5,300 research outputs found

    3D time series analysis of cell shape using Laplacian approaches

    Get PDF
    Background: Fundamental cellular processes such as cell movement, division or food uptake critically depend on cells being able to change shape. Fast acquisition of three-dimensional image time series has now become possible, but we lack efficient tools for analysing shape deformations in order to understand the real three-dimensional nature of shape changes. Results: We present a framework for 3D+time cell shape analysis. The main contribution is three-fold: First, we develop a fast, automatic random walker method for cell segmentation. Second, a novel topology fixing method is proposed to fix segmented binary volumes without spherical topology. Third, we show that algorithms used for each individual step of the analysis pipeline (cell segmentation, topology fixing, spherical parameterization, and shape representation) are closely related to the Laplacian operator. The framework is applied to the shape analysis of neutrophil cells. Conclusions: The method we propose for cell segmentation is faster than the traditional random walker method or the level set method, and performs better on 3D time-series of neutrophil cells, which are comparatively noisy as stacks have to be acquired fast enough to account for cell motion. Our method for topology fixing outperforms the tools provided by SPHARM-MAT and SPHARM-PDM in terms of their successful fixing rates. The different tasks in the presented pipeline for 3D+time shape analysis of cells can be solved using Laplacian approaches, opening the possibility of eventually combining individual steps in order to speed up computations

    Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates

    Get PDF
    The study of cerebral anatomy in developing neonates is of great importance for the understanding of brain development during the early period of life. This dissertation therefore focuses on three challenges in the modelling of cerebral anatomy in neonates during brain development. The methods that have been developed all use Magnetic Resonance Images (MRI) as source data. To facilitate study of vascular development in the neonatal period, a set of image analysis algorithms are developed to automatically extract and model cerebral vessel trees. The whole process consists of cerebral vessel tracking from automatically placed seed points, vessel tree generation, and vasculature registration and matching. These algorithms have been tested on clinical Time-of- Flight (TOF) MR angiographic datasets. To facilitate study of the neonatal cortex a complete cerebral cortex segmentation and reconstruction pipeline has been developed. Segmentation of the neonatal cortex is not effectively done by existing algorithms designed for the adult brain because the contrast between grey and white matter is reversed. This causes pixels containing tissue mixtures to be incorrectly labelled by conventional methods. The neonatal cortical segmentation method that has been developed is based on a novel expectation-maximization (EM) method with explicit correction for mislabelled partial volume voxels. Based on the resulting cortical segmentation, an implicit surface evolution technique is adopted for the reconstruction of the cortex in neonates. The performance of the method is investigated by performing a detailed landmark study. To facilitate study of cortical development, a cortical surface registration algorithm for aligning the cortical surface is developed. The method first inflates extracted cortical surfaces and then performs a non-rigid surface registration using free-form deformations (FFDs) to remove residual alignment. Validation experiments using data labelled by an expert observer demonstrate that the method can capture local changes and follow the growth of specific sulcus

    Medical Image Segmentation by Water Flow

    No full text
    We present a new image segmentation technique based on the paradigm of water flow and apply it to medical images. The force field analogy is used to implement the major water flow attributes like water pressure, surface tension and adhesion so that the model achieves topological adaptability and geometrical flexibility. A new snake-like force functional combining edge- and region-based forces is introduced to produce capability for both range and accuracy. The method has been assessed qualitatively and quantitatively, and shows decent detection performance as well as ability to handle noise

    Cube-Cut: Vertebral Body Segmentation in MRI-Data through Cubic-Shaped Divergences

    Full text link
    In this article, we present a graph-based method using a cubic template for volumetric segmentation of vertebrae in magnetic resonance imaging (MRI) acquisitions. The user can define the degree of deviation from a regular cube via a smoothness value Delta. The Cube-Cut algorithm generates a directed graph with two terminal nodes (s-t-network), where the nodes of the graph correspond to a cubic-shaped subset of the image's voxels. The weightings of the graph's terminal edges, which connect every node with a virtual source s or a virtual sink t, represent the affinity of a voxel to the vertebra (source) and to the background (sink). Furthermore, a set of infinite weighted and non-terminal edges implements the smoothness term. After graph construction, a minimal s-t-cut is calculated within polynomial computation time, which splits the nodes into two disjoint units. Subsequently, the segmentation result is determined out of the source-set. A quantitative evaluation of a C++ implementation of the algorithm resulted in an average Dice Similarity Coefficient (DSC) of 81.33% and a running time of less than a minute.Comment: 23 figures, 2 tables, 43 references, PLoS ONE 9(4): e9338

    Vascular Tree Structure: Fast Curvature Regularization and Validation

    Get PDF
    This work addresses the challenging problem of accurate vessel structure analysis in high resolution 3D biomedical images. Typical segmentation methods fail on recent micro-CT data sets resolving near-capillary vessels due to limitations of standard first-order regularization models. While regularization is needed to address noise and partial volume issues in the data, we argue that extraction of thin tubular structures requires higher-order curvature-based regularization. There are no standard segmentation methods regularizing surface curvature in 3D that could be applied to large 3D volumes. However, we observe that standard measures for vessels structure are more concerned with topology, bifurcation angles, and other parameters that can be directly addressed without segmentation. We propose a novel methodology reconstructing tree structure of the vessels using a new centerline curvature regularization technique. Our high-order regularization model is based on a recent curvature estimation method. We developed a Levenberg-Marquardt optimization scheme and an efficient GPU-based implementation of our algorithm. We also propose a validation mechanism based on synthetic vessel images. Our preliminary results on real ultra-resolution micro CT volumes are promising

    Skull Stripping of Neonatal Brain MRI: Using Prior Shape Information with Graph Cuts

    Get PDF
    In this paper, we propose a novel technique for skull stripping of infant (neonatal) brain magnetic resonance images using prior shape information within a graph cut framework. Skull stripping plays an important role in brain image analysis and is a major challenge for neonatal brain images. Popular methods like the brain surface extractor (BSE) and brain extraction tool (BET) do not produce satisfactory results for neonatal images due to poor tissue contrast, weak boundaries between brain and non-brain regions, and low spatial resolution. Inclusion of prior shape information helps in accurate identification of brain and non-brain tissues. Prior shape information is obtained from a set of labeled training images. The probability of a pixel belonging to the brain is obtained from the prior shape mask and included in the penalty term of the cost function. An extra smoothness term is based on gradient information that helps identify the weak boundaries between the brain and non-brain region. Experimental results on real neonatal brain images show that compared to BET, BSE, and other methods, our method achieves superior segmentation performance for neonatal brain images and comparable performance for adult brain image
    • …
    corecore