65 research outputs found

    Doctor of Philosophy

    Get PDF
    dissertationFor many with severe-to-profound hearing loss, a condition in which the cochlea is unable to convert sound vibration into neural information to the brain, the cochlear implant has become the standard treatment. The goal of a cochlear-implant system is to bypass the malfunctioned cochlea and directly stimulate the nerves responsible for hearing through an array of electrodes on a silicone-elastomer carrier. However, the insertion of the electrode arrays can often cause intracochlear damage and eliminate residual hearing. With increased focus on hearing preservation in cochlear implantation, methods to minimize intracochlear damage have become a priority in electrode-array insertions. This dissertation explores the application of magnetic manipulation toward improved cochlear-implant electrode-array insertions. We start with initial 3-to-1 proof-of-concept experiments to demonstrate the feasibility of this approach. Then, to achieve relevancy at clinical scale, lateral-wall-type electrode-array models, used in the clinic, are slightly modified at the tip to include a tiny magnet. Next, a scala-tympani phantom is designed with both simulated cochleostomy and round-window openings to mimic both classes of insertions typically conducted. In particular, this is the first phantom to model a round-window opening and can be used reliably to simulate insertion forces in cadaver cochleae. Electrode arrays are then magnetically guided through these phantoms with a statistically significant (p < 0.05) reduction in insertion forces, and by as much as 50% for some electrode-array models. In particular, guiding the electrode-array tip through the cochlear hook and the basal turn, in the same insertion, was demonstrated for the first time using this technology. All existing methods to guide the electrode array can only be accomplished for the basal turn. Analysis is conducted to determine the optimal size and placement of a magnetic dipole-field source for use in the clinic. Its placement is determined to be consistently lateral to and anterior to the patient’s cochlea. Its size depends on numerous factors including the patient, torque requirements, and registration error. Sensitivity curves summarizing these factors are provided. The volume of the magnetic dipole-field source can be reduced by a factor of 5, on average, by moving it from the modiolar configuration originally proposed to this optimal configuration. We verify that magnetic forces do not pose any appreciable risk to the basilar membrane at the optimal configuration. Although patient-specific optimal configurations are characterized, a one-size-fits-all version is described that may be more practical and carries the benefit of substantial robustness to registration error

    Automated analysis of human cochlea shape variability from segmented ÎĽCT images

    Get PDF
    International audienceThe aim of this study is to define an automated and reproducible framework for cochlear anatomical analysis from high-resolution segmented images and to provide a comprehensive and objective shape variability study suitable for cochlear implant design and surgery planning. For the scala tympani (ST), the scala vestibuli (SV) and the whole cochlea, the variability of the arc lengths and the radial and longitudinal components of the lateral, central and modiolar paths are studied. The robustness of the automated cochlear coordinate system estimation is validated with synthetic and real data. Cochlear cross-sections are statistically analyzed using area, height and width measurements. The cross-section tilt angle is objectively measured and this data documents a significant feature for occurrence of surgical trauma

    Postoperative Impedance-Based Estimation of Cochlear Implant Electrode Insertion Depth.

    Get PDF
    OBJECTIVES Reliable determination of cochlear implant electrode positions shows promise for clinical applications, including anatomy-based fitting of audio processors or monitoring of electrode migration during follow-up. Currently, electrode positioning is measured using radiography. The primary objective of this study is to extend and validate an impedance-based method for estimating electrode insertion depths, which could serve as a radiation-free and cost-effective alternative to radiography. The secondary objective is to evaluate the reliability of the estimation method in the postoperative follow-up over several months. DESIGN The ground truth insertion depths were measured from postoperative computed tomography scans obtained from the records of 56 cases with an identical lateral wall electrode array. For each of these cases, impedance telemetry records were retrieved starting from the day of implantation up to a maximum observation period of 60 mo. Based on these recordings, the linear and angular electrode insertion depths were estimated using a phenomenological model. The estimates obtained were compared with the ground truth values to calculate the accuracy of the model. RESULTS Analysis of the long-term recordings using a linear mixed-effects model showed that postoperative tissue resistances remained stable throughout the follow-up period, except for the two most basal electrodes, which increased significantly over time (electrode 11: ~10 Ω/year, electrode 12: ~30 Ω/year). Inferred phenomenological models from early and late impedance telemetry recordings were not different. The insertion depth of all electrodes was estimated with an absolute error of 0.9 mm ± 0.6 mm or 22° ± 18° angle (mean ± SD). CONCLUSIONS Insertion depth estimations of the model were reliable over time when comparing two postoperative computed tomography scans of the same ear. Our results confirm that the impedance-based position estimation method can be applied to postoperative impedance telemetry recordings. Future work needs to address extracochlear electrode detection to increase the performance of the method

    A Web-Based Automated Image Processing Research Platform for Cochlear Implantation-Related Studies

    Get PDF
    International audienceThe robust delineation of the cochlea and its inner structures combined with the detection of the electrode of a cochlear implant within these structures is essential for envisaging a safer, more individualized, routine image-guided cochlear implant therapy. We present Nautilus—a web-based research platform for automated pre- and post-implantation cochlear analysis. Nautilus delineates cochlear structures from pre-operative clinical CT images by combining deep learning and Bayesian inference approaches. It enables the extraction of electrode locations from a post-operative CT image using convolutional neural networks and geometrical inference. By fusing pre- and post-operative images, Nautilus is able to provide a set of personalized pre- and post-operative metrics that can serve the exploration of clinically relevant questions in cochlear implantation therapy. In addition, Nautilus embeds a self-assessment module providing a confidence rating on the outputs of its pipeline. We present a detailed accuracy and robustness analyses of the tool on a carefully designed dataset. The results of these analyses provide legitimate grounds for envisaging the implementation of image-guided cochlear implant practices into routine clinical workflows

    High Fidelity Bioelectric Modelling of the Implanted Cochlea

    Get PDF
    Cochlear implants are medical devices that can restore sound perception in individuals with sensorineural hearing loss (SHL). Since their inception, improvements in performance have largely been driven by advances in signal processing, but progress has plateaued for almost a decade. This suggests that there is a bottleneck at the electrode-tissue interface, which is responsible for enacting the biophysical changes that govern neuronal recruitment. Understanding this interface is difficult because the cochlea is small, intricate, and difficult to access. As such, researchers have turned to modelling techniques to provide new insights. The state-of-the-art involves calculating the electric field using a volume conduction model of the implanted cochlea and coupling it with a neural excitation model to predict the response. However, many models are unable to predict patient outcomes consistently. This thesis aims to improve the reliability of these models by creating high fidelity reconstructions of the inner ear and critically assessing the validity of the underlying and hitherto untested assumptions. Regarding boundary conditions, the evidence suggests that the unmodelled monopolar return path should be accounted for, perhaps by applying a voltage offset at a boundary surface. Regarding vasculature, the models show that large modiolar vessels like the vein of the scala tympani have a strong local effect near the stimulating electrode. Finally, it appears that the oft-cited quasi-static assumption is not valid due to the high permittivity of neural tissue. It is hoped that the study improves the trustworthiness of all bioelectric models of the cochlea, either by validating the claims of existing models, or by prompting improvements in future work. Developing our understanding of the underlying physics will pave the way for advancing future electrode array designs as well as patient-specific simulations, ultimately improving the quality of life for those with SHL

    In-Vitro Study of Speed and Alignment Angle in Cochlear Implant Electrode Array Insertions

    Get PDF
    Objective: The insertion of the electrode array is a critical step in cochlear implantation. Herein we comprehensively investigate the impact of the alignment angle and feed-forward speed on deep insertions in artificial scala tympani models with accurate macro-anatomy and controlled frictional properties. Methods: Motorized insertions (n=1033) were performed in six scala tympani models with varying speeds and alignment angles. We evaluated reaction forces and micrographs of the insertion process and developed a mathematical model to estimate the normal force distribution along the electrode arrays. Results: Insertions parallel to the cochlear base significantly reduce insertion energies and lead to smoother array movement. Non-constant insertion speeds allow to reduce insertion forces for a fixed total insertion time compared to a constant feed rate. Conclusion: In cochlear implantation, smoothness and peak forces can be reduced with alignment angles parallel to the scala tympani centerline and with non-constant feed-forward speed profiles. Significance: Our results may help to provide clinical guidelines and improve surgical tools for manual and automated cochlear implantation

    Evaluating and Improving Cochlear Length Measurements on Clinical Computed Tomography Images

    Get PDF
    Cochlear implants provide the sensation of sound to deaf individuals. An accurate estimate of cochlear duct length (CDL) is required for pre-operative implant electrode selection and can be obtained from clinical computed tomography (CT) by measuring the “A-value”. The objectives of this work were to estimate the accuracy and variability in manual A-value measurements, and to automate measurements. Four specialists repeatedly measured the A-value on clinical CT images from which the inter- and intra-observer variability were calculated. Accuracy was assessed by comparison to measurements on higher resolution micro-CT images. Motivated by this study, software was developed to automate the A-value measurement by registering an annotated atlas to unlabelled images. There was significant variability in manual A-value measurements made using either standard clinical or multi-planar reformatted views with the latter exhibiting higher variability but better accuracy. The automated approach eliminated variability and improved accuracy, enabling the correct selection of electrode length
    • …