improvements or even worsening of LV workload, whereas the majority of patients with PVL, but without that pre‐existing MR condition (60% of N=48; P<0.05), showed improvements in LV workload. MR and its exacerbation by PVL may hinder the success of TAVR
Improved costs and outcomes with conscious sedation vs general anesthesia in TAVR patients: Time to wake up?
BackgroundTranscatheter aortic valve replacement (TAVR) has become a commonplace procedure for the treatment of aortic stenosis in higher risk surgical patients. With the high cost and steadily increasing number of patients receiving TAVR, emphasis has been placed on optimizing outcomes as well as resource utilization. Recently, studies have demonstrated the feasibility of conscious sedation in lieu of general anesthesia for TAVR. This study aimed to investigate the clinical as well as cost outcomes associated with conscious sedation in comparison to general anesthesia in TAVR.MethodsRecords for all adult patients undergoing TAVR at our institution between August 2012 and June 2016 were included using our institutional Society of Thoracic Surgeons (STS) and American College of Cardiology (ACC) registries. Cost data was gathered using the BIOME database. Patients were stratified into two groups according to whether they received general anesthesia (GA) or conscious sedation (CS) during the procedure. No-replacement propensity score matching was done using the validated STS predicted risk of mortality (PROM) as a propensity score. Primary outcome measure with survival to discharge and several secondary outcome measures were also included in analysis. According to our institution's data reporting guidelines, all cost data is presented as a percentage of the general anesthesia control group cost.ResultsOf the 231 patients initially identified, 225 (157 GA, 68 CS) were included for analysis. After no-replacement propensity score matching, 196 patients (147 GA, 49 CS) remained. Overall mortality was 1.5% in the matched population with a trend towards lower mortality in the CS group. Conscious sedation was associated with significantly fewer ICU hours (30 vs 96 hours, p = <0.001) and total hospital days (4.9 vs 10.4, p<0.001). Additionally, there was a 28% decrease in direct cost (p<0.001) as well as significant decreases in all individual all cost categories associated with the use of conscious sedation. There was no difference in composite major adverse events between groups. These trends remained on all subsequent subgroup analyses.ConclusionConscious sedation is emerging as a safe and viable option for anesthesia in patients undergoing transcatheter aortic valve replacement. The use of conscious sedation was not only associated with similar rates of adverse events, but also shortened ICU and overall hospital stays. Finally, there were significant decreases in all cost categories when compared to a propensity matched cohort receiving general anesthesia
Possible predicative role of electrical risk score on transcatheter aortic valve replacement outcomes in older patients. preliminary data
Background:Transcatheter aortic valve replacement (TAVR) is an effective procedure capable to change the natural history of the degenerative aortic valve stenosis. Despite the TAVR, the patients with advanced valve disease and severe myocardial damage (low flow, gradient and ejection fraction)show high mortality level. Aim of this study was toevaluate the predicative power of a noninvasive and inexpensive test obtained by means of a simple standard 12-leads electrocardiogram,known as the Electrical Risk Score (ERS).
Methods: ERS was composed by seven simple ECG markers: heart rate (>75 bpm); QRS duration (>110 ms), left ventricular hypertrophy (Sokolow-Lyon criteria), delayed QRS transition zone (≥ V4), frontal QRS-T angle (>90°), long QTBazett (>450 ms for men and >460 in women) or JTBazett(330 ms for men and > 340 ms for women);long T peak to T end interval (Tp-e)( >89 ms). An ERS ≥ 4was considered high risk for all-cause or cardiovascular mortality.We calculated retrospectively the pre-procedure ERS in 40 TAVR patients after one year of follow-up.
Results: In the follow up the all-cause and cardiovascular mortality were respectively 25% and 15%.None of survivors reported ERS ≥ 4,moreover, the ERS was the strongest predictor of all-cause (odd ratio 3.73, 95% CI: 1.44-9.66, p<0.05) or cardiovascular (odd ratio 3.95, 95% CI: 1.09-14.27, p<0.05) mortality.ROC curves showed that ERS had the widest significant sensitivity-specificity area under the curve (auc) predicting all-cause (auc: 0.855, p<0.05) or cardiovascular mortality (auc: 0.908, p<0.05).
Conclusions:In this pivotal study, ERS resulted an useful tool to stratify the risk of mortality in one-year follow-up TAVR patients. Obviously, it is necessary to confirm these data in large prospective studies
Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves
To the Editor: Makkar et al. (Nov. 19 issue)(1) report possible subclinical leaflet thrombosis in up to 40% of patients involved in a clinical trial of transcatheter aortic-valve replacement (TAVR). In contrast, we found a relatively low incidence (7%) of possible subclinical valve leaflet thrombosis among patients in our series in which 255 patients underwent TAVR with the use of a CoreValve prosthesis. A retrospective review of our series (unpublished data) showed that in 104 patients, cardiac computed tomography (CT) at a median of 7 days after implantation (range, 3 to 87) (in 51 patients), transesophageal echocardiography at a median . .
Generative Invertible Networks (GIN): Pathophysiology-Interpretable Feature Mapping and Virtual Patient Generation
Machine learning methods play increasingly important roles in pre-procedural
planning for complex surgeries and interventions. Very often, however,
researchers find the historical records of emerging surgical techniques, such
as the transcatheter aortic valve replacement (TAVR), are highly scarce in
quantity. In this paper, we address this challenge by proposing novel
generative invertible networks (GIN) to select features and generate
high-quality virtual patients that may potentially serve as an additional data
source for machine learning. Combining a convolutional neural network (CNN) and
generative adversarial networks (GAN), GIN discovers the pathophysiologic
meaning of the feature space. Moreover, a test of predicting the surgical
outcome directly using the selected features results in a high accuracy of
81.55%, which suggests little pathophysiologic information has been lost while
conducting the feature selection. This demonstrates GIN can generate virtual
patients not only visually authentic but also pathophysiologically
interpretable
Intermediate-Term Risk of Stroke Following Cardiac Procedures in a Nationally Representative Data Set.
BACKGROUND: Studies on stroke risk following cardiac procedures addressed only perioperative and long-term risk following limited higher-risk procedures, were poorly generalizable, and often failed to stratify by stroke type. We calculated stroke risk in the intermediate risk period following cardiac procedures compared with common noncardiac surgeries and medical admissions.
METHODS AND RESULTS: The Nationwide Readmissions Database contains readmission data for 49% of US admissions in 2013. We compared age-adjusted stroke readmission rates up to 90 days postdischarge. We used Cox regression to calculate hazard ratios, up to 1 year, of stroke risk comparing transcatheter aortic valve replacement versus surgical aortic valve replacement and coronary artery bypass graft versus percutaneous coronary intervention. Procedures and diagnoses were identified by International Classification of Disease, Ninth Revision, Clinical Modification codes. After cardiac procedures, 90-day ischemic stroke readmission rate was highest after transcatheter aortic valve replacement (2.05%); 90-day hemorrhagic stroke rate was highest after left ventricular assist device placement (0.09%). The hazard ratio for ischemic stroke after transcatheter aortic valve replacement, compared with surgical aortic valve replacement, in fully adjusted Cox models was 1.86 (95% confidence interval, 1.12-3.08; P=0.016) and 6.17 (95% confidence interval, 1.97-19.33; P=0.0018) for hemorrhagic stroke. There was no difference between coronary artery bypass graft and percutaneous coronary intervention.
CONCLUSIONS: We demonstrated elevated readmission rates for ischemic and hemorrhagic stroke in the intermediate 30-, 60-, and 90-day risk periods following common cardiac procedures. Furthermore, we found an elevated risk of stroke after transcatheter aortic valve replacement compared with surgical aortic valve replacement up to 1 year
Bridging aortic valve surgery to 21st century. what can a surgeon do
Aortic valve stenosis is the most clinically relevant valvular heart disease in the elderlies. Surgical aortic valve replacement (SAVR) represented, for decades, the standard of care for the treatment of severe aortic stenosis. Although SAVR still represents a valid option in this clinical scenario, transcatheter aortic valve implantation proved to be superior to medical therapy and comparable to SAVR in several randomized trials in patients at high or intermediate operative risk. At the same time, the growing aging population carrying on greater morbidities and high risk profiles has led to the development of minimally invasive technologies, as rapid deployment aortic valve replacement or Sutureless, to minimize surgical impact on patients. The Heart Team is nowadays tasked to determine the best option tailored for each patient considering patient-related factors and mastering all the surgical options in terms of both different techniques and types of available valves. Nevertheless, some open issues need to be already answered as: which has the longest durability, which the lower complication rate and the lower overall mortality. The aim of this review is to briefly resume the main features of these different options and explore what kind of open questions these newer-generation prosthetic valves and delivery devices carry
Electrocardiographic repolarization-related variables as predictors of coronary heart disease death in the women's health initiative study.
BackgroundWe evaluated 25 repolarization-related ECG variables for the risk of coronary heart disease (CHD) death in 52 994 postmenopausal women from the Women's Health Initiative study.Methods and resultsHazard ratios from Cox regression were computed for subgroups of women with and without cardiovascular disease (CVD). During the average follow-up of 16.9 years, 941 CHD deaths occurred. Based on electrophysiological considerations, 2 sets of ECG variables with low correlations were considered as candidates for independent predictors of CHD death: Set 1, Ѳ(Tp|Tref), the spatial angle between T peak (Tp) and normal T reference (Tref) vectors; Ѳ(Tinit|Tterm), the angle between the initial and terminal T vectors; STJ depression in V6 and rate-adjusted QTp interval (QTpa); and Set 2, TaVR and TV1 amplitudes, heart rate, and QRS duration. Strong independent predictors with over 2-fold increased risk for CHD death in women with and without CVD were Ѳ(Tp|Tref) >42° from Set 1 and TaVR amplitude >-100 μV from Set 2. The risk for these CHD death predictors remained significant after multivariable adjustment for demographic/clinical factors. Other significant predictors for CHD death in fully adjusted risk models were Ѳ(Tinit|Tterm) >30°, TV1 >175 μV, and QRS duration >100 ms.ConclusionsѲ(Tp|Tref) angle and TaVR amplitude are associated with CHD mortality in postmenopausal women. The use of these measures to identify high-risk women for further diagnostic evaluation or more intense preventive intervention warrants further study.Clinical trial registration urlhttp://www.clinicaltrials.gov. Unique identifier: NCT00000611
Arrhythmic risk in elderly patients candidates to transcatheter aortic valve replacement. predicative role of repolarization temporal dispersion
Degenerative aortic valve stenosis (AS) is associated to ventricular arrhythmias and sudden cardiac death, as well as mental stress in specific patients. In such a context, substrate, autonomic imbalance as well as repolarization dispersion abnormalities play an undoubted role. Aim of the study was to evaluate the increase of premature ventricular contractions (PVC) and complex ventricular arrhythmias during mental stress in elderly patients candidate to the transcatheter aortic valve replacement (TAVR). In eighty-one elderly patients with AS we calculated several short-period RRand QT-derived variables at rest, during controlled breathing and during mild mental stress, the latter being represented by a mini-mental state evaluation (MMSE). All the myocardial repolarization dispersion markers worsened during mental stress (p < 0.05). Furthermore, during MMSE, low frequency component of the RR variability increased significantly both as absolute power (LFRR) and normalized units (LFRRNU) (p < 0.05) as well as the low-high frequency ratio (LFRR/HFRR) (p < 0.05). Eventually, twenty-four (30%) and twelve (15%) patients increased significantly PVC and, respectively, complex ventricular arrhythmias during the MMSE administration. At multivariate logistic regression analysis, the standard deviation of QTend (QTesd), obtained at rest, was predictive of increased PVC (odd ratio: 1.54, 95% CI 1.14–2.08; p = 0.005) and complex ventricular arrhythmias (odd ratio: 2.31, 95% CI 1.40–3.83; p = 0.001) during MMSE. The QTesd showed the widest sensitive-specificity area under the curve for the increase of PVC (AUC: 0.699, 95% CI: 0.576–0.822, p < 0.05) and complex ventricular arrhythmias (AUC: 0.801, 95% CI: 0.648–0.954, p < 0.05). In elderly with AS ventricular arrhythmias worsened during a simple cognitive assessment, this events being a possible further burden on the outcome of TAVR. QTesd might be useful to identify those patients with the highest risk of ventricular arrhythmias. Whether the TAVR could led to a QTesd reduction and, hence, to a reductionof thearrhythmicburdenin thissettingofpatients isworthytobe investigated
- …