1,595 research outputs found

    Stresses in the vicinity of an un-reinforced mitre intersection: an experimental and finite element comparison

    Get PDF
    The experimental investigation reported provides elastic stresses in the vicinity of the unreinforced intersection of a single 90° mitred bend, subjected to an in-plane bending moment. The specimen was extensively strain gauged on the outer surface. A small number of rosettes were also laid on the inside surface close to the welded intersection. The procedures used for the successful installation of the inside surface gauges are discussed. In the experiment, consideration was also given to deflections and rotations. Satisfactory comparisons with adaptive-p thin-shell finite element results were obtained in general and differences are explained in terms of the known experimental variables and finite element approximations. The nature of the stresses at such intersections is discussed and various methods of obtaining fatigue 'hot-spot' stresses are considered

    A mechanics-based model for simulation and control of flexible needle insertion in soft tissue

    Full text link
    AbstractIn needle-based medical procedures, beveled-tip exible needles are steered inside soft tissue with the aim of reaching pre-dened target locations. The efciency of needle-based interventions depends on accurate control of the needle tip. This paper presents a comprehensive mechanics-based model for simulation of planar needle insertion in soft tissue. The proposed model for needle deection is based on beam theory, works in real-time, and accepts the insertion velocity as an input that can later be used as a control command for needle steering. The model takes into account the effects of tissue deformation, needle-tissue friction, tissue cutting force, and needle bevel angle on needle deection. Using a robot that inserts a exible needle into a phantom tissue, various experiments are conducted to separately identify different subsets of the model parameters. The validity of the proposed model is veried by comparing the simulation results to the empirical data. The results demonstrate the accuracy of the proposed model in predicting the needle tip deection for different insertion velocities. I

    下腹部を対象とした極細針によるCTガイド下高正確度穿刺プランニング

    Get PDF
    早大学位記番号:新8149早稲田大

    Optohydrodynamics of soft fluid interfaces : Optical and viscous nonlinear effects

    Full text link
    Recent experimental developments showed that the use of the radiation pressure, induced by a continuous laser wave, to control fluid-fluid interface deformations at the microscale, represents a very promising alternative to electric or magnetic actuation. In this article, we solve numerically the dynamics and steady state of the fluid interface under the effects of buoyancy, capillarity, optical radiation pressure and viscous stress. A precise quantitative validation is shown by comparison with experimental data. New results due to the nonlinear dependence of the optical pressure on the angle of incidence are presented, showing different morphologies of the deformed interface going from needle-like to finger-like shapes, depending on the refractive index contrast. In the transient regime, we show that the viscosity ratio influences the time taken for the deformation to reach steady state

    Development of an online progressive mathematical model of needle deflection for application to robotic-assisted percutaneous interventions

    Get PDF
    A highly flexible multipart needle is under development in the Mechatronics in Medicine Laboratory at Imperial College, with the aim to achieve multi-curvature trajectories inside biological soft tissue, such as to avoid obstacles during surgery. Currently, there is no dedicated software or analytical methodology for the analysis of the needle’s behaviour during the insertion process, which is instead described empirically on the basis of experimental trials on synthetic tissue phantoms. This analysis is crucial for needle and insertion trajectory design purposes. It is proposed that a real-time, progressive, mathematical model of the needle deflection during insertion be developed. This model can serve three purposes, namely, offline needle and trajectory design in a forward solution of the model, when the loads acting on needle from the substrate are known; online, real-time identification of the loads that act on the needle in a reverse solution, when the deflections at discrete points along the needle length are known; and the development of a sensitivity matrix, which enables the calculation of the corrective loads that are required to drive the needle back on track, if any deviations occur away from a predefined trajectory. Previously developed mathematical models of needle deflection inside soft tissue are limited to small deflection and linear strain. In some cases, identical tip path and body shape after full insertion of the needle are assumed. Also, the axial load acting on the needle is either ignored or is calculated from empirical formulae, while its inclusion would render the model nonlinear even for small deflection cases. These nonlinearities are a result of the effects of the axial and transverse forces at the tip being co-dependent, restricting the calculation of the independent effects of each on the needle’s deflection. As such, a model with small deflection assumptions incorporating tip axial forces can be called “quasi-nonlinear” and a methodology is proposed here to tackle the identification of such axial force in the linear range. During large deflection of the needle, discrepancies between the shape of the needle after the insertion and its tip path, computed during the insertion, also significantly increase, causing errors in a model based on the assumption that they are the same. Some of the models developed to date have also been dependent on existing or experimentally derived material models of soft tissue developed offline, which is inefficient for surgical applications, where the biological soft tissue can change radically and experimentation on the patient is limited. Conversely, a model is proposed in this thesis which, when solved inversely, provides an estimate for the contact stiffness of the substrate in a real-time manner. The study and the proposed model and techniques involved are limited to two dimensional projections of the needle movements, but can be easily extended to the 3-dimensional case. Results which demonstrate the accuracy and validity of the models developed are provided on the basis of simulations and via experimental trials of a multi-part 2D steering needle in gelatine.Open Acces

    A Framework for Tumor Localization in Robot-Assisted Minimally Invasive Surgery

    Get PDF
    Manual palpation of tissue is frequently used in open surgery, e.g., for localization of tumors and buried vessels and for tissue characterization. The overall objective of this work is to explore how tissue palpation can be performed in Robot-Assisted Minimally Invasive Surgery (RAMIS) using laparoscopic instruments conventionally used in RAMIS. This thesis presents a framework where a surgical tool is moved teleoperatively in a manner analogous to the repetitive pressing motion of a finger during manual palpation. We interpret the changes in parameters due to this motion such as the applied force and the resulting indentation depth to accurately determine the variation in tissue stiffness. This approach requires the sensorization of the laparoscopic tool for force sensing. In our work, we have used a da Vinci needle driver which has been sensorized in our lab at CSTAR for force sensing using Fiber Bragg Grating (FBG). A computer vision algorithm has been developed for 3D surgical tool-tip tracking using the da Vinci \u27s stereo endoscope. This enables us to measure changes in surface indentation resulting from pressing the needle driver on the tissue. The proposed palpation framework is based on the hypothesis that the indentation depth is inversely proportional to the tissue stiffness when a constant pressing force is applied. This was validated in a telemanipulated setup using the da Vinci surgical system with a phantom in which artificial tumors were embedded to represent areas of different stiffnesses. The region with high stiffness representing tumor and region with low stiffness representing healthy tissue showed an average indentation depth change of 5.19 mm and 10.09 mm respectively while maintaining a maximum force of 8N during robot-assisted palpation. These indentation depth variations were then distinguished using the k-means clustering algorithm to classify groups of low and high stiffnesses. The results were presented in a colour-coded map. The unique feature of this framework is its use of a conventional laparoscopic tool and minimal re-design of the existing da Vinci surgical setup. Additional work includes a vision-based algorithm for tracking the motion of the tissue surface such as that of the lung resulting from respiratory and cardiac motion. The extracted motion information was analyzed to characterize the lung tissue stiffness based on the lateral strain variations as the surface inflates and deflates

    Pilot dynamic response to sudden flight control system failures and implications for design

    Get PDF
    Pilot dynamic response to sudden flight control system failure

    Shape Memory Alloy Actuators and Sensors for Applications in Minimally Invasive Interventions

    Get PDF
    Reduced access size in minimally invasive surgery and therapy (MIST) poses several restriction on the design of the dexterous robotic instruments. The instruments should be developed that are slender enough to pass through the small sized incisions and able to effectively operate in a compact workspace. Most existing robotic instruments are operated by big actuators, located outside the patient’s body, that transfer forces to the end effector via cables or magnetically controlled actuation mechanism. These instruments are certainly far from optimal in terms of their cost and the space they require in operating room. The lack of adequate sensing technologies make it very challenging to measure bending of the flexible instruments, and to measure tool-tissue contact forces of the both flexible and rigid instruments during MIST. Therefore, it requires the development of the cost effective miniature actuators and strain/force sensors. Having several unique features such as bio-compatibility, low cost, light weight, large actuation forces and electrical resistivity variations, the shape memory alloys (SMAs) show promising applications both as the actuators and strain sensors in MIST. However, highly nonlinear hysteretic behavior of the SMAs hinders their use as actuators. To overcome this problem, an adaptive artificial neural network (ANN) based Preisach model and a model predictive controller have been developed in this thesis to precisely control the output of the SMA actuators. A novel ultra thin strain sensor is also designed using a superelastic SMA wire, which can be used to measure strain and forces for many surgical and intervention instruments. A da Vinci surgical instrument is sensorized with these sensors in order to validate their force sensing capability
    corecore