539 research outputs found

    Construction and characterization of a phototherapy radiometer for optical radiation measurements

    Get PDF
    It is necessary to measure the irradiance levels to evaluate the effective dose delivered to the neonate from phototherapy devices. For such purpose, a broadband phototherapy radiometer has been used for measuring these phototherapy irradiance doses of plurality types of phototherapy sources. A phototherapy radiometer has been designed and during the construction its optical characteristics has been tested in collaboration between the National Institute of Standards in Egypt (NIS) and Department of Research And Development, Medical Engineering Group (MEG) Company. The most parameters required to characterize the performance of radiometer are the responsivity and uniformity. Then the present radiometer has been compared to other two available portable phototherapy radiometers in irradiance levels measurement. The calibration has been settled and the expanded uncertainties has been calculated according to the Guide to the expression of uncertainty in measurement (GUM) at coverage factor k = 2. The designed radiometer has responsivity range 415-495 nm with FWHM 35 nm which covers the phototherapy blue band. The radiometer results output summarized as; quantum efficiency is 84%, the uniformity 72% and measuring irradiance range 100-2500 µW.cm-2

    On-scalp MEG sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration

    Get PDF
    Source modelling in magnetoencephalography (MEG) requires precise co-registration of the sensor array and the anatomical structure of the measured individual\u27s head. In conventional MEG, the positions and orientations of the sensors relative to each other are fixed and known beforehand, requiring only localization of the head relative to the sensor array. Since the sensors in on-scalp MEG are positioned on the scalp, locations of the individual sensors depend on the subject\u27s head shape and size. The positions and orientations of on-scalp sensors must therefore be measured a every recording. This can be achieved by inverting conventional head localization, localizing the sensors relative to the head - rather than the other way around. In this study we present a practical method for localizing sensors using magnetic dipole-like coils attached to the subject\u27s head. We implement and evaluate the method in a set of on-scalp MEG recordings using a 7-channel on-scalp MEG system based on high critical temperature superconducting quantum interference devices (high-T-c SQUIDs). The method allows individually localizing the sensor positions, orientations, and responsivities with high accuracy using only a short averaging time (<= 2 mm, < 3 degrees and < 3%, respectively, with 1-s averaging), enabling continuous sensor localization. Calibrating and jointly localizing the sensor array can further improve the accuracy of position and orientation (< 1 mm and < 1 degrees, respectively, with 1-s coil recordings). We demonstrate source localization of on-scalp recorded somatosensory evoked activity based on coregistration with our method. Equivalent current dipole fits of the evoked responses corresponded well (within 4.2 mm) with those based on a commercial, whole-head MEG system

    High-density diffuse optical tomography for imaging human brain function

    Get PDF
    This review describes the unique opportunities and challenges for noninvasive optical mapping of human brain function. Diffuse optical methods offer safe, portable, and radiation free alternatives to traditional technologies like positron emission tomography or functional magnetic resonance imaging (fMRI). Recent developments in high-density diffuse optical tomography (HD-DOT) have demonstrated capabilities for mapping human cortical brain function over an extended field of view with image quality approaching that of fMRI. In this review, we cover fundamental principles of the diffusion of near infrared light in biological tissue. We discuss the challenges involved in the HD-DOT system design and implementation that must be overcome to acquire the signal-to-noise necessary to measure and locate brain function at the depth of the cortex. We discuss strategies for validation of the sensitivity, specificity, and reliability of HD-DOT acquired maps of cortical brain function. We then provide a brief overview of some clinical applications of HD-DOT. Though diffuse optical measurements of neurophysiology have existed for several decades, tremendous opportunity remains to advance optical imaging of brain function to address a crucial niche in basic and clinical neuroscience: that of bedside and minimally constrained high fidelity imaging of brain function

    Evaluating devices for the measurement of auditory-evoked fetal movement

    Get PDF
    Determining normal and abnormal fetal function in utero in order to better predict which fetuses are at risk for adverse outcome is critical. However, the medical imaging tools that could assist with diagnosis are very expensive and rarely available in the developing world. In this study, we developed a prototype audio-motio-tachograph (AMTG), which measures fetal movements through the recording of abdominal wall deformations and tested it in Rwanda. First, we showed that AMTG detected fetal signals and that fetuses respond to complex acoustic stimuli. In order to improve the sensitivity of the device, we then measured whole abdominal wall deformations in an automated way using a lab-based 3D optical measurement system, in which fringes are projected and the deflections recorded with a camera. We found that abdominal wall deformations can be measured accurately with a non-invasive measurement apparatus. Overall, we conclude that wearable modalities provide a promising alternative assessment capacity in fetal research, especially in low income countries

    On-scalp MEG using high-Tc SQUIDs: Measuring brain activity with superconducting magnetometers

    Get PDF
    This thesis describes work done towards realizing on-scalp magnetoencephalography (MEG) based on high critical temperature (high-Tc) superconducting quantum interference device (SQUID) sensors. MEG is a non-invasive neuroimaging modality that records the magnetic fields produced by neural currents with good spatial and high temporal resolution. However, state-of-the-art MEG is limited by the use of liquid helium-cooled sensors (T ~ 4 K). The amount of thermal insulation between the sensors and the subject\u27s head that is required to achieve the extreme temperature difference (~300 K), typically realized in the form of superinsulation foil and ~2 centimeters of vacuum, limits measurable signals. Replacing the sensors with high-Tc SQUIDs can mitigate this problem. High-Tc SQUIDs operate at much higher temperatures (90 K) allowing significant reduction of the stand-off distance (to ~1 mm). They can furthermore be cooled with liquid nitrogen (77 K), a cheaper, more sustainable alternative to the liquid helium used for cooling in conventional MEG systems.The work described in this thesis can be divided into three main areas: (I) simulation work for practical implementations of on-scalp systems, (II) development of a 7-channel high-Tc SQUID-based on-scalp MEG system, and (III) on-scalp MEG recordings.In the first part, spatial information density (SID), a metric to evaluate the performance of simulated MEG sensor arrays, is introduced and - along with total information capacity - used to compare the performance of various simulated full-head on-scalp MEG sensor arrays.\ua0Simulations demonstrate the potential of on-scalp MEG, with all on-scalp systems exhibiting higher information capacity than the state-of-the-art. SID further reveals more homogeneous sampling of the brain with flexible systems. A method for localizing magnetometers in on-scalp MEG systems is introduced and tested in simulations. The method uses small, magnetic dipole-like coils to determine the location and orientation of individual sensors, enabling straightforward co-registration in flexible on-scalp MEG systems. The effects of different uncertainties and errors on the accuracy of the method were quantified.In the second part, design, construction, and performance of a 7-channel on-scalp MEG system is described. The system houses seven densely-packed (2 mm edge-to-edge), head-aligned high-Tc SQUID magnetometers (9.2 mm x 8.6 mm) inside a single, liquid nitrogen-cooled cryostat. With a single filling, the system can be utilized for MEG recordings for >16 h with low noise levels (~0-130 fT). Using synchronized clocks and a direct injection feedback scheme, the system achieves low sensor crosstalk (<0.6%).\ua0In the third part, on-scalp MEG recordings with the 7-channel system as well as its predecessor, a single-channel system, are presented. The recordings are divided into proof-of-principle and benchmarking experiments. The former consist of well-studied, simple paradigms such as auditory evoked activity and visual alpha. Expected signal components were clearly seen in the on-scalp recordings. The benchmarking studies were done to compare and contrast on-scalp with state-of-the-art MEG. To this end, a number of experimental stimulus paradigms were recorded on human subjects with the high-Tc SQUID-based on-scalp systems as well as a state-of-the-art, commercial full-head MEG system. Results include the expected signal gains that are associated with recording on-scalp as well as new details of the neurophysiological signals. Using the previously described on-scalp MEG co-registration method enabled source localization with high agreement to the full-head recording (the distance between dipoles localized with the two systems was 4.2 mm)

    Development of a portable multi-channel broadband near infrared spectroscopy instrument to measure brain tissue oxygenation and metabolism during functional activation and seizures

    Get PDF
    Epilepsy is a common neurological disorder often developed during childhood, characterised by abnormal neuronal discharges. These spontaneous recurrent seizures can be associated with poor long-term neurological development. Near-infrared spectroscopy (NIRS) is a non-invasive tech- nique able to monitor cerebral concentration changes in oxygenated- (∆[HbO2]) and deoxygenated- (∆[HHb]) haemoglobin. However, current commercial NIRS systems use only a few wavelengths, limiting their use to haemodynamic monitoring. Broadband NIRS (bNIRS) systems use a larger number of wavelengths enabling changes in concentration of the oxidation state of cytochrome-c- oxidase (∆[oxCCO]) to be determined, a marker of cellular metabolism. This thesis describes the development and miniaturisation of an existing bNIRS system to monitor haemodynamic and metabolic changes in children with epilepsy. Using the latest technological advancements, the bulk and complexity of the system was reduced while increasing the number of measurement channels. Two miniature tungsten halogen light sources were utilised with time- multiplexing capabilities implemented (0.5Hz). Bifurcated optical fibre bundles (2.8mm diameter) connected to each light source and twelve detector fibre bundles (1mm diameter) arranged linearly into a ferrule (25mm diameter); modification of the interface between the detectors and lens-based spectrograph ensured compatibility with the increased detector number. Light was collimated to a diffraction grating with a wider 308nm bandwidth and the largest CCD image sensor available (1340x1300 array, 26.8x26mm) was integrated into the system. LabVIEW software was updated to enable simultaneous, real-time collection and display of intensity and concentration changes. Extensive testing of the system was performed; in-vivo testing in healthy adults using a Stroop task demonstrated a typical haemodynamic response with regional variation in metabolism. Si- multaneous bNIRS and electroencephalography data were collected from 12 children with epilepsy in the Neurology Unit. One patient case study is presented in detail, with temporal data from 17 seizures collected. A large decrease in metabolism was observed in the left posterior region, corresponding to a region of cortical malformation, suggesting an energetic deficiency in this re- gion. This indicates the potential for ∆[oxCCO] as an investigative marker in monitoring seizures, providing localised information about cellular oxygen utilisation

    Development of A Versatile Multichannel CWNIRS Instrument for Optical Brain-Computer Interface Applications

    Get PDF
    This thesis describes the design, development, and implementation of a versatile multichannel continuous-wave near-infrared spectroscopy (CWNIRS) instrument for brain-computer interface (BCI) applications. Specifically, it was of interest to assess what gains could be achieved by using a multichannel device compared to the single channel device implemented by Coyle in 2004. Moreover, the multichannel approach allows for the assessment of localisation of functional tasks in the cerebral cortex, and can identify lateralisation of haemodynamic responses to motor events. The approach taken to extend single channel to multichannel was based on a software-controlled interface. This interface allowed flexibility in the control of individual optodes including their synchronisation and modulation (AM, TDM, CDMA). Furthermore, an LED driver was developed for custom-made triple-wavelength LEDs. The system was commissioned using a series of experiments to verify the performance of individual components in the system. The system was then used to carry out a set of functional studies including motor imagery and cognitive tasks. The experimental protocols based on motor imagery and overt motor tasks were verified by comparison with fMRI. The multichannel approach identified stroke rehabilitation as a new application area for optical BCI. In addition, concentration changes in deoxyhaemoglobin were identified as being a more localised indicator of functional activity, which is important for effective BCI design. An assessment was made on the effect of the duration of the stimulus period on the haemodynamic signals. This demonstrated the possible benefits of using a shorter stimulus period to reduce the adverse affects of low blood pressure oscillations. i

    Development of A Versatile Multichannel CWNIRS Instrument for Optical Brain-Computer Interface Applications

    Get PDF
    This thesis describes the design, development, and implementation of a versatile multichannel continuous-wave near-infrared spectroscopy (CWNIRS) instrument for brain-computer interface (BCI) applications. Specifically, it was of interest to assess what gains could be achieved by using a multichannel device compared to the single channel device implemented by Coyle in 2004. Moreover, the multichannel approach allows for the assessment of localisation of functional tasks in the cerebral cortex, and can identify lateralisation of haemodynamic responses to motor events. The approach taken to extend single channel to multichannel was based on a software-controlled interface. This interface allowed flexibility in the control of individual optodes including their synchronisation and modulation (AM, TDM, CDMA). Furthermore, an LED driver was developed for custom-made triple-wavelength LEDs. The system was commissioned using a series of experiments to verify the performance of individual components in the system. The system was then used to carry out a set of functional studies including motor imagery and cognitive tasks. The experimental protocols based on motor imagery and overt motor tasks were verified by comparison with fMRI. The multichannel approach identified stroke rehabilitation as a new application area for optical BCI. In addition, concentration changes in deoxyhaemoglobin were identified as being a more localised indicator of functional activity, which is important for effective BCI design. An assessment was made on the effect of the duration of the stimulus period on the haemodynamic signals. This demonstrated the possible benefits of using a shorter stimulus period to reduce the adverse affects of low blood pressure oscillations. i

    Design of a wearable sensor system for neonatal seizure monitoring

    Get PDF

    Design of a wearable sensor system for neonatal seizure monitoring

    Get PDF
    corecore