2,639 research outputs found
Trainable COSFIRE filters for vessel delineation with application to retinal images
Retinal imaging provides a non-invasive opportunity for the diagnosis of several medical pathologies. The automatic segmentation of the vessel tree is an important pre-processing step which facilitates subsequent automatic processes that contribute to such diagnosis. We introduce a novel method for the automatic segmentation of vessel trees in retinal fundus images. We propose a filter that selectively responds to vessels and that we call B-COSFIRE with B standing for bar which is an abstraction for a vessel. It is based on the existing COSFIRE (Combination Of Shifted Filter Responses) approach. A B-COSFIRE filter achieves orientation selectivity by computing the weighted geometric mean of the output of a pool of Difference-of-Gaussians filters, whose supports are aligned in a collinear manner. It achieves rotation invariance efficiently by simple shifting operations. The proposed filter is versatile as its selectivity is determined from any given vessel-like prototype pattern in an automatic configuration process. We configure two B-COSFIRE filters, namely symmetric and asymmetric, that are selective for bars and bar-endings, respectively. We achieve vessel segmentation by summing up the responses of the two rotation-invariant B-COSFIRE filters followed by thresholding. The results that we achieve on three publicly available data sets (DRIVE: Se = 0.7655, Sp = 0.9704; STARE: Se = 0.7716, Sp = 0.9701; CHASE_DB1: Se = 0.7585, Sp = 0.9587) are higher than many of the state-of-the-art methods. The proposed segmentation approach is also very efficient with a time complexity that is significantly lower than existing methods.peer-reviewe
Recommended from our members
A model of ganglion axon pathways accounts for percepts elicited by retinal implants.
Degenerative retinal diseases such as retinitis pigmentosa and macular degeneration cause irreversible vision loss in more than 10 million people worldwide. Retinal prostheses, now implanted in over 250 patients worldwide, electrically stimulate surviving cells in order to evoke neuronal responses that are interpreted by the brain as visual percepts ('phosphenes'). However, instead of seeing focal spots of light, current implant users perceive highly distorted phosphenes that vary in shape both across subjects and electrodes. We characterized these distortions by asking users of the Argus retinal prosthesis system (Second Sight Medical Products Inc.) to draw electrically elicited percepts on a touchscreen. Using ophthalmic fundus imaging and computational modeling, we show that elicited percepts can be accurately predicted by the topographic organization of optic nerve fiber bundles in each subject's retina, successfully replicating visual percepts ranging from 'blobs' to oriented 'streaks' and 'wedges' depending on the retinal location of the stimulating electrode. This provides the first evidence that activation of passing axon fibers accounts for the rich repertoire of phosphene shape commonly reported in psychophysical experiments, which can severely distort the quality of the generated visual experience. Overall our findings argue for more detailed modeling of biological detail across neural engineering applications
Deep Learning in Cardiology
The medical field is creating large amount of data that physicians are unable
to decipher and use efficiently. Moreover, rule-based expert systems are
inefficient in solving complicated medical tasks or for creating insights using
big data. Deep learning has emerged as a more accurate and effective technology
in a wide range of medical problems such as diagnosis, prediction and
intervention. Deep learning is a representation learning method that consists
of layers that transform the data non-linearly, thus, revealing hierarchical
relationships and structures. In this review we survey deep learning
application papers that use structured data, signal and imaging modalities from
cardiology. We discuss the advantages and limitations of applying deep learning
in cardiology that also apply in medicine in general, while proposing certain
directions as the most viable for clinical use.Comment: 27 pages, 2 figures, 10 table
Retinal Vessel Segmentation Using the 2-D Morlet Wavelet and Supervised Classification
We present a method for automated segmentation of the vasculature in retinal
images. The method produces segmentations by classifying each image pixel as
vessel or non-vessel, based on the pixel's feature vector. Feature vectors are
composed of the pixel's intensity and continuous two-dimensional Morlet wavelet
transform responses taken at multiple scales. The Morlet wavelet is capable of
tuning to specific frequencies, thus allowing noise filtering and vessel
enhancement in a single step. We use a Bayesian classifier with
class-conditional probability density functions (likelihoods) described as
Gaussian mixtures, yielding a fast classification, while being able to model
complex decision surfaces and compare its performance with the linear minimum
squared error classifier. The probability distributions are estimated based on
a training set of labeled pixels obtained from manual segmentations. The
method's performance is evaluated on publicly available DRIVE and STARE
databases of manually labeled non-mydriatic images. On the DRIVE database, it
achieves an area under the receiver operating characteristic (ROC) curve of
0.9598, being slightly superior than that presented by the method of Staal et
al.Comment: 9 pages, 7 figures and 1 table. Accepted for publication in IEEE
Trans Med Imag; added copyright notic
A Method of Drusen Measurement Based on the Geometry of Fundus Reflectance
BACKGROUND: The hallmarks of age-related macular degeneration, the leading cause of blindness in the developed world, are the subretinal deposits known as drusen. Drusen identification and measurement play a key role in clinical studies of this disease. Current manual methods of drusen measurement are laborious and subjective. Our purpose was to expedite clinical research with an accurate, reliable digital method. METHODS: An interactive semi-automated procedure was developed to level the macular background reflectance for the purpose of morphometric analysis of drusen. 12 color fundus photographs of patients with age-related macular degeneration and drusen were analyzed. After digitizing the photographs, the underlying background pattern in the green channel was leveled by an algorithm based on the elliptically concentric geometry of the reflectance in the normal macula: the gray scale values of all structures within defined elliptical boundaries were raised sequentially until a uniform background was obtained. Segmentation of drusen and area measurements in the central and middle subfields (1000 μm and 3000 μm diameters) were performed by uniform thresholds. Two observers using this interactive semi-automated software measured each image digitally. The mean digital measurements were compared to independent stereo fundus gradings by two expert graders (stereo Grader 1 estimated the drusen percentage in each of the 24 regions as falling into one of four standard broad ranges; stereo Grader 2 estimated drusen percentages in 1% to 5% intervals). RESULTS: The mean digital area measurements had a median standard deviation of 1.9%. The mean digital area measurements agreed with stereo Grader 1 in 22/24 cases. The 95% limits of agreement between the mean digital area measurements and the more precise stereo gradings of Grader 2 were -6.4 % to +6.8 % in the central subfield and -6.0 % to +4.5 % in the middle subfield. The mean absolute differences between the digital and stereo gradings 2 were 2.8 +/- 3.4% in the central subfield and 2.2 +/- 2.7% in the middle subfield. CONCLUSIONS: Semi-automated, supervised drusen measurements may be done reproducibly and accurately with adaptations of commercial software. This technique for macular image analysis has potential for use in clinical research
Air pollution and the microvasculature: A cross-sectional assessment of in vivo retinal images in the population-based multi-ethnic study of atherosclerosis (MESA)
10.1371/journal.pmed.1000372PLoS Medicine711
Atypical presentation of neuronal ceroid lipofuscinosis type 8 in a sibling pair and review of the eye findings and neurological features.
Purpose:To report atypical presentation of neuronal ceroid lipofuscinoses type 8 (CLN8) to the eye clinic and review clinical features of CLN8. Observations:Detailed eye exam by slit lamp exam, indirect ophthalmoscopy, fundus photography, optical coherence tomography, visual fields and electroretinogram (ERG). Molecular genetic testing using Next Generation Sequencing panel (NGS) and array Comparative Genomic Hybridization (aCGH).The siblings in this study presented to the eye clinic with retinitis pigmentosa and cystoid macular edema, and a history of seizures but no severe neurocognitive deficits or regression. Genetic testing identified a c.200C > T (p.A67V) variant in the CLN8 gene and a deletion encompassing the entire gene. Electron microscopy of lymphocytes revealed fingerprint inclusions in both siblings. Conclusions:and Importance: Pathogenic variants in CLN8 account for the retinitis pigmentosa and seizures in our patients however, currently, they do not have regression or neurocognitive decline. The presentation of NCL can be very diverse and it is important for ophthalmologists to consider this in the differential diagnosis of retinal disorders with seizures or other neurological features. Molecular genetic testing of multiple genes causing isolated and syndromic eye disorders using NGS panels and aCGH along with additional complementary testing may often be required to arrive at a definitive diagnosis
- …