26,962 research outputs found

    Living Innovation Laboratory Model Design and Implementation

    Full text link
    Living Innovation Laboratory (LIL) is an open and recyclable way for multidisciplinary researchers to remote control resources and co-develop user centered projects. In the past few years, there were several papers about LIL published and trying to discuss and define the model and architecture of LIL. People all acknowledge about the three characteristics of LIL: user centered, co-creation, and context aware, which make it distinguished from test platform and other innovation approaches. Its existing model consists of five phases: initialization, preparation, formation, development, and evaluation. Goal Net is a goal-oriented methodology to formularize a progress. In this thesis, Goal Net is adopted to subtract a detailed and systemic methodology for LIL. LIL Goal Net Model breaks the five phases of LIL into more detailed steps. Big data, crowd sourcing, crowd funding and crowd testing take place in suitable steps to realize UUI, MCC and PCA throughout the innovation process in LIL 2.0. It would become a guideline for any company or organization to develop a project in the form of an LIL 2.0 project. To prove the feasibility of LIL Goal Net Model, it was applied to two real cases. One project is a Kinect game and the other one is an Internet product. They were both transformed to LIL 2.0 successfully, based on LIL goal net based methodology. The two projects were evaluated by phenomenography, which was a qualitative research method to study human experiences and their relations in hope of finding the better way to improve human experiences. Through phenomenographic study, the positive evaluation results showed that the new generation of LIL had more advantages in terms of effectiveness and efficiency.Comment: This is a book draf

    Towards a Practical Pedestrian Distraction Detection Framework using Wearables

    Full text link
    Pedestrian safety continues to be a significant concern in urban communities and pedestrian distraction is emerging as one of the main causes of grave and fatal accidents involving pedestrians. The advent of sophisticated mobile and wearable devices, equipped with high-precision on-board sensors capable of measuring fine-grained user movements and context, provides a tremendous opportunity for designing effective pedestrian safety systems and applications. Accurate and efficient recognition of pedestrian distractions in real-time given the memory, computation and communication limitations of these devices, however, remains the key technical challenge in the design of such systems. Earlier research efforts in pedestrian distraction detection using data available from mobile and wearable devices have primarily focused only on achieving high detection accuracy, resulting in designs that are either resource intensive and unsuitable for implementation on mainstream mobile devices, or computationally slow and not useful for real-time pedestrian safety applications, or require specialized hardware and less likely to be adopted by most users. In the quest for a pedestrian safety system that achieves a favorable balance between computational efficiency, detection accuracy, and energy consumption, this paper makes the following main contributions: (i) design of a novel complex activity recognition framework which employs motion data available from users' mobile and wearable devices and a lightweight frequency matching approach to accurately and efficiently recognize complex distraction related activities, and (ii) a comprehensive comparative evaluation of the proposed framework with well-known complex activity recognition techniques in the literature with the help of data collected from human subject pedestrians and prototype implementations on commercially-available mobile and wearable devices

    Privacy CURE: Consent Comprehension Made Easy

    Get PDF
    Although the General Data Protection Regulation (GDPR) defines several potential legal bases for personal data processing, in many cases data controllers, even when they are located outside the European Union (EU), will need to obtain consent from EU citizens for the processing of their personal data. Unfortunately, existing approaches for obtaining consent, such as pages of text followed by an agreement/disagreement mechanism, are neither specific nor informed. In order to address this challenge, we introduce our Consent reqUest useR intErface (CURE) prototype, which is based on the GDPR requirements and the interpretation of those requirements by the Article 29 Working Party (i.e., the predecessor of the European Data Protection Board). The CURE prototype provides transparency regarding personal data processing, more control via a customization, and, based on the results of our usability evaluation, improves user comprehension with respect to what data subjects actually consent to. Although the CURE prototype is based on the GDPR requirements, it could potentially be used in other jurisdictions also

    Vector processing-aware advanced clock-gating techniques for low-power fused multiply-add

    Get PDF
    The need for power efficiency is driving a rethink of design decisions in processor architectures. While vector processors succeeded in the high-performance market in the past, they need a retailoring for the mobile market that they are entering now. Floating-point (FP) fused multiply-add (FMA), being a functional unit with high power consumption, deserves special attention. Although clock gating is a well-known method to reduce switching power in synchronous designs, there are unexplored opportunities for its application to vector processors, especially when considering active operating mode. In this research, we comprehensively identify, propose, and evaluate the most suitable clock-gating techniques for vector FMA units (VFUs). These techniques ensure power savings without jeopardizing the timing. We evaluate the proposed techniques using both synthetic and “real-world” application-based benchmarking. Using vector masking and vector multilane-aware clock gating, we report power reductions of up to 52%, assuming active VFU operating at the peak performance. Among other findings, we observe that vector instruction-based clock-gating techniques achieve power savings for all vector FP instructions. Finally, when evaluating all techniques together, using “real-world” benchmarking, the power reductions are up to 80%. Additionally, in accordance with processor design trends, we perform this research in a fully parameterizable and automated fashion.The research leading to these results has received funding from the RoMoL ERC Advanced Grant GA 321253 and is supported in part by the European Union (FEDER funds) under contract TTIN2015-65316-P. The work of I. Ratkovic was supported by a FPU research grant from the Spanish MECD.Peer ReviewedPostprint (author's final draft

    Survey of End-to-End Mobile Network Measurement Testbeds, Tools, and Services

    Full text link
    Mobile (cellular) networks enable innovation, but can also stifle it and lead to user frustration when network performance falls below expectations. As mobile networks become the predominant method of Internet access, developer, research, network operator, and regulatory communities have taken an increased interest in measuring end-to-end mobile network performance to, among other goals, minimize negative impact on application responsiveness. In this survey we examine current approaches to end-to-end mobile network performance measurement, diagnosis, and application prototyping. We compare available tools and their shortcomings with respect to the needs of researchers, developers, regulators, and the public. We intend for this survey to provide a comprehensive view of currently active efforts and some auspicious directions for future work in mobile network measurement and mobile application performance evaluation.Comment: Submitted to IEEE Communications Surveys and Tutorials. arXiv does not format the URL references correctly. For a correctly formatted version of this paper go to http://www.cs.montana.edu/mwittie/publications/Goel14Survey.pd
    • …
    corecore