1,383 research outputs found

    A Fully Automatic Segmentation Method for Breast Ultrasound Images

    Get PDF
    Breast cancer is the second leading cause of death of women worldwide. Accurate lesion boundary detection is important for breast cancer diagnosis. Since many crucial features for discriminating benign and malignant lesions are based on the contour, shape, and texture of the lesion, an accurate segmentation method is essential for a successful diagnosis. Ultrasound is an effective screening tool and primarily useful for differentiating benign and malignant lesions. However, due to inherent speckle noise and low contrast of breast ultrasound imaging, automatic lesion segmentation is still a challenging task. This research focuses on developing a novel, effective, and fully automatic lesion segmentation method for breast ultrasound images. By incorporating empirical domain knowledge of breast structure, a region of interest is generated. Then, a novel enhancement algorithm (using a novel phase feature) and a newly developed neutrosophic clustering method are developed to detect the precise lesion boundary. Neutrosophy is a recently introduced branch of philosophy that deals with paradoxes, contradictions, antitheses, and antinomies. When neutrosophy is used to segment images with vague boundaries, its unique ability to deal with uncertainty is brought to bear. In this work, we apply neutrosophy to breast ultrasound image segmentation and propose a new clustering method named neutrosophic l-means. We compare the proposed method with traditional fuzzy c-means clustering and three other well-developed segmentation methods for breast ultrasound images, using the same database. Both accuracy and time complexity are analyzed. The proposed method achieves the best accuracy (TP rate is 94.36%, FP rate is 8.08%, and similarity rate is 87.39%) with a fairly rapid processing speed (about 20 seconds). Sensitivity analysis shows the robustness of the proposed method as well. Cases with multiple-lesions and severe shadowing effect (shadow areas having similar intensity values of the lesion and tightly connected with the lesion) are not included in this study

    Enhanced algorithms for lesion detection and recognition in ultrasound breast images

    Get PDF
    Mammography is the gold standard for breast cancer detection. However, it has very high false positive rates and is based on ionizing radiation. This has led to interest in using multi-modal approaches. One modality is diagnostic ultrasound, which is based on non-ionizing radiation and picks up many of the cancers that are generally missed by mammography. However, the presence of speckle noise in ultrasound images has a negative effect on image interpretation. Noise reduction, inconsistencies in capture and segmentation of lesions still remain challenging open research problems in ultrasound images. The target of the proposed research is to enhance the state-of-art computer vision algorithms used in ultrasound imaging and to investigate the role of computer processed images in human diagnostic performance. [Continues.

    Ultrasound IMT measurement on a multi-ethnic and multi-institutional database: Our review and experience using four fully automated and one semi-automated methods

    Get PDF
    Automated and high performance carotid intima-media thickness (IMT) measurement is gaining increasing importance in clinical practice to assess the cardiovascular risk of patients. In this paper, we compare four fully automated IMT measurement techniques (CALEX, CAMES, CARES and CAUDLES) and one semi-automated technique (FOAM). We present our experience using these algorithms, whose lumen-intima and media-adventitia border estimation use different methods that can be: (a) edge-based; (b) training-based; (c) feature-based; or (d) directional Edge-Flow based. Our database (DB) consisted of 665 images that represented a multi-ethnic group and was acquired using four OEM scanners. The performance evaluation protocol adopted error measures, reproducibility measures, and Figure of Merit (FoM). FOAM showed the best performance, with an IMT bias equal to 0.025 ± 0.225 mm, and a FoM equal to 96.6%. Among the four automated methods, CARES showed the best results with a bias of 0.032 ± 0.279 mm, and a FoM to 95.6%, which was statistically comparable to that of FOAM performance in terms of accuracy and reproducibility. This is the first time that completely automated and user-driven techniques have been compared on a multi-ethnic dataset, acquired using multiple original equipment manufacturer (OEM) machines with different gain settings, representing normal and pathologic case

    Fully automatic lesion boundary detection in ultrasound breast images

    Get PDF
    We propose a novel approach to fully automatic lesion boundary detection in ultrasound breast images. The novelty of the proposed work lies in the complete automation of the manual process of initial Region-of-Interest (ROI) labeling and in the procedure adopted for the subsequent lesion boundary detection. Histogram equalization is initially used to preprocess the images followed by hybrid filtering and multifractal analysis stages. Subsequently, a single valued thresholding segmentation stage and a rule-based approach is used for the identification of the lesion ROI and the point of interest that is used as the seed-point. Next, starting from this point an Isotropic Gaussian function is applied on the inverted, original ultrasound image. The lesion area is then separated from the background by a thresholding segmentation stage and the initial boundary is detected via edge detection. Finally to further improve and refine the initial boundary, we make use of a state-of-the-art active contour method (i.e. gradient vector flow (GVF) snake model). We provide results that include judgments from expert radiologists on 360 ultrasound images proving that the final boundary detected by the proposed method is highly accurate. We compare the proposed method with two existing stateof- the-art methods, namely the radial gradient index filtering (RGI) technique of Drukker et. al. and the local mean technique proposed by Yap et. al., in proving the proposed method’s robustness and accuracy

    Breast Ultrasound Past, Present, and Future

    Get PDF
    This chapter will review the utilization of breast ultrasound for screening and diagnostic purposes. Currently, ultrasound is primarily used to investigate palpable lesions in women less than 30 years old, to provide further characterization of abnormal mammographic findings, and to guide invasive breast interventions. Innovations in ultrasound technology have improved the detection and diagnosis of breast cancer. Computer-aided detection (CAD), elastography, quantitative breast ultrasound technology, and ultrasound contrast agents (microbubbles) were developed to improve diagnostic accuracy. These advancements have the potential to impact overall survival by detecting cancers that are smaller and less aggressive

    Hybrid Speckle Noise Reduction Method for Abdominal Circumference Segmentation of Fetal Ultrasound Images

    Get PDF
    Fetal biometric size such as abdominal circumference (AC) is used to predict fetal weight or gestational age in ultrasound images. The automatic biometric measurement can improve efficiency in the ultrasonography examination workflow. The unclear boundaries of the abdomen image and the speckle noise presence are the challenges for the automated AC measurement techniques. The main problem to improve the accuracy of the automatic AC segmentation is how to remove noise while retaining the boundary features of objects. In this paper, we proposed a hybrid ultrasound image denoising framework which was a combination of spatial-based filtering method and multiresolution based method.  In this technique, an ultrasound image was decomposed into subbands using wavelet transform. A thresholding technique and the anisotropic diffusion method were applied to the detail subbands, at the same time the bilateral filtering modified the approximation subband. The proposed denoising approach had the best performance in the edge preservation level and could improve the accuracy of the abdominal circumference segmentation
    • …
    corecore