7 research outputs found
Single Shot High Dynamic Range Imaging Using Piecewise Linear Estimators
International audienceBuilding high dynamic range (HDR) images by combining photographs captured with different exposure times present several drawbacks, such as the need for global alignment and motion estimation in order to avoid ghosting artifacts. The concept of spatially varying pixel exposures (SVE) proposed by Nayar et al. enables to capture in only one shot a very large range of exposures while avoiding these limitations. In this paper, we propose a novel approach to generate HDR images from a single shot acquired with spatially varying pixel exposures. The proposed method makes use of the assumption stating that the distribution of patches in an image is well represented by a Gaussian Mixture Model. Drawing on a precise modeling of the camera acquisition noise, we extend the piecewise linear estimation strategy developed by Yu et al. for image restoration. The proposed method permits to reconstruct an irradiance image by simultaneously estimating saturated and under-exposed pixels and denoising existing ones, showing significant improvements over existing approaches
Convolutional sparse coding for high dynamic range imaging
Current HDR acquisition techniques are based on either (i) fusing multibracketed, low dynamic range (LDR) images, (ii) modifying existing hardware and capturing different exposures simultaneously with multiple sensors, or (iii) reconstructing a single image with spatially-varying pixel exposures. In this paper, we propose a novel algorithm to recover high-quality HDRI images from a single, coded exposure. The proposed reconstruction method builds on recently-introduced ideas of convolutional sparse coding (CSC); this paper demonstrates how to make CSC practical for HDR imaging. We demonstrate that the proposed algorithm achieves higher-quality reconstructions than alternative methods, we evaluate optical coding schemes, analyze algorithmic parameters, and build a prototype coded HDR camera that demonstrates the utility of convolutional sparse HDRI coding with a custom hardware platform
Non-parametric Methods for Automatic Exposure Control, Radiometric Calibration and Dynamic Range Compression
Imaging systems are essential to a wide range of modern day
applications. With the continuous advancement in imaging systems,
there is an on-going need to adapt and improve the imaging
pipeline running inside the imaging systems.
In this thesis, methods are presented to improve the imaging
pipeline of digital cameras. Here we present three methods to
improve important phases of the imaging process, which are (i)
``Automatic exposure adjustment'' (ii) ``Radiometric
calibration'' (iii) ''High dynamic range compression''. These
contributions touch the initial, intermediate and final stages of
imaging pipeline of digital cameras.
For exposure control, we propose two methods. The first makes use
of CCD-based equations to formulate the exposure control problem.
To estimate the exposure time, an initial image was acquired for
each wavelength channel to which contrast adjustment techniques
were applied. This helps to recover a reference cumulative
distribution function of image brightness at each channel. The
second method proposed for automatic exposure control is an
iterative method applicable for a broad range of imaging systems.
It uses spectral sensitivity functions such as the photopic
response functions for the generation of a spectral power image
of the captured scene. A target image is then generated using the
spectral power image by applying histogram equalization. The
exposure time is hence calculated iteratively by minimizing the
squared difference between target and the current spectral power
image. Here we further analyze the method by performing its
stability and controllability analysis using a state space
representation used in control theory. The applicability of the
proposed method for exposure time calculation was shown on real
world scenes using cameras with varying architectures.
Radiometric calibration is the estimate of the non-linear mapping
of the input radiance map to the output brightness values. The
radiometric mapping is represented by the camera response
function with which the radiance map of the scene is estimated.
Our radiometric calibration method employs an L1 cost function by
taking advantage of Weisfeld optimization scheme. The proposed
calibration works with multiple input images of the scene with
varying exposure. It can also perform calibration using a single
input with few constraints. The proposed method outperforms,
quantitatively and qualitatively, various alternative methods
found in the literature of radiometric calibration.
Finally, to realistically represent the estimated radiance maps
on low dynamic range display (LDR) devices, we propose a method
for dynamic range compression. Radiance maps generally have
higher dynamic range (HDR) as compared to the widely used display
devices. Thus, for display purposes, dynamic range compression is
required on HDR images. Our proposed method generates few LDR
images from the HDR radiance map by clipping its values at
different exposures. Using contrast information of each LDR
image generated, the method uses an energy minimization approach
to estimate the probability map of each LDR image. These
probability maps are then used as label set to form final
compressed dynamic range image for the display device. The
results of our method were compared qualitatively and
quantitatively with those produced by widely cited and
professionally used methods