992 research outputs found

    Breast Cancer: Modelling and Detection

    Get PDF
    This paper reviews a number of the mathematical models used in cancer modelling and then chooses a specific cancer, breast carcinoma, to illustrate how the modelling can be used in aiding detection. We then discuss mathematical models that underpin mammographic image analysis, which complements models of tumour growth and facilitates diagnosis and treatment of cancer. Mammographic images are notoriously difficult to interpret, and we give an overview of the primary image enhancement technologies that have been introduced, before focusing on a more detailed description of some of our own recent work on the use of physics-based modelling in mammography. This theoretical approach to image analysis yields a wealth of information that could be incorporated into the mathematical models, and we conclude by describing how current mathematical models might be enhanced by use of this information, and how these models in turn will help to meet some of the major challenges in cancer detection

    Can high-frequency ultrasound predict metastatic lymph nodes in patients with invasive breast cancer?

    Get PDF
    Aim To determine whether high-frequency ultrasound can predict the presence of metastatic axillary lymph nodes, with a high specificity and positive predictive value, in patients with invasive breast cancer. The clinical aim is to identify patients with axillary disease requiring surgery who would not normally, on clinical grounds, have an axillary dissection, so potentially improving outcome and survival rates. Materials and methods The ipsilateral and contralateral axillae of 42 consecutive patients with invasive breast cancer were scanned prior to treatment using a B-mode frequency of 13 MHz and a Power Doppler frequency of 7 MHz. The presence or absence of an echogenic centre for each lymph node detected was recorded, and measurements were also taken to determine the L/S ratio and the widest and narrowest part of the cortex. Power Doppler was also used to determine vascularity. The contralateral axilla was used as a control for each patient. Results In this study of patients with invasive breast cancer, ipsilateral lymph nodes with a cortical bulge ≥3 mm and/or at least two lymph nodes with absent echogenic centres indicated the presence of metastatic axillary lymph nodes (10 patients). The sensitivity and specificity were 52.6% and 100%, respectively, positive and negative predictive values were 100% and 71.9%, respectively, the P value was 0.001 and the Kappa score was 0.55.\ud Conclusion This would indicate that high-frequency ultrasound can be used to accurately predict metastatic lymph nodes in a proportion of patients with invasive breast cancer, which may alter patient management

    Are mammography image acquisition factors, compression pressure and paddle tilt, associated with breast cancer detection in screening?

    Get PDF
    Objectives: To assess the associations between objectively measured mammographic compression pressure and paddle tilt and breast cancer (BC) detected at the same (“contemporaneous”) screen, subsequent screens, or in-between screens (interval cancers). Methods: Automated pressure and paddle tilt estimates were derived for 80,495 mammographic examina-tions in a UK population-based screening programme. Adjusted logistic regression models were fitted to estimate the associations of compression parameters with BC detected at contemporaneous screen (777 cases). Nested case-control designs were used to estimate associations of pressure and tilt with: (a) interval cancer (148 cases/625 age-matched controls) and (b) subsequent screen-detected cancer (344/1436), via condi-tional logistic regression. Results: Compression pressure was negatively associated with odds of BC at contemporaneous screen (odds ratio (OR) for top versus bottom third of the pressure distribution: 0.74; 95% CI 0.60, 0.92; P-for-linear-trend (Pt) = 0.007). There was weak evidence that moderate pressure at screening was associated with lower odds of interval cancer (OR for middle versus bottom third: 0.63; 95% CI 0.38, 1.05; p = 0.079), but no association was found between pressure and the odds of BC at subsequent screen. There was no evidence that paddle tilt was associated with the odds of contemporaneous, subsequent screen or interval cancer detection. Conclusions: Findings are consistent with compression pressure, but not paddle tilt, affecting the performance of mammographic screening by interfering with its ability to detect cancers. Advances in knowledge: Inadequate or excessive compression pressure at screening may contribute to a reduced ability to detect cancers, resulting in a greater number of interval cancer cases

    Clinical assessment of image quality, usability and patient comfort in dedicated spiral breast computed tomography

    Full text link
    Objective: To investigate aspects of image quality, feasibility and patient comfort in dedicated spiral breast computed tomography (B-CT) in a large patient cohort. Methods: This retrospective study was approved by the institutional review board. 2418 B-CT scans from 1222 women examined between 04/16/2019 and 04/13/2022 were analyzed. Patients evaluated their comfort during the examination, radiographers carrying out the scans evaluated the patient's mobility and usability of the B-CT device, whereas radiologists assessed lesion contrast, detectability of calcifications, breast coverage and overall image quality. For semi-quantitative assessment, a Likert-Scale was used and statistical significance and correlations were calculated using ANOVAs and Spearman tests. Results: Comfort, mobility and usability of the B-CT were rated each with either "no" or "negligible" complaints in >99%. Image quality was rated with "no" or "negligible complaints" in 96.7%. Lesion contrast and detectability of calcifications were rated either "optimal" or "good" in 92.6% and 98.4%. "Complete" and "almost complete" breast coverage were reported in 41.9%, while the pectoral muscle was found not to be covered in 56.0%. Major parts of the breast were not covered in 2.1%. Some variables were significantly correlated, such as age with comfort (ρ = -0.168, p < .001) and mobility (ρ = -0.172, p < .001) as well as patient weight with lesion contrast (ρ = 0.172, p < .001) and breast coverage (ρ = -0.109, p < .001). Conclusions: B-CT provides high image quality and contrast of soft tissue lesions as well as calcifications, while covering the pre-pectoral areas of the breast remains challenging. B-CT is easy to operate for the radiographer and comfortable for the majority of women. Keywords: Breast; Breast neoplasms; Mammography; Spiral computed; Tomograph

    Clinical assessment of image quality, usability and patient comfort in dedicated spiral breast computed tomography

    Full text link
    OBJECTIVE To investigate aspects of image quality, feasibility and patient comfort in dedicated spiral breast computed tomography (B-CT) in a large patient cohort. METHODS This retrospective study was approved by the institutional review board. 2418 B-CT scans from 1222 women examined between 04/16/2019 and 04/13/2022 were analyzed. Patients evaluated their comfort during the examination, radiographers carrying out the scans evaluated the patient's mobility and usability of the B-CT device, whereas radiologists assessed lesion contrast, detectability of calcifications, breast coverage and overall image quality. For semi-quantitative assessment, a Likert-Scale was used and statistical significance and correlations were calculated using ANOVAs and Spearman tests. RESULTS Comfort, mobility and usability of the B-CT were rated each with either "no" or "negligible" complaints in >99%. Image quality was rated with "no" or "negligible complaints" in 96.7%. Lesion contrast and detectability of calcifications were rated either "optimal" or "good" in 92.6% and 98.4%. "Complete" and "almost complete" breast coverage were reported in 41.9%, while the pectoral muscle was found not to be covered in 56.0%. Major parts of the breast were not covered in 2.1%. Some variables were significantly correlated, such as age with comfort (ρ = -0.168, p < .001) and mobility (ρ = -0.172, p < .001) as well as patient weight with lesion contrast (ρ = 0.172, p < .001) and breast coverage (ρ = -0.109, p < .001). CONCLUSIONS B-CT provides high image quality and contrast of soft tissue lesions as well as calcifications, while covering the pre-pectoral areas of the breast remains challenging. B-CT is easy to operate for the radiographer and comfortable for the majority of women

    Mammography

    Get PDF
    In this volume, the topics are constructed from a variety of contents: the bases of mammography systems, optimization of screening mammography with reference to evidence-based research, new technologies of image acquisition and its surrounding systems, and case reports with reference to up-to-date multimodality images of breast cancer. Mammography has been lagged in the transition to digital imaging systems because of the necessity of high resolution for diagnosis. However, in the past ten years, technical improvement has resolved the difficulties and boosted new diagnostic systems. We hope that the reader will learn the essentials of mammography and will be forward-looking for the new technologies. We want to express our sincere gratitude and appreciation?to all the co-authors who have contributed their work to this volume
    • …
    corecore