76 research outputs found

    Robust Depth Linear Error Decomposition with Double Total Variation and Nuclear Norm for Dynamic MRI Reconstruction

    Full text link
    Compressed Sensing (CS) significantly speeds up Magnetic Resonance Image (MRI) processing and achieves accurate MRI reconstruction from under-sampled k-space data. According to the current research, there are still several problems with dynamic MRI k-space reconstruction based on CS. 1) There are differences between the Fourier domain and the Image domain, and the differences between MRI processing of different domains need to be considered. 2) As three-dimensional data, dynamic MRI has its spatial-temporal characteristics, which need to calculate the difference and consistency of surface textures while preserving structural integrity and uniqueness. 3) Dynamic MRI reconstruction is time-consuming and computationally resource-dependent. In this paper, we propose a novel robust low-rank dynamic MRI reconstruction optimization model via highly under-sampled and Discrete Fourier Transform (DFT) called the Robust Depth Linear Error Decomposition Model (RDLEDM). Our method mainly includes linear decomposition, double Total Variation (TV), and double Nuclear Norm (NN) regularizations. By adding linear image domain error analysis, the noise is reduced after under-sampled and DFT processing, and the anti-interference ability of the algorithm is enhanced. Double TV and NN regularizations can utilize both spatial-temporal characteristics and explore the complementary relationship between different dimensions in dynamic MRI sequences. In addition, Due to the non-smoothness and non-convexity of TV and NN terms, it is difficult to optimize the unified objective model. To address this issue, we utilize a fast algorithm by solving a primal-dual form of the original problem. Compared with five state-of-the-art methods, extensive experiments on dynamic MRI data demonstrate the superior performance of the proposed method in terms of both reconstruction accuracy and time complexity

    Proceedings of the second "international Traveling Workshop on Interactions between Sparse models and Technology" (iTWIST'14)

    Get PDF
    The implicit objective of the biennial "international - Traveling Workshop on Interactions between Sparse models and Technology" (iTWIST) is to foster collaboration between international scientific teams by disseminating ideas through both specific oral/poster presentations and free discussions. For its second edition, the iTWIST workshop took place in the medieval and picturesque town of Namur in Belgium, from Wednesday August 27th till Friday August 29th, 2014. The workshop was conveniently located in "The Arsenal" building within walking distance of both hotels and town center. iTWIST'14 has gathered about 70 international participants and has featured 9 invited talks, 10 oral presentations, and 14 posters on the following themes, all related to the theory, application and generalization of the "sparsity paradigm": Sparsity-driven data sensing and processing; Union of low dimensional subspaces; Beyond linear and convex inverse problem; Matrix/manifold/graph sensing/processing; Blind inverse problems and dictionary learning; Sparsity and computational neuroscience; Information theory, geometry and randomness; Complexity/accuracy tradeoffs in numerical methods; Sparsity? What's next?; Sparse machine learning and inference.Comment: 69 pages, 24 extended abstracts, iTWIST'14 website: http://sites.google.com/site/itwist1

    Design of Microwave-based Brain Tumor Detection Framework with the Development of Sparse and Low-Rank Compressive Sensing Image Reconstruction

    Get PDF
    Cancer is one of the leading causes of death, and the brain is one of the body’s cancer-prone organs.  The early detection of brain tumors can reduce cancer risk, which is practically assisted and conducted using scanners such as computed tomography (CT) and magnetic resonance imaging (MRI). However, those modalities are high-cost and large-sized, and they have a side effect risk to health. Alternatively, microwave imaging offers a novel cancer scanning method for early detection with low cost, small size and low health risk. Consequently, this research designs and creates a framework with a novel microwave image reconstruction algorithm inside. The framework is a component of the controller and image reconstructor for a portable microwave-based brain tumor detector that is open source and multi-platform. For the novel algorithm, this research proposes a CS-based imaging algorithm by exploiting the data‘s sparse and low-rank properties. The experiment shows that the proposed algorithm can give better qualitative and quantitative reconstruction results compared to a full-sampling-based as well as CS-based algorithm

    Modal decomposition from partial measurements

    Get PDF
    International audienceA data set over space and time is assumed to have a low rank representation in separated spatial and temporal modes. The problem of evaluating these modes from a temporal series of partial measurements is considered. Each elementary instantaneous measurement captures only a window (in space) of the observed data set, but the window position varies in time so as to cover the entire region of interest and would allow for a complete measurement would the scene be static. A novel procedure, alternative to the Gappy Proper Orthogonal Decomposition (GPOD) methodology, is introduced. It is a xed point iterative procedure where modes are evaluated sequentially. Tested upon very sparse acquisition (1% of measurements being available) and very noisy synthetic data sets (10% noise), the proposed algorithm is shown to outperform two variants of the GPOD algorithm, with much faster convergence, and better reconstruction of the entire data set

    Sparse and low-rank techniques for the efficient restoration of images

    Get PDF
    Image reconstruction is a key problem in numerous applications of computer vision and medical imaging. By removing noise and artifacts from corrupted images, or by enhancing the quality of low-resolution images, reconstruction methods are essential to provide high-quality images for these applications. Over the years, extensive research efforts have been invested toward the development of accurate and efficient approaches for this problem. Recently, considerable improvements have been achieved by exploiting the principles of sparse representation and nonlocal self-similarity. However, techniques based on these principles often suffer from important limitations that impede their use in high-quality and large-scale applications. Thus, sparse representation approaches consider local patches during reconstruction, but ignore the global structure of the image. Likewise, because they average over groups of similar patches, nonlocal self-similarity methods tend to over-smooth images. Such methods can also be computationally expensive, requiring a hour or more to reconstruct a single image. Furthermore, existing reconstruction approaches consider either local patch-based regularization or global structure regularization, due to the complexity of combining both regularization strategies in a single model. Yet, such combined model could improve upon existing techniques by removing noise or reconstruction artifacts, while preserving both local details and global structure in the image. Similarly, current approaches rarely consider external information during the reconstruction process. When the structure to reconstruct is known, external information like statistical atlases or geometrical priors could also improve performance by guiding the reconstruction. This thesis addresses limitations of the prior art through three distinct contributions. The first contribution investigates the histogram of image gradients as a powerful prior for image reconstruction. Due to the trade-off between noise removal and smoothing, image reconstruction techniques based on global or local regularization often over-smooth the image, leading to the loss of edges and textures. To alleviate this problem, we propose a novel prior for preserving the distribution of image gradients modeled as a histogram. This prior is combined with low-rank patch regularization in a single efficient model, which is then shown to improve reconstruction accuracy for the problems of denoising and deblurring. The second contribution explores the joint modeling of local and global structure regularization for image restoration. Toward this goal, groups of similar patches are reconstructed simultaneously using an adaptive regularization technique based on the weighted nuclear norm. An innovative strategy, which decomposes the image into a smooth component and a sparse residual, is proposed to preserve global image structure. This strategy is shown to better exploit the property of structure sparsity than standard techniques like total variation. The proposed model is evaluated on the problems of completion and super-resolution, outperforming state-of-the-art approaches for these tasks. Lastly, the third contribution of this thesis proposes an atlas-based prior for the efficient reconstruction of MR data. Although popular, image priors based on total variation and nonlocal patch similarity often over-smooth edges and textures in the image due to the uniform regularization of gradients. Unlike natural images, the spatial characteristics of medical images are often restricted by the target anatomical structure and imaging modality. Based on this principle, we propose a novel MRI reconstruction method that leverages external information in the form of an probabilistic atlas. This atlas controls the level of gradient regularization at each image location, via a weighted total-variation prior. The proposed method also exploits the redundancy of nonlocal similar patches through a sparse representation model. Experiments on a large scale dataset of T1-weighted images show this method to be highly competitive with the state-of-the-art

    Combinatorial optimisation for arterial image segmentation.

    Get PDF
    Cardiovascular disease is one of the leading causes of the mortality in the western world. Many imaging modalities have been used to diagnose cardiovascular diseases. However, each has different forms of noise and artifacts that make the medical image analysis field important and challenging. This thesis is concerned with developing fully automatic segmentation methods for cross-sectional coronary arterial imaging in particular, intra-vascular ultrasound and optical coherence tomography, by incorporating prior and tracking information without any user intervention, to effectively overcome various image artifacts and occlusions. Combinatorial optimisation methods are proposed to solve the segmentation problem in polynomial time. A node-weighted directed graph is constructed so that the vessel border delineation is considered as computing a minimum closed set. A set of complementary edge and texture features is extracted. Single and double interface segmentation methods are introduced. Novel optimisation of the boundary energy function is proposed based on a supervised classification method. Shape prior model is incorporated into the segmentation framework based on global and local information through the energy function design and graph construction. A combination of cross-sectional segmentation and longitudinal tracking is proposed using the Kalman filter and the hidden Markov model. The border is parameterised using the radial basis functions. The Kalman filter is used to adapt the inter-frame constraints between every two consecutive frames to obtain coherent temporal segmentation. An HMM-based border tracking method is also proposed in which the emission probability is derived from both the classification-based cost function and the shape prior model. The optimal sequence of the hidden states is computed using the Viterbi algorithm. Both qualitative and quantitative results on thousands of images show superior performance of the proposed methods compared to a number of state-of-the-art segmentation methods

    Efficient Model-Based Reconstruction for Dynamic MRI

    Full text link
    Dynamic magnetic resonance imaging (MRI) has important clinical and neuro- science applications (e.g., cardiac disease diagnosis, neurological behavior studies). It captures an object in motion by acquiring data across time, then reconstructing a sequence of images from them. This dissertation considers efficient dynamic MRI reconstruction using handcrafted models, to achieve fast imaging with high spatial and temporal resolution. Our modeling framework considers data acquisition process, image properties, and artifact correction. The reconstruction model expressed as a large-scale inverse problem requires optimization algorithms to solve, and we consider efficient implementations that make use of underlying problem structures. In the context of dynamic MRI reconstruction, we investigate efficient updates in two frameworks of algorithms for solving a nonsmooth composite convex optimization problem for the low-rank plus sparse (L+S) model. In the proximal gradient framework, current algorithms for the L+S model involve the classical iterative soft thresholding algorithm (ISTA); we consider two accelerated alternatives, one based on the fast iterative shrinkage-thresholding algorithm (FISTA), and the other with the recent proximal optimized gradient method (POGM). In the augmented Lagrangian (AL) framework, we propose an efficient variable splitting scheme based on the form of the data acquisition operator, leading to simpler computation than the conjugate gradient (CG) approach required by existing AL methods. Numerical results suggest faster convergence of our efficient implementations in both frameworks, with POGM providing the fastest convergence overall and the practical benefit of being free of algorithm tuning parameters. In the context of magnetic field inhomogeneity correction, we present an efficient algorithm for a regularized field inhomogeneity estimation problem. Most existing minimization techniques are computationally or memory intensive for 3D datasets, and are designed for single-coil MRI. We consider 3D MRI with optional consideration of coil sensitivity and a generalized expression that addresses both multi-echo field map estimation and water-fat imaging. Our efficient algorithm uses a preconditioned nonlinear conjugate gradient method based on an incomplete Cholesky factorization of the Hessian of the cost function, along with a monotonic line search. Numerical experiments show the computational advantage of the proposed algorithm over state- of-the-art methods with similar memory requirements. In the context of task-based functional MRI (fMRI) reconstruction, we introduce a space-time model that represents an fMRI timeseries as a sum of task-correlated signal and non-task background. Our model consists of a spatiotemporal decomposition based on assumptions of the activation waveform shape, with spatial and temporal smoothness regularization on the magnitude and phase of the timeseries. Compared with two contemporary task fMRI decomposition models, our proposed model yields better timeseries and activation maps on simulated and human subject fMRI datasets with multiple tasks. The above examples are part of a larger framework for model-based dynamic MRI reconstruction. This dissertation concludes by presenting a general framework with flexibility on model assumptions and artifact compensation options (e.g., field inhomogeneity, head motion), and proposing future work ideas on both the framework and its connection to data acquisition.PHDApplied and Interdisciplinary MathematicsUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/168081/1/yilinlin_1.pd

    3-D lung deformation and function from respiratory-gated 4-D x-ray CT images : application to radiation treatment planning.

    Get PDF
    Many lung diseases or injuries can cause biomechanical or material property changes that can alter lung function. While the mechanical changes associated with the change of the material properties originate at a regional level, they remain largely asymptomatic and are invisible to global measures of lung function until they have advanced significantly and have aggregated. In the realm of external beam radiation therapy of patients suffering from lung cancer, determination of patterns of pre- and post-treatment motion, and measures of regional and global lung elasticity and function are clinically relevant. In this dissertation, we demonstrate that 4-D CT derived ventilation images, including mechanical strain, provide an accurate and physiologically relevant assessment of regional pulmonary function which may be incorporated into the treatment planning process. Our contributions are as follows: (i) A new volumetric deformable image registration technique based on 3-D optical flow (MOFID) has been designed and implemented which permits the possibility of enforcing physical constraints on the numerical solutions for computing motion field from respiratory-gated 4-D CT thoracic images. The proposed optical flow framework is an accurate motion model for the thoracic CT registration problem. (ii) A large displacement landmark-base elastic registration method has been devised for thoracic CT volumetric image sets containing large deformations or changes, as encountered for example in registration of pre-treatment and post-treatment images or multi-modality registration. (iii) Based on deformation maps from MOFIO, a novel framework for regional quantification of mechanical strain as an index of lung functionality has been formulated for measurement of regional pulmonary function. (iv) In a cohort consisting of seven patients with non-small cell lung cancer, validation of physiologic accuracy of the 4-0 CT derived quantitative images including Jacobian metric of ventilation, Vjac, and principal strains, (V?1, V?2, V?3, has been performed through correlation of the derived measures with SPECT ventilation and perfusion scans. The statistical correlations with SPECT have shown that the maximum principal strain pulmonary function map derived from MOFIO, outperforms all previously established ventilation metrics from 40-CT. It is hypothesized that use of CT -derived ventilation images in the treatment planning process will help predict and prevent pulmonary toxicity due to radiation treatment. It is also hypothesized that measures of regional and global lung elasticity and function obtained during the course of treatment may be used to adapt radiation treatment. Having objective methods with which to assess pre-treatment global and regional lung function and biomechanical properties, the radiation treatment dose can potentially be escalated to improve tumor response and local control
    • …
    corecore