2,935 research outputs found
(e,2e) measurements on xeon: reexamination of the fine-structure effect
The process of electron scattering from heavy target atoms is of considerable interest due to the enhanced
role of relativistic effects and distortion of the electron trajectories resulting from the large value of nuclear
charge. Here we present (e,2e) ionization measurements and distorted-wave Born approximation calculations
for the scattering of spin-polarized electrons from xenon atoms in which the fine-structure levels of the residual
ion are resolved. Comparison of measurements performed using a high-sensitivity toroidal analyzer spectrometer
with the predictions of sophisticated calculations provide an improved understanding of the ionization
dynamics of heavy target atoms and the treatment of electron exchange processes
A high-efficiency spin-resolved phototemission spectrometer combining time-of-flight spectroscopy with exchange-scattering polarimetry
We describe a spin-resolved electron spectrometer capable of uniquely
efficient and high energy resolution measurements. Spin analysis is obtained
through polarimetry based on low-energy exchange scattering from a
ferromagnetic thin-film target. This approach can achieve a similar analyzing
power (Sherman function) as state-of-the-art Mott scattering polarimeters, but
with as much as 100 times improved efficiency due to increased reflectivity.
Performance is further enhanced by integrating the polarimeter into a
time-of-flight (TOF) based energy analysis scheme with a precise and flexible
electrostatic lens system. The parallel acquisition of a range of electron
kinetic energies afforded by the TOF approach results in an order of magnitude
(or more) increase in efficiency compared to hemispherical analyzers. The lens
system additionally features a 90{\deg} bandpass filter, which by removing
unwanted parts of the photoelectron distribution allows the TOF technique to be
performed at low electron drift energy and high energy resolution within a wide
range of experimental parameters. The spectrometer is ideally suited for
high-resolution spin- and angle-resolved photoemission spectroscopy
(spin-ARPES), and initial results are shown. The TOF approach makes the
spectrometer especially ideal for time-resolved spin-ARPES experiments.Comment: 16 pages, 11 figure
(e,2e) Measurements on Xenon: Reexamination of the Fine-Structure Effect
The process of electron scattering from heavy target atoms is of considerable interest due to the enhanced role of relativistic effects and distortion of the electron trajectories resulting from the large value of nuclear charge. Here we present (e,2e) ionization measurements and distorted-wave Born approximation calculations for the scattering of spin-polarized electrons from xenon atoms in which the fine-structure levels of the residual ion are resolved. Comparison of measurements performed using a high-sensitivity toroidal analyzer spectrometer with the predictions of sophisticated calculations provide an improved understanding of the ionization dynamics of heavy target atoms and the treatment of electron exchange processes
Fluctuation analysis: can estimates be trusted?
The estimation of mutation probabilities and relative fitnesses in
fluctuation analysis is based on the unrealistic hypothesis that the
single-cell times to division are exponentially distributed. Using the
classical Luria-Delbr\"{u}ck distribution outside its modelling hypotheses
induces an important bias on the estimation of the relative fitness. The model
is extended here to any division time distribution. Mutant counts follow a
generalization of the Luria-Delbr\"{u}ck distribution, which depends on the
mean number of mutations, the relative fitness of normal cells compared to
mutants, and the division time distribution of mutant cells. Empirical
probability generating function techniques yield precise estimates both of the
mean number of mutations and the relative fitness of normal cells compared to
mutants. In the case where no information is available on the division time
distribution, it is shown that the estimation procedure using constant division
times yields more reliable results. Numerical results both on observed and
simulated data are reported
Measuring the Polarization of a Rapidly Precessing Deuteron Beam
This paper describes a time-marking system that enables a measurement of the
in-plane (horizontal) polarization of a 0.97-GeV/c deuteron beam circulating in
the Cooler Synchrotron (COSY) at the Forschungszentrum J\"ulich. The clock time
of each polarimeter event is used to unfold the 120-kHz spin precession and
assign events to bins according to the direction of the horizontal
polarization. After accumulation for one or more seconds, the down-up
scattering asymmetry can be calculated for each direction and matched to a
sinusoidal function whose magnitude is proportional to the horizontal
polarization. This requires prior knowledge of the spin tune or polarization
precession rate. An initial estimate is refined by re-sorting the events as the
spin tune is adjusted across a narrow range and searching for the maximum
polarization magnitude. The result is biased toward polarization values that
are too large, in part because of statistical fluctuations but also because
sinusoidal fits to even random data will produce sizeable magnitudes when the
phase is left free to vary. An analysis procedure is described that matches the
time dependence of the horizontal polarization to templates based on
emittance-driven polarization loss while correcting for the positive bias. This
information will be used to study ways to extend the horizontal polarization
lifetime by correcting spin tune spread using ring sextupole fields and thereby
to support the feasibility of searching for an intrinsic electric dipole moment
using polarized beams in a storage ring. This paper is a combined effort of the
Storage Ring EDM Collaboration and the JEDI Collaboration.Comment: 28 pages, 15 figures, prepared for Physical Review ST - Accelerators
and Beam
Prochlo: Strong Privacy for Analytics in the Crowd
The large-scale monitoring of computer users' software activities has become
commonplace, e.g., for application telemetry, error reporting, or demographic
profiling. This paper describes a principled systems architecture---Encode,
Shuffle, Analyze (ESA)---for performing such monitoring with high utility while
also protecting user privacy. The ESA design, and its Prochlo implementation,
are informed by our practical experiences with an existing, large deployment of
privacy-preserving software monitoring.
(cont.; see the paper
Large-Scale Spray Releases: Additional Aerosol Test Results
One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the relevant physical properties projected for actual WTP process streams
- …