8,575 research outputs found

    NIR Calibrations for Soybean Seeds and Soy Food Composition Analysis: Total Carbohydrates, Oil, Proteins and Water Contents

    Get PDF
    Conventional chemical analysis techniques are expensive, time consuming, and often destructive. The non-invasive Near Infrared (NIR) technology was introduced over the last decades for wide-scale, inexpensive chemical analysis of food and crop seed composition (see Williams and Norris, 1987; Wilcox and Cavins, 1995; Buning and Diller, 2000 for reviews of the NIR technique development stage prior to 1998, when Diode Arrays were introduced to NIR). NIR spectroscopic measurements obey Lambert and Beer’s law, and quantitative measurements can be successfully made with high speed and ease of operation. NIR has been used in a great variety of food applications. General applications of products analyzed come from all sectors of the food industry including meats, grains, and dairy products (Shadow, 1998)

    NIR Calibrations for Soybean Seeds and Soy Food Composition Analysis: Total Carbohydrates, Oil, Proteins and Water Contents [v.2]

    Get PDF
    Conventional chemical analysis techniques are expensive, time consuming, and often destructive. The non-invasive Near Infrared (NIR) technology was introduced over the last decades for wide-scale, inexpensive chemical analysis of food and crop seed composition (see Williams and Norris, 1987; Wilcox and Cavins, 1995; Buning and Diller, 2000 for reviews of the NIR technique development stage prior to 1998, when Diode Arrays were introduced to NIR). NIR spectroscopic measurements obey Lambert and Beer’s law, and quantitative measurements can be successfully made with high speed and ease of operation. NIR has been used in a great variety of food applications. General applications of products analyzed come from all sectors of the food industry including meats, grains, and dairy products (Shadow, 1998).
Novel NIR calibrations for rapid, reliable and accurate composition analysis of a variety of several soy based foods and bulk soybean seeds were developed and validated in a six-year collaborative project with a large number of different samples (N >~12, 000). The availability of such calibrations is important for establishing NIR as a secondary method for composition analysis of foods and soybeans both in applications and fundamental research

    Complexity in forecasting and predictive models

    Get PDF
    Te challenge of this special issue has been to know the state of the problem related to forecasting modeling and the creation of a model to forecast the future behavior that supports decision making by supporting real-world applications. Tis issue has been highlighted by the quality of its research work on the critical importance of advanced analytical methods, such as neural networks, sof computing, evolutionary algorithms, chaotic models, cellular automata, agent-based models, and fnite mixture minimum squares (FIMIX-PLS).info:eu-repo/semantics/publishedVersio

    Hyperspectral imaging applied to end-of-life (EOL) concrete recycling

    Get PDF
    The recovery of materials from DW is an important target of the recycling industry and it is important to know which materials are presents in order to set up efficient sorting and/or quality control actions. The implementation of an automatic recognition system of recovered products from End-Of-Life (EOL) concrete materials can be an useful way to maximize DW conversion into secondary raw materials. In this paper a new approach, based on HyperSpectral Imaging (HSI) sensors, is investigated in order to develop suitable and low cost strategies finalized to the preliminary detection and characterization of materials constituting Demolition Waste (DW) flow stream. The described HSI quality control approach is based on the utilization of a device working in the near infrared range (1000-1700 nm). Acquired hyperspectral images were analyzed. Different chemometric methods were applied. Results showed that it is possible to recognize DW materials and to distinguish the recycled aggregates from the investigated contaminants (brick, gypsum, plastic, wood and foam)

    Multivariate Statistical Process Control Charts: An Overview

    Get PDF
    In this paper we discuss the basic procedures for the implementation of multivariate statistical process control via control charting. Furthermore, we review multivariate extensions for all kinds of univariate control charts, such as multivariate Shewhart-type control charts, multivariate CUSUM control charts and multivariate EWMA control charts. In addition, we review unique procedures for the construction of multivariate control charts, based on multivariate statistical techniques such as principal components analysis (PCA) and partial lest squares (PLS). Finally, we describe the most significant methods for the interpretation of an out-of-control signal.quality control, process control, multivariate statistical process control, Hotelling's T-square, CUSUM, EWMA, PCA, PLS

    Statistical process monitoring of a multiphase flow facility

    Get PDF
    Industrial needs are evolving fast towards more flexible manufacture schemes. As a consequence, it is often required to adapt the plant production to the demand, which can be volatile depending on the application. This is why it is important to develop tools that can monitor the condition of the process working under varying operational conditions. Canonical Variate Analysis (CVA) is a multivariate data driven methodology which has been demonstrated to be superior to other methods, particularly under dynamically changing operational conditions. These comparative studies normally use computer simulated data in benchmark case studies such as the Tennessee Eastman Process Plant (Ricker, N.L. Tennessee Eastman Challenge Archive, Available at 〈http://depts.washington.edu/control/LARRY/TE/download.html〉 Accessed 21.03.2014). The aim of this work is to provide a benchmark case to demonstrate the ability of different monitoring techniques to detect and diagnose artificially seeded faults in an industrial scale multiphase flow experimental rig. The changing operational conditions, the size and complexity of the test rig make this case study an ideal candidate for a benchmark case that provides a test bed for the evaluation of novel multivariate process monitoring techniques performance using real experimental data. In this paper, the capabilities of CVA to detect and diagnose faults in a real system working under changing operating conditions are assessed and compared with other methodologies. The results obtained demonstrate that CVA can be effectively applied for the detection and diagnosis of faults in real complex systems, and reinforce the idea that the performance of CVA is superior to other algorithms
    corecore