2,267 research outputs found

    Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates

    Get PDF
    The study of cerebral anatomy in developing neonates is of great importance for the understanding of brain development during the early period of life. This dissertation therefore focuses on three challenges in the modelling of cerebral anatomy in neonates during brain development. The methods that have been developed all use Magnetic Resonance Images (MRI) as source data. To facilitate study of vascular development in the neonatal period, a set of image analysis algorithms are developed to automatically extract and model cerebral vessel trees. The whole process consists of cerebral vessel tracking from automatically placed seed points, vessel tree generation, and vasculature registration and matching. These algorithms have been tested on clinical Time-of- Flight (TOF) MR angiographic datasets. To facilitate study of the neonatal cortex a complete cerebral cortex segmentation and reconstruction pipeline has been developed. Segmentation of the neonatal cortex is not effectively done by existing algorithms designed for the adult brain because the contrast between grey and white matter is reversed. This causes pixels containing tissue mixtures to be incorrectly labelled by conventional methods. The neonatal cortical segmentation method that has been developed is based on a novel expectation-maximization (EM) method with explicit correction for mislabelled partial volume voxels. Based on the resulting cortical segmentation, an implicit surface evolution technique is adopted for the reconstruction of the cortex in neonates. The performance of the method is investigated by performing a detailed landmark study. To facilitate study of cortical development, a cortical surface registration algorithm for aligning the cortical surface is developed. The method first inflates extracted cortical surfaces and then performs a non-rigid surface registration using free-form deformations (FFDs) to remove residual alignment. Validation experiments using data labelled by an expert observer demonstrate that the method can capture local changes and follow the growth of specific sulcus

    Three--dimensional medical imaging: Algorithms and computer systems

    Get PDF
    This paper presents an introduction to the field of three-dimensional medical imaging It presents medical imaging terms and concepts, summarizes the basic operations performed in three-dimensional medical imaging, and describes sample algorithms for accomplishing these operations. The paper contains a synopsis of the architectures and algorithms used in eight machines to render three-dimensional medical images, with particular emphasis paid to their distinctive contributions. It compares the performance of the machines along several dimensions, including image resolution, elapsed time to form an image, imaging algorithms used in the machine, and the degree of parallelism used in the architecture. The paper concludes with general trends for future developments in this field and references on three-dimensional medical imaging

    Coronary Artery Centerline Extraction in Cardiac CT Angiography Using a CNN-Based Orientation Classifier

    Full text link
    Coronary artery centerline extraction in cardiac CT angiography (CCTA) images is a prerequisite for evaluation of stenoses and atherosclerotic plaque. We propose an algorithm that extracts coronary artery centerlines in CCTA using a convolutional neural network (CNN). A 3D dilated CNN is trained to predict the most likely direction and radius of an artery at any given point in a CCTA image based on a local image patch. Starting from a single seed point placed manually or automatically anywhere in a coronary artery, a tracker follows the vessel centerline in two directions using the predictions of the CNN. Tracking is terminated when no direction can be identified with high certainty. The CNN was trained using 32 manually annotated centerlines in a training set consisting of 8 CCTA images provided in the MICCAI 2008 Coronary Artery Tracking Challenge (CAT08). Evaluation using 24 test images of the CAT08 challenge showed that extracted centerlines had an average overlap of 93.7% with 96 manually annotated reference centerlines. Extracted centerline points were highly accurate, with an average distance of 0.21 mm to reference centerline points. In a second test set consisting of 50 CCTA scans, 5,448 markers in the coronary arteries were used as seed points to extract single centerlines. This showed strong correspondence between extracted centerlines and manually placed markers. In a third test set containing 36 CCTA scans, fully automatic seeding and centerline extraction led to extraction of on average 92% of clinically relevant coronary artery segments. The proposed method is able to accurately and efficiently determine the direction and radius of coronary arteries. The method can be trained with limited training data, and once trained allows fast automatic or interactive extraction of coronary artery trees from CCTA images.Comment: Accepted in Medical Image Analysi

    Feature-driven Volume Visualization of Medical Imaging Data

    Get PDF
    Direct volume rendering (DVR) is a volume visualization technique that has been proved to be a very powerful tool in many scientific visualization domains. Diagnostic medical imaging is one such domain in which DVR provides new capabilities for the analysis of complex cases and improves the efficiency of image interpretation workflows. However, the full potential of DVR in the medical domain has not yet been realized. A major obstacle for a better integration of DVR in the medical domain is the time-consuming process to optimize the rendering parameters that are needed to generate diagnostically relevant visualizations in which the important features that are hidden in image volumes are clearly displayed, such as shape and spatial localization of tumors, its relationship with adjacent structures, and temporal changes in the tumors. In current workflows, clinicians must manually specify the transfer function (TF), view-point (camera), clipping planes, and other visual parameters. Another obstacle for the adoption of DVR to the medical domain is the ever increasing volume of imaging data. The advancement of imaging acquisition techniques has led to a rapid expansion in the size of the data, in the forms of higher resolutions, temporal imaging acquisition to track treatment responses over time, and an increase in the number of imaging modalities that are used for a single procedure. The manual specification of the rendering parameters under these circumstances is very challenging. This thesis proposes a set of innovative methods that visualize important features in multi-dimensional and multi-modality medical images by automatically or semi-automatically optimizing the rendering parameters. Our methods enable visualizations necessary for the diagnostic procedure in which 2D slice of interest (SOI) can be augmented with 3D anatomical contextual information to provide accurate spatial localization of 2D features in the SOI; the rendering parameters are automatically computed to guarantee the visibility of 3D features; and changes in 3D features can be tracked in temporal data under the constraint of consistent contextual information. We also present a method for the efficient computation of visibility histograms (VHs) using adaptive binning, which allows our optimal DVR to be automated and visualized in real-time. We evaluated our methods by producing visualizations for a variety of clinically relevant scenarios and imaging data sets. We also examined the computational performance of our methods for these scenarios

    Feature-driven Volume Visualization of Medical Imaging Data

    Get PDF
    Direct volume rendering (DVR) is a volume visualization technique that has been proved to be a very powerful tool in many scientific visualization domains. Diagnostic medical imaging is one such domain in which DVR provides new capabilities for the analysis of complex cases and improves the efficiency of image interpretation workflows. However, the full potential of DVR in the medical domain has not yet been realized. A major obstacle for a better integration of DVR in the medical domain is the time-consuming process to optimize the rendering parameters that are needed to generate diagnostically relevant visualizations in which the important features that are hidden in image volumes are clearly displayed, such as shape and spatial localization of tumors, its relationship with adjacent structures, and temporal changes in the tumors. In current workflows, clinicians must manually specify the transfer function (TF), view-point (camera), clipping planes, and other visual parameters. Another obstacle for the adoption of DVR to the medical domain is the ever increasing volume of imaging data. The advancement of imaging acquisition techniques has led to a rapid expansion in the size of the data, in the forms of higher resolutions, temporal imaging acquisition to track treatment responses over time, and an increase in the number of imaging modalities that are used for a single procedure. The manual specification of the rendering parameters under these circumstances is very challenging. This thesis proposes a set of innovative methods that visualize important features in multi-dimensional and multi-modality medical images by automatically or semi-automatically optimizing the rendering parameters. Our methods enable visualizations necessary for the diagnostic procedure in which 2D slice of interest (SOI) can be augmented with 3D anatomical contextual information to provide accurate spatial localization of 2D features in the SOI; the rendering parameters are automatically computed to guarantee the visibility of 3D features; and changes in 3D features can be tracked in temporal data under the constraint of consistent contextual information. We also present a method for the efficient computation of visibility histograms (VHs) using adaptive binning, which allows our optimal DVR to be automated and visualized in real-time. We evaluated our methods by producing visualizations for a variety of clinically relevant scenarios and imaging data sets. We also examined the computational performance of our methods for these scenarios

    Dynamic Volume Rendering of Functional Medical Data on Dissimilar Hardware Platforms

    Get PDF
    In the last 30 years, medical imaging has become one of the most used diagnostic tools in the medical profession. Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) technologies have become widely adopted because of their ability to capture the human body in a non-invasive manner. A volumetric dataset is a series of orthogonal 2D slices captured at a regular interval, typically along the axis of the body from the head to the feet. Volume rendering is a computer graphics technique that allows volumetric data to be visualized and manipulated as a single 3D object. Iso-surface rendering, image splatting, shear warp, texture slicing, and raycasting are volume rendering methods, each with associated advantages and disadvantages. Raycasting is widely regarded as the highest quality renderer of these methods. Originally, CT and MRI hardware was limited to providing a single 3D scan of the human body. The technology has improved to allow a set of scans capable of capturing anatomical movements like a beating heart. The capturing of anatomical data over time is referred to as functional imaging. Functional MRI (fMRI) is used to capture changes in the human body over time. While fMRI’s can be used to capture any anatomical data over time, one of the more common uses of fMRI is to capture brain activity. The fMRI scanning process is typically broken up into a time consuming high resolution anatomical scan and a series of quick low resolution scans capturing activity. The low resolution activity data is mapped onto the high resolution anatomical data to show changes over time. Academic research has advanced volume rendering and specifically fMRI volume rendering. Unfortunately, academic research is typically a one-off solution to a singular medical case or set of data, causing any advances to be problem specific as opposed to a general capability. Additionally, academic volume renderers are often designed to work on a specific device and operating system under controlled conditions. This prevents volume rendering from being used across the ever expanding number of different computing devices, such as desktops, laptops, immersive virtual reality systems, and mobile computers like phones or tablets. This research will investigate the feasibility of creating a generic software capability to perform real-time 4D volume rendering, via raycasting, on desktop, mobile, and immersive virtual reality platforms. Implementing a GPU-based 4D volume raycasting method for mobile devices will harness the power of the increasing number of mobile computational devices being used by medical professionals. Developing support for immersive virtual reality can enhance medical professionals’ interpretation of 3D physiology with the additional depth information provided by stereoscopic 3D. The results of this research will help expand the use of 4D volume rendering beyond the traditional desktop computer in the medical field. Developing the same 4D volume rendering capabilities across dissimilar platforms has many challenges. Each platform relies on their own coding languages, libraries, and hardware support. There are tradeoffs between using languages and libraries native to each platform and using a generic cross-platform system, such as a game engine. Native libraries will generally be more efficient during application run-time, but they require different coding implementations for each platform. The decision was made to use platform native languages and libraries in this research, whenever practical, in an attempt to achieve the best possible frame rates. 4D volume raycasting provides unique challenges independent of the platform. Specifically, fMRI data loading, volume animation, and multiple volume rendering. Additionally, real-time raycasting has never been successfully performed on a mobile device. Previous research relied on less computationally expensive methods, such as orthogonal texture slicing, to achieve real-time frame rates. These challenges will be addressed as the contributions of this research. The first contribution was exploring the feasibility of generic functional data input across desktop, mobile, and immersive virtual reality. To visualize 4D fMRI data it was necessary to build in the capability to read Neuroimaging Informatics Technology Initiative (NIfTI) files. The NIfTI format was designed to overcome limitations of 3D file formats like DICOM and store functional imagery with a single high-resolution anatomical scan and a set of low-resolution anatomical scans. Allowing input of the NIfTI binary data required creating custom C++ routines, as no object oriented APIs freely available for use existed. The NIfTI input code was built using C++ and the C++ Standard Library to be both light weight and cross-platform. Multi-volume rendering is another challenge of fMRI data visualization and a contribution of this work. fMRI data is typically broken into a single high-resolution anatomical volume and a series of low-resolution volumes that capture anatomical changes. Visualizing two volumes at the same time is known as multi-volume visualization. Therefore, the ability to correctly align and scale the volumes relative to each other was necessary. It was also necessary to develop a compositing method to combine data from both volumes into a single cohesive representation. Three prototype applications were built for the different platforms to test the feasibility of 4D volume raycasting. One each for desktop, mobile, and virtual reality. Although the backend implementations were required to be different between the three platforms, the raycasting functionality and features were identical. Therefore, the same fMRI dataset resulted in the same 3D visualization independent of the platform itself. Each platform uses the same NIfTI data loader and provides support for dataset coloring and windowing (tissue density manipulation). The fMRI data can be viewed changing over time by either animation through the time steps, like a movie, or using an interface slider to “scrub” through the different time steps of the data. The prototype applications data load times and frame rates were tested to determine if they achieved the real-time interaction goal. Real-time interaction was defined by achieving 10 frames per second (fps) or better, based on the work of Miller [1]. The desktop version was evaluated on a 2013 MacBook Pro running OS X 10.12 with a 2.6 GHz Intel Core i7 processor, 16 GB of RAM, and a NVIDIA GeForce GT 750M graphics card. The immersive application was tested in the C6 CAVE™, a 96 graphics node computer cluster comprised of NVIDIA Quadro 6000 graphics cards running Red Hat Enterprise Linux. The mobile application was evaluated on a 2016 9.7” iPad Pro running iOS 9.3.4. The iPad had a 64-bit Apple A9X dual core processor with 2 GB of built in memory. Two different fMRI brain activity datasets with different voxel resolutions were used as test datasets. Datasets were tested using both the 3D structural data, the 4D functional data, and a combination of the two. Frame rates for the desktop implementation were consistently above 10 fps, indicating that real-time 4D volume raycasting is possible on desktop hardware. The mobile and virtual reality platforms were able to perform real-time 3D volume raycasting consistently. This is a marked improvement for 3D mobile volume raycasting that was previously only able to achieve under one frame per second [2]. Both VR and mobile platforms were able to raycast the 4D only data at real-time frame rates, but did not consistently meet 10 fps when rendering both the 3D structural and 4D functional data simultaneously. However, 7 frames per second was the lowest frame rate recorded, indicating that hardware advances will allow consistent real-time raycasting of 4D fMRI data in the near future

    Interactive Visualization of Multimodal Brain Connectivity: Applications in Clinical and Cognitive Neuroscience

    Get PDF
    Magnetic resonance imaging (MRI) has become a readily available prognostic and diagnostic method, providing invaluable information for the clinical treatment of neurological diseases. Multimodal neuroimaging allows integration of complementary data from various aspects such as functional and anatomical properties; thus, it has the potential to overcome the limitations of each individual modality. Specifically, functional and diffusion MRI are two non-invasive neuroimaging techniques customized to capture brain activity and microstructural properties, respectively. Data from these two modalities is inherently complex, and interactive visualization can assist with data comprehension. The current thesis presents the design, development, and validation of visualization and computation approaches that address the need for integration of brain connectivity from functional and structural domains. Two contexts were considered to develop these approaches: neuroscience exploration and minimally invasive neurosurgical planning. The goal was to provide novel visualization algorithms and gain new insights into big and complex data (e.g., brain networks) by visual analytics. This goal was achieved through three steps: 3D Graphical Collision Detection: One of the primary challenges was the timely rendering of grey matter (GM) regions and white matter (WM) fibers based on their 3D spatial maps. This challenge necessitated pre-scanning those objects to generate a memory array containing their intersections with memory units. This process helped faster retrieval of GM and WM virtual models during the user interactions. Neuroscience Enquiry (MultiXplore): A software interface was developed to display and react to user inputs by means of a connectivity matrix. This matrix displays connectivity information and is capable to accept selections from users and display the relevant ones in 3D anatomical view (with associated anatomical elements). In addition, this package can load multiple matrices from dynamic connectivity methods and annotate brain fibers. Neurosurgical Planning (NeuroPathPlan): A computational method was provided to map the network measures to GM and WM; thus, subject-specific eloquence metric can be derived from related resting state networks and used in objective assessment of cortical and subcortical tissue. This metric was later compared to apriori knowledge based decisions from neurosurgeons. Preliminary results show that eloquence metric has significant similarities with expert decisions

    Medical Data Visual Synchronization and Information interaction Using Internet-based Graphics Rendering and Message-oriented Streaming

    Get PDF
    The rapid technology advances in medical devices make possible the generation of vast amounts of data, which contain massive quantities of diagnostic information. Interactively accessing and sharing the acquired data on the Internet is critically important in telemedicine. However, due to the lack of efficient algorithms and high computational cost, collaborative medical data exploration on the Internet is still a challenging task in clinical settings. Therefore, we develop a web-based medical image rendering and visual synchronization software platform, in which novel algorithms are created for parallel data computing and image feature enhancement, where Node.js and Socket.IO libraries are utilized to establish bidirectional connections between server and clients in real time. In addition, we design a new methodology to stream medical information among all connected users, whose identities and input messages can be automatically stored in database and extracted in web browsers. The presented software framework will provide multiple medical practitioners with immediate visual feedback and interactive information in applications such as collaborative therapy planning, distributed treatment, and remote clinical health care
    • …
    corecore