10,549 research outputs found

    Sub-pixel registration for low cost, low dosage, x-ray phase contrast imaging : a thesis presented in partial fulfilment of the requirements for the degree of Master of Engineering in Electronic and Computer Engineering at Massey University, Palmerston North, New Zealand

    Get PDF
    Figure 1.2 (=David et al., 2007 Fig 1a) was removed for copyright reasons. Figure 1.5 is re-used under a Creative Commons Attribution 4.0 International licence (CC by 4.0). Figures 4.3 & 4.4 are ©2007 IEEE and re-used with permission.X-ray phase contrast imaging is an imaging modality that measures the phase shift of the X-ray wavefronts as they travel through different materials. This gives a higher contrast between regions of similar X-ray attenuation, in a medical sense this corresponds to a higher contrast of soft tissues. A new area of research for X-ray phase contrast imaging is to use shadow-based intensity modulation to generate these images. This thesis explores a range of different registration techniques, and their suitability for phase contrast imaging using shadow based intensity modulation. Image registration is a key step in generating the phase contrast images as it is related to the x and y differential phase. These are then integrated to generate the phase contrast image. Therefor a high accuracy sub-pixel registration technique will provide high quality phase contrast images. The registration techniques explored are 1D curve 2-D surface fitting to a correlation map, phase registration, Newton-Raphson method, and optimal interpolation filtering. These registration techniques were tested with images that are noise free, as well as images corrupted by Poisson noise. The Newton-Raphson, and the optimal interpolation filters show the most promise due to low errors in the noise free environment. In the presence of noise, the Newton-Raphson method performs poorly, and hence requires a good denoising method, while the optimal interpolation filters do not get any improvement from any denoising techniques. Currently the Newton-Raphson based method are used widely in digital image correlation, however the optimal interpolation filtering has the benefit of not being limited by the choice of interpolation technique, and it removes the iterative process, and depending on the size of the optimal interpolation filter it performs better than, or only marginally worse than the Newton-Raphson method

    Motion compensated micro-CT reconstruction for in-situ analysis of dynamic processes

    Get PDF
    This work presents a framework to exploit the synergy between Digital Volume Correlation ( DVC) and iterative CT reconstruction to enhance the quality of high-resolution dynamic X-ray CT (4D-mu CT) and obtain quantitative results from the acquired dataset in the form of 3D strain maps which can be directly correlated to the material properties. Furthermore, we show that the developed framework is capable of strongly reducing motion artifacts even in a dataset containing a single 360 degrees rotation

    Combination of Imaging Infrared Spectroscopy and X-ray Computed Microtomography for the Investigation of Bio-and Physicochemical processes in Structured Soils

    Get PDF
    Soil is a heterogeneous mixture of various organic and inorganic parent materials. Major soil functions are driven by their quality, quantity and spatial arrangement, resulting in soil structure. Physical protection of organic matter (OM) in this soil structure is considered as a vital mechanism for stabilizing organic carbon turnover, an important soil function in times of climate change. Herein, we present a technique for the correlative analysis of 2D imaging visible light near-infrared spectroscopy and 3D X-ray computed microtomography (mCT) to investigate the interplay of biogeochemical properties and soil structure in undisturbed soil samples. Samples from the same substrate but different soil management and depth (no-tilled topsoil, tilled topsoil and subsoil) were compared in order to evaluate this method in a diversely structured soil. Imaging spectroscopy is generally used to qualitatively and quantitatively identify OM with high spatial resolution, whereas 3D X-ray mCT provides high resolution information on pore characteristics. The unique combination of these techniques revealed that, in undisturbed samples, OM can be found mainly at greater distances from macropores and close to biopores. However, alterations were observed because of disturbances by tillage. The correlative application of imaging infrared spectroscopic and X-ray mCT analysis provided new insights into the biochemical processes affected by soil structural changes

    Maskless imaging of dense samples using pixel super-resolution based multi-height lensfree on-chip microscopy.

    Get PDF
    Lensfree in-line holographic microscopy offers sub-micron resolution over a large field-of-view (e.g., ~24 mm2) with a cost-effective and compact design suitable for field use. However, it is limited to relatively low-density samples. To mitigate this limitation, we demonstrate an on-chip imaging approach based on pixel super-resolution and phase recovery, which iterates among multiple lensfree intensity measurements, each having a slightly different sample-to-sensor distance. By digitally aligning and registering these lensfree intensity measurements, phase and amplitude images of dense and connected specimens can be iteratively reconstructed over a large field-of-view of ~24 mm2 without the use of any spatial masks. We demonstrate the success of this multi-height in-line holographic approach by imaging dense Papanicolaou smears (i.e., Pap smears) and blood samples

    Overcoming the Challenges Associated with Image-based Mapping of Small Bodies in Preparation for the OSIRIS-REx Mission to (101955) Bennu

    Get PDF
    The OSIRIS-REx Asteroid Sample Return Mission is the third mission in NASA's New Frontiers Program and is the first U.S. mission to return samples from an asteroid to Earth. The most important decision ahead of the OSIRIS-REx team is the selection of a prime sample-site on the surface of asteroid (101955) Bennu. Mission success hinges on identifying a site that is safe and has regolith that can readily be ingested by the spacecraft's sampling mechanism. To inform this mission-critical decision, the surface of Bennu is mapped using the OSIRIS-REx Camera Suite and the images are used to develop several foundational data products. Acquiring the necessary inputs to these data products requires observational strategies that are defined specifically to overcome the challenges associated with mapping a small irregular body. We present these strategies in the context of assessing candidate sample-sites at Bennu according to a framework of decisions regarding the relative safety, sampleability, and scientific value across the asteroid's surface. To create data products that aid these assessments, we describe the best practices developed by the OSIRIS-REx team for image-based mapping of irregular small bodies. We emphasize the importance of using 3D shape models and the ability to work in body-fixed rectangular coordinates when dealing with planetary surfaces that cannot be uniquely addressed by body-fixed latitude and longitude.Comment: 31 pages, 10 figures, 2 table

    Pixelated detectors and improved efficiency for magnetic imaging in STEM differential phase contrast

    Get PDF
    The application of differential phase contrast imaging to the study of polycrystalline magnetic thin films and nanostructures has been hampered by the strong diffraction contrast resulting from the granular structure of the materials. In this paper we demonstrate how a pixelated detector has been used to detect the bright field disk in aberration corrected scanning transmission electron microscopy (STEM) and subsequent processing of the acquired data allows efficient enhancement of the magnetic contrast in the resulting images. Initial results from a charged coupled device (CCD) camera demonstrate the highly efficient nature of this improvement over previous methods. Further hardware development with the use of a direct radiation detector, the Medipix3, also shows the possibilities where the reduction in collection time is more than an order of magnitude compared to the CCD. We show that this allows subpixel measurement of the beam deflection due to the magnetic induction. While the detection and processing is data intensive we have demonstrated highly efficient DPC imaging whereby pixel by pixel interpretation of the induction variation is realised with great potential for nanomagnetic imaging

    Image processing for plastic surgery planning

    Get PDF
    This thesis presents some image processing tools for plastic surgery planning. In particular, it presents a novel method that combines local and global context in a probabilistic relaxation framework to identify cephalometric landmarks used in Maxillofacial plastic surgery. It also uses a method that utilises global and local symmetry to identify abnormalities in CT frontal images of the human body. The proposed methodologies are evaluated with the help of several clinical data supplied by collaborating plastic surgeons
    corecore