4 research outputs found

    UDE-based controller equipped with a multiple-time-delayed filter to improve the voltage quality of inverters

    Get PDF
    In this paper, a two-degrees-of-freedom control algorithm based on uncertainty and disturbance estimator (UDE), aimed to minimize the total harmonic distortion of inverter output voltage is proposed, possessing enhanced robustness to base frequency variations. A multiple-time-delay action is combined with a commonly utilized low-pass UDE filter to increase the range of output impedance magnitude minimization around odd multiples of base frequency for enhanced rejection of typical single-phase nonlinear loads harmonics. Marginal robustness improvement achieved by increasing the number of time delays is quantified analytically and revealed to be independent of delay order. The performance of the proposed control approach and its superiority over two recently proposed methods is validated successfully by experimental results

    Composite hierarchical pitch angle control for a tidal turbine based on the uncertainty and disturbance estimator

    Get PDF
    With the fast development of tidal turbines for sustainable energy generations, reliable and efficient tidal pitch systems are highly demanded. This paper presents a systematic design for a novel tidal pitch system based on hydraulic servo and bevel geared transmission. This system holds the characteristics of compact and triangular structure, making it easy to be installed in a narrow turbine hub. The pitch system dynamics are modelled by taking account of model uncertainties and external disturbances. An uncertainty and disturbance estimator (UDE)-based robust pitch control algorithm is developed to achieve effective pitch angle regulation, disturbance rejection and generator power smoothing. The UDE controller is designed in a composite hierarchical manner that includes an upper level power smoothing controller and a low level pitch angle tracking controller. The performance of the proposed pitch system and the UDE control is demonstrated through extensive simulation studies based on a 600 kW tidal turbine under varying tidal speeds. Compared with the conventional controller, the UDE based pitch controller can achieve more reliable power smoothing and pitch angle tracking with higher accuracy

    Uncertainty and Disturbance Estimator-Based Controller Equipped With a Time-Delayed Filter to Improve the Voltage Quality of Inverters

    Get PDF
    In this paper, a two-degrees-of-freedom control structure is proposed to minimize both total harmonic distortion and tracking error of inverter output voltage, adopting a resonant tracking controller and a modified uncertainty and disturbance estimator (UDE). Owing to the two-degree-of-freedom feature of the proposed control strategy, tracking and disturbance rejection tasks are decoupled and treated almost independently. A time-delay action is introduced into a commonly adopted low-pass UDE filter to minimize the output impedance magnitude around the odd harmonics, which is typical to nonlinear loads. Once the disturbance is properly rejected, a tracking resonant controller is designed to force the output of the nominal system to follow a sinusoidal reference with near-zero amplitude and phase error. The performance of the proposed control structure is fully verified by experimental results

    Uncertainty and disturbance estimator design to shape and reduce the output impedance of inverter

    Get PDF
    Power inverters are becoming more and more common in the modern grid. Due to their switching nature, a passive filter is installed at the inverter output. This generates high output impedance which limits the inverter ability to maintain high power quality at the inverter output. This thesis deals with an impedance shaping approach to the design of power inverter control. The Uncertainty and Disturbance Estimator (UDE) is proposed as a candidate for direct formation of the inverter output impedance. The selection of UDE is motivated by the desire for the disturbance rejection control and the tracking controller to be decoupled. It is demonstrated in the thesis that due to this fact the UDE filter design directly influences the inverter output impedance and the reference model determines the inverter internal electromotive force. It was recently shown in the literature and further emphasized in this thesis that the classic low pass frequency design of the UDE cannot estimate periodical disturbances under the constraint of finite control bandwidth. Since for a power inverter both the reference signal and the disturbance signal are of periodical nature, the classic UDE lowpass filter design does not give optimal results. A new design approach is therefore needed. The thesis develops four novel designs of the UDE filter to significantly reduce the inverter output impedance and maintain low Total Harmonic Distortion (THD) of the inverter output voltage. The first design is the based on a frequency selective filter. This filter design shows superiority in both observing and rejecting periodical disturbances over the classic low pass filter design. The second design uses a multi-band stop design to reject periodical disturbances with some uncertainty in the frequency. The third solution uses a classic low pass filter design combined with a time delay to match zero phase estimation of the disturbance at the relevant spectrum. Furthermore, this solution is combined with a resonant tracking controller to reduce the tracking steady-state error in the output voltage. The fourth solution utilizes a low-pass filter combined with multiple delays to increase the frequency robustness. This method shows superior performance over the multi-band-stop and the time delayed filter in steady-state. All the proposed methods are validated through extensive simulation and experimental results
    corecore