    Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

    Get PDF
    Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, electronic, and unobtrusive measurement of BR in both healthcare and fitness monitoring. This paper presents a review of the literature on BR estimation from the ECG and PPG. First, the structure of BR algorithms and the mathematical techniques used at each stage are described. Second, the experimental methodologies that have been used to assess the performance of BR algorithms are reviewed, and a methodological framework for the assessment of BR algorithms is presented. Third, we outline the most pressing directions for future research, including the steps required to use BR algorithms in wearable sensors, remote video monitoring, and clinical practice

    Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study

    Get PDF
    Objective The presence of respiratory information within the pulse oximeter signal (PPG) is a well-documented phenomenon. However, extracting this information for the purpose of continuously monitoring respiratory rate requires: (1) the recognition of the multi-faceted manifestations of respiratory modulation components within the PPG and the complex interactions among them; (2) the implementation of appropriate advanced signal processing techniques to take full advantage of this information; and (3) the post-processing infrastructure to deliver a clinically useful reported respiratory rate to the end user. A holistic algorithmic approach to the problem is therefore required. We have developed the RROXI algorithm based on this principle and its performance on healthy subject trial data is described herein

    Extraction of respiratory signals from the electrocardiogram and photoplethysmogram: technical and physiological determinants.

    Get PDF
    OBJECTIVE: Breathing rate (BR) can be estimated by extracting respiratory signals from the electrocardiogram (ECG) or photoplethysmogram (PPG). The extracted respiratory signals may be influenced by several technical and physiological factors. In this study, our aim was to determine how technical and physiological factors influence the quality of respiratory signals. APPROACH: Using a variety of techniques 15 respiratory signals were extracted from the ECG, and 11 from PPG signals collected from 57 healthy subjects. The quality of each respiratory signal was assessed by calculating its correlation with a reference oral-nasal pressure respiratory signal using Pearson's correlation coefficient. MAIN RESULTS: Relevant results informing device design and clinical application were obtained. The results informing device design were: (i) seven out of 11 respiratory signals were of higher quality when extracted from finger PPG compared to ear PPG; (ii) laboratory equipment did not provide higher quality of respiratory signals than a clinical monitor; (iii) the ECG provided higher quality respiratory signals than the PPG; (iv) during downsampling of the ECG and PPG significant reductions in quality were first observed at sampling frequencies of  <250 Hz and  <16 Hz respectively. The results informing clinical application were: (i) frequency modulation-based respiratory signals were generally of lower quality in elderly subjects compared to young subjects; (ii) the qualities of 23 out of 26 respiratory signals were reduced at elevated BRs; (iii) there were no differences associated with gender. SIGNIFICANCE: Recommendations based on the results are provided regarding device designs for BR estimation, and clinical applications. The dataset and code used in this study are publicly available

    A Novel Respiratory Rate Estimation Algorithm from Photoplethysmogram Using Deep Learning Model

    Get PDF
    Respiratory rate (RR) is a critical vital sign that can provide valuable insights into various medical conditions, including pneumonia. Unfortunately, manual RR counting is often unreliable and discontinuous. Current RR estimation algorithms either lack the necessary accuracy or demand extensive window sizes. In response to these challenges, this study introduces a novel method for continuously estimating RR from photoplethysmogram (PPG) with a reduced window size and lower processing requirements. To evaluate and compare classical and deep learning algorithms, this study leverages the BIDMC and CapnoBase datasets, employing the Respiratory Rate Estimation (RRest) toolbox. The optimal classical techniques combination on the BIDMC datasets achieves a mean absolute error (MAE) of 1.9 breaths/min. Additionally, the developed neural network model utilises convolutional and long short-term memory layers to estimate RR effectively. The best-performing model, with a 50% train–test split and a window size of 7 s, achieves an MAE of 2 breaths/min. Furthermore, compared to other deep learning algorithms with window sizes of 16, 32, and 64 s, this study’s model demonstrates superior performance with a smaller window size. The study suggests that further research into more precise signal processing techniques may enhance RR estimation from PPG signals

    A 36 µW 1.1 mm2 reconfigurable analog front-end for cardiovascular and respiratory signals recording

    Get PDF
    © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other worksThis paper presents a 1.2 V 36 µW reconfigurable analog front-end (R-AFE) as a general-purpose low-cost IC for multiple-mode biomedical signals acquisition. The R-AFE efficiently reuses a reconfigurable preamplifier, a current generator (CG), and a mixed signal processing unit, having an area of 1.1 mm2 per R-AFE while supporting five acquisition modes to record different forms of cardiovascular and respiratory signals. The R-AFE can interface with voltage-, current-, impedance-, and light-sensors and hence can measure electrocardiography (ECG), bio-impedance (BioZ), photoplethysmogram (PPG), galvanic skin response (GSR), and general-purpose analog signals. Thanks to the chopper preamplifier and the low-noise CG utilizing dynamic element matching, the R-AFE mitigates 1/f noise from both the preamplifier and the CG for improved measurement sensitivity. The IC achieves competitive performance compared to the state-of-the-art dedicated readout ICs of ECG, BioZ, GSR, and PPG, but with approximately 1.4×-5.3× smaller chip area per channel.Peer ReviewedPostprint (author's final draft

    Finger and forehead PPG signal comparison for respiratory rate estimation

    Get PDF
    Objective: an evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Approach: finger-PPG, forehead-PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability (PWV), pulse amplitude variability (PAV) and the respiratory- induced intensity variability (RIIV). Respiratory rate was estimated from each one of the 4 PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Main results: results show a better performance in terms of successful estimation and relative error when: i) PPG signal is recorded in the finger; ii) the respiratory rate is less than 0.4 Hz; iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. Significance: these results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that finger is better than forehead to estimate respiratory rate

    Respiratory rate estimation from multi-channel signals using auto-regulated adaptive extended Kalman filter

    Get PDF
    Background: Respiration rate (RR) is a major cause for false alarms in intensive care units (ICU) and is primarily impaired by the artifact prone signals from skin-attached electrodes. Catheter-integrated esophageal electrodes are an alternative source for multi-channel physiological signals from multiple organs such as the heart and the diaphragm. Nonlinear estimation and sensor fusion are promising techniques for extracting the respiratory activity from such multi-component signals, however, pathologic breathing patterns with rapid RR changes typically observed in patient populations such as premature infants, pose significant challenges. Methods: We developed an auto-regulated adaptive extended Kalman filter (AA-EKF), which iteratively adapts the system model and the noise parameters based on the respiratory pattern. AA-EKF was tested on neonatal esophageal observations (NEO), and also on simulated multi-components signals created using waveforms in CapnoBase and ETNA databases. Results: AA-EKF derived RR (RRAA-EKF) from NEO had lower median (inter-quartile range) error of 0.1 (10.6) breaths per minute (bpm) compared to contemporary neonatal ICU monitors (RRNICU): −3.8 (15.7) bpm (p <0.001). RRAA-EKF error of −0.2 (3.2) bpm was achieved for ETNA wave forms and a bias (95% LOA) of 0.1 (−5.6, 5.9) in breath count. Mean absolute error (MAE) of RRAA-EKF with Capnobase waveforms, as median (inter-quartile range), at 0.3 (0.2) bpm was comparable to the literature reported values. Discussion: The auto-regulated approach allows RR estimation on a broad set of clinical data without requiring extensive patient specific adjustments. Causality and fast response times of EKF based algorithms makes the AA-EKF suitable for bedside monitoring in the ICU setting

    Laser-Induced Graphene for Heartbeat Monitoring with HeartPy Analysis

    Get PDF
    The HeartPy Python toolkit for analysis of noisy signals from heart rate measurements is an excellent tool to use in conjunction with novel wearable sensors. Nevertheless, most of the work to date has focused on applying the toolkit to data measured with commercially available sensors. We demonstrate the application of the HeartPy functions to data obtained with a novel graphene-based heartbeat sensor. We produce the sensor by laser-inducing graphene on a flexible polyimide substrate. Both graphene on the polyimide substrate and graphene transferred onto a PDMS substrate show piezoresistive behavior that can be utilized to measure human heartbeat by registering median cubital vein motion during blood pumping. We process electrical resistance data from the graphene sensor using HeartPy and demonstrate extraction of several heartbeat parameters, in agreement with measurements taken with independent reference sensors. We compare the quality of the heartbeat signal from graphene on different substrates, demonstrating that in all cases the device yields results consistent with reference sensors. Our work is a first demonstration of successful application of HeartPy to analysis of data from a sensor in development