4,309 research outputs found

    Magnetocardiography in unshielded environment based on optical magnetometry and adaptive noise cancellation

    Get PDF
    This thesis proposes and demonstrates the concept of a magnetocardiographic system employing an array of optically-pumped quantum magnetometers and an adaptive noise cancellation for heart magnetic field measurement within a magnetically-unshielded environment. Optically-pumped quantum magnetometers are based on the use of the atomic-spin-dependent optical properties of an atomic medium. An Mxconfiguration- based optically-pumped quantum magnetometer employing two sensing cells containing caesium vapour is theoretically described and experimentally developed, and the dependence of its sensitivity and frequency bandwidth upon the light power and the alkali vapour temperature is experimentally demonstrated. Furthermore, the capability of the developed magnetometer of measuring very weak magnetic fields is experimentally demonstrated in a magnetically-unshielded environment. The adaptive noise canceller is based on standard Least-Mean-Squares (LMS) algorithms and on two heuristic optimization techniques, namely, Genetic Algorithms (GA) and Particle Swarm Optimization (PSO). The use of these algorithms is investigated for suppressing the power line generated 50Hz interference and recovering of the weak magnetic heart signals from a much higher electromagnetic environmental noise. Experimental results show that all the algorithms can extract a weak heart signal from a much-stronger magnetic noise, detect the P, QRS, and T heart features and highly suppress the common power line noise component at 50 Hz. Moreover, adaptive noise cancellation based on heuristic algorithms is shown to be more efficient than adaptive noise canceller based on standard or normalised LMS algorithm in heart features detection

    Chip-scale atomic magnetometer based on free-induction-decay

    Get PDF
    This thesis describes the implementation of an optically pumped caesium magnetometer containing a 1:5mm thick microfabricated vapour cell with nitrogen buffer gas, operating in a free-induction-decay configuration. This allows us to monitor the free Larmor precession of the spin coherent Cs atoms by separating the pump and probe phases in the time domain. A single light pulse can sufficiently polarise the atomic sample;however, synchronous modulation of the light field actively drives the precession and maximises the induced spin coherence. Both amplitude- and frequency-modulation have been adopted producing noise floors of 3.4 pT / √Hz and 15.6 pT/√Hz, respectively,within a Nyquist limited bandwidth of 500 Hz in a bias field comparable to the Earth's (~50 μT). We investigate the magnetometers capability in reproducing time-varying magnetic signals under these conditions, including the reconstruction of a 100 pT perturbation using signal averaging.Additionally, we discuss a novel detection mode based on free-induction-decay that observes the spin precession dynamics in-the-dark using Ramsey-like pulses. This aids in suppressing the systematic effects originating from the light-atom interaction during readout, thus vastly improving the accuracy of the magnetometer whilst maintaining a sensitivity that is competitive with previous implementations. This detection technique was implemented further to measure the spin relaxation properties intrinsic to the sensor head, useful in determining the optimal buffer pressure that extends the spin lifetime and improves the sensor's sensitivity performance.This thesis describes the implementation of an optically pumped caesium magnetometer containing a 1:5mm thick microfabricated vapour cell with nitrogen buffer gas, operating in a free-induction-decay configuration. This allows us to monitor the free Larmor precession of the spin coherent Cs atoms by separating the pump and probe phases in the time domain. A single light pulse can sufficiently polarise the atomic sample;however, synchronous modulation of the light field actively drives the precession and maximises the induced spin coherence. Both amplitude- and frequency-modulation have been adopted producing noise floors of 3.4 pT / √Hz and 15.6 pT/√Hz, respectively,within a Nyquist limited bandwidth of 500 Hz in a bias field comparable to the Earth's (~50 μT). We investigate the magnetometers capability in reproducing time-varying magnetic signals under these conditions, including the reconstruction of a 100 pT perturbation using signal averaging.Additionally, we discuss a novel detection mode based on free-induction-decay that observes the spin precession dynamics in-the-dark using Ramsey-like pulses. This aids in suppressing the systematic effects originating from the light-atom interaction during readout, thus vastly improving the accuracy of the magnetometer whilst maintaining a sensitivity that is competitive with previous implementations. This detection technique was implemented further to measure the spin relaxation properties intrinsic to the sensor head, useful in determining the optimal buffer pressure that extends the spin lifetime and improves the sensor's sensitivity performance

    Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters

    Full text link
    The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of 163^{163}Ho with a statistical sensitivity on the neutrino mass as low as ∼1\sim 1 eV/c2^2. In order to acquire the large needed statistics, by keeping the pile-up contribution as low as possible, 1024 transition edge sensors (TESs) with high energy and time resolutions will be employed. Microcalorimeter and bolometer arrays based on transition edge sensor with thousands of pixels are under development for several space-based and ground-based applications, including astrophysics, nuclear and particle physics, and materials science. The common necessary challenge is to develop pratical multiplexing techniques in order to simplify the cryogenics and readout systems. Despite the various multiplexing variants which are being developed have been successful, new approaches are needed to enable scaling to larger pixel counts and faster sensors, as requested for HOLMES, reducing also the cost and complexity of readout. A very novel technique that meets all of these requirements is based on superconducting microwave resonators coupled to radio-frequency Superconducting Quantum Interference Devices, in which the the changes in the TES input current is tranduced to a change in phase of a microwave signal. In this work we introduce the basics of this technique, the design and development of the first two-channel read out system and its performances with the first TES detectors specifically designed for HOLMES. In the last part we explain how to extend this approach scaling to 1024 pixels.Comment: accepted on JINS

    A programmable two-qubit quantum processor in silicon

    Full text link
    With qubit measurement and control fidelities above the threshold of fault-tolerance, much attention is moving towards the daunting task of scaling up the number of physical qubits to the large numbers needed for fault tolerant quantum computing. Here, quantum dot based spin qubits may offer significant advantages due to their potential for high densities, all-electrical operation, and integration onto an industrial platform. In this system, the initialisation, readout, single- and two-qubit gates have been demonstrated in various qubit representations. However, as seen with other small scale quantum computer demonstrations, combining these elements leads to new challenges involving qubit crosstalk, state leakage, calibration, and control hardware which provide invaluable insight towards scaling up. Here we address these challenges and demonstrate a programmable two-qubit quantum processor in silicon by performing both the Deutsch-Josza and the Grover search algorithms. In addition, we characterise the entanglement in our processor through quantum state tomography of Bell states measuring state fidelities between 85-89% and concurrences between 73-80%. These results pave the way for larger scale quantum computers using spins confined to quantum dots

    New Experimental Limit on the Electric Dipole Moment of the Electron in a Paramagnetic Insulator

    Full text link
    We report results of an experimental search for the intrinsic Electric Dipole Moment (EDM) of the electron using a solid-state technique. The experiment employs a paramagnetic, insulating gadolinium gallium garnet (GGG) that has a large magnetic response at low temperatures. The presence of the eEDM would lead to a small but non-zero magnetization as the GGG sample is subject to a strong electric field. We search for the resulting Stark-induced magnetization with a sensitive magnetometer. Recent progress on the suppression of several sources of background allows the experiment to run free of spurious signals at the level of the statistical uncertainties. We report our first limit on the eEDM of (−5.57±7.98±0.12)×(-5.57 \pm 7.98 \pm 0.12)\times10−25^{-25}e⋅\cdotcm with 5 days of data averaging.Comment: 9 pages, 9 figures, Revtex 4.

    Electromagnetic Induction Imaging with Atomic Magnetometers

    Get PDF
    Electromagnetic induction imaging (EMI) is a technique for non-invasively mapping the passive electromagnetic properties of materials. It involves the active probing of samples with a radio-frequency magnetic field and recording the details of the magnetic field produced by the induced eddy current response. The performance of an EMI system is ultimately determined by the choice of magnetic field sensor used in the measurement. The sensor’s sensitivity, range of operation frequency, and sensing volume are all crucial characteristics when considering the imaging platform’s capabilities. Atomic magnetometers (AMs) – based on the coherent precession of a polarised alkali atomic vapour – currently rate amongst the most sensitive devices for magnetic field measurements. Radio-frequency atomic magnetometers (RF-AMs) are ultra-sensitive detectors of oscillating magnetic fields across a broad range of frequencies. As such, they are ideally suited to EMI applications. This work presents the development of EMI systems based on RF-AMs. The imaging performance and a wide range of applications are experimentally demonstrated. The continuous development of a single-channel rubidium RF-AM is described. The final device operates in unshielded environments and near room temperature with a measured sensitivity of 55 fT/√Hz, a photon-shot noise limit of 10 fT/√Hz, and a linewidth of 36 Hz. Tunability of the device is proven by consistent, narrow-linewidth operation across the kHz – MHz band – operating in magnetic fields significantly greater than previous AM designs. The sensor was developed with a small effective sensor volume, which increases the spatial resolution of the imaging. High-resolution EMI is performed across a broad range of materials. This spans the first EMI images with an RF-AM at 6x107 S/m to low-conductivity, non-metallic samples at 500 S/m. Typically, sample volumes are of a few cm3 and with an imaging resolution around 1 mm. These numbers make EMI with AMs (EMI-AM) suitable for numerous applications. Techniques – including multi-frequency image analysis – are employed to discriminate sample properties. Further work developed novel image reconstruction approaches – based on machine learning – to maximise the amount of information that can be extracted from EMI images. Finally, the potential of biomedical imaging is discussed and its feasibility verified by simulating the application of EMI-AM to imaging the conductivity of the heart

    Hyperfine-phonon spin relaxation in a single-electron GaAs quantum dot

    Get PDF
    Understanding and control of the spin relaxation time T-1 is among the key challenges for spinbased qubits. A larger T-1 is generally favored, setting the fundamental upper limit to the qubit coherence and spin readout fidelity. In GaAs quantum dots at low temperatures and high inplane magnetic fields B, the spin relaxation relies on phonon emission and spin-orbit coupling. The characteristic dependence T-1 alpha B-5 and pronounced B-field anisotropy were already confirmed experimentally. However, it has also been predicted 15 years ago that at low enough fields, the spin-orbit interaction is replaced by the coupling to the nuclear spins, where the relaxation becomes isotropic, and the scaling changes to T-1 alpha B-3. Here, we establish these predictions experimentally, by measuring T-1 over an unprecedented range of magnetic fields-made possible by lower temperature-and report a maximum T-1 = 57 +/- 15 s at the lowest fields, setting a record electron spin lifetime in a nanostructure

    The Future of Neutrino Mass Measurements: Terrestrial, Astrophysical, and Cosmological Measurements in the Next Decade. Highlights of the NuMass 2013 Workshop. Milano, Italy, February 4 - 7, 2013

    Full text link
    The third Workshop of the NuMass series ("The Future of Neutrino Mass Measurements: Terrestrial, Astrophysical, and Cosmological Measurements in the Next Decade: NuMass 2013") was held at Dipartimento di Fisica "G. Occhialini, University of Milano-Bicocca in Milano, Italy, on 4-7 February 2013. The goal of this international workshop was to review the status and future of direct and indirect neutrino mass measurements in the laboratory as well as from astrophysical and cosmological observations. This paper collects most of the contributions presented during the Workshop
    • …
    corecore