3,579 research outputs found
Recommended from our members
iSEA: IoT-based smartphone energy assistant for prompting energy-aware behaviors in commercial buildings
Providing personalized energy-use information to individual occupants enables the adoption of energy-aware behaviors in commercial buildings. However, the implementation of individualized feedback still remains challenging due to the difficulties in collecting personalized data, tracking personal behaviors, and delivering personalized tailored information to individual occupants. Nowadays, the Internet of Things (IoT) technologies are used in a variety of applications including real-time monitoring, control, and decision-making due to the flexibility of these technologies for fusing different data streams. In this paper, we propose a novel IoT-based smartphone energy assistant (iSEA) framework which prompts energy-aware behaviors in commercial buildings. iSEA tracks individual occupants through tracking their smartphones, uses a deep learning approach to identify their energy usage, and delivers personalized tailored feedback to impact their usage. iSEA particularly uses an energy-use efficiency index (EEI) to understand behaviors and categorize them into efficient and inefficient behaviors. The iSEA architecture includes four layers: physical, cloud, service, and communication. The results of implementing iSEA in a commercial building with ten occupants over a twelve-week duration demonstrate the validity of this approach in enhancing individualized energy-use behaviors. An average of 34% energy savings was measured by tracking occupants’ EEI by the end of the experimental period. In addition, the results demonstrate that commercial building occupants often ignore controlling over lighting systems at their departure events that leads to wasting energy during non-working hours. By utilizing the existing IoT devices in commercial buildings, iSEA significantly contributes to support research efforts into sensing and enhancing energy-aware behaviors at minimal costs
Recommended from our members
Optimizing Radiant Systems for Energy Efficiency and Comfort
Radiant cooling and heating systems provide an opportunity to achieve significant energy savings, peak demand reduction, load shifting, and thermal comfort improvements compared to conventional all-air systems. As a result, application of these systems has increased in recent years, particularly in zero-net-energy (ZNE) and other advanced low-energy buildings. Despite this growth, completed installations to date have demonstrated that controls and operation of radiant systems can be challenging due to a lack of familiarity within the heating, ventilation, and air-conditioning (HVAC) design and operations professions, often involving new concepts (particularly related to the slow response in high thermal mass radiant systems). To achieve the significant reductions in building energy use proposed by California Public Utilities Commission’s (CPUC’s) Energy Efficiency Strategic Plan that all new non-residential buildings be ZNE by 2030, it is critical that new technologies that will play a major role in reaching this goal be applied in an effective manner. This final report describes the results of a comprehensive multi-faceted research project that was undertaken to address these needed enhancements to radiant technology by developing the following: (1) sizing and operation tools (currently unavailable on the market) to provide reliable methods to take full advantage of the radiant systems to provide improved energy performance while maintaining comfortable conditions, (2) energy, cost, and occupant comfort data to provide real world examples of energy efficient, affordable, and comfortable buildings using radiant systems, and (3) Title-24 and ASHRAE Standards advancements to enhance the building industry’s ability to achieve significant energy efficiency goals in California with radiant systems. The research team used a combination of full-scale fundamental laboratory experiments, whole-building energy simulations and simplified tool development, and detailed field studies and control demonstrations to assemble the new information, guidance and tools necessary to help the building industry achieve significant energy efficiency goals for radiant systems in California
Recommended from our members
Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings
Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions
Recommended from our members
State-of-the-art on research and applications of machine learning in the building life cycle
Fueled by big data, powerful and affordable computing resources, and advanced algorithms, machine learning has been explored and applied to buildings research for the past decades and has demonstrated its potential to enhance building performance. This study systematically surveyed how machine learning has been applied at different stages of building life cycle. By conducting a literature search on the Web of Knowledge platform, we found 9579 papers in this field and selected 153 papers for an in-depth review. The number of published papers is increasing year by year, with a focus on building design, operation, and control. However, no study was found using machine learning in building commissioning. There are successful pilot studies on fault detection and diagnosis of HVAC equipment and systems, load prediction, energy baseline estimate, load shape clustering, occupancy prediction, and learning occupant behaviors and energy use patterns. None of the existing studies were adopted broadly by the building industry, due to common challenges including (1) lack of large scale labeled data to train and validate the model, (2) lack of model transferability, which limits a model trained with one data-rich building to be used in another building with limited data, (3) lack of strong justification of costs and benefits of deploying machine learning, and (4) the performance might not be reliable and robust for the stated goals, as the method might work for some buildings but could not be generalized to others. Findings from the study can inform future machine learning research to improve occupant comfort, energy efficiency, demand flexibility, and resilience of buildings, as well as to inspire young researchers in the field to explore multidisciplinary approaches that integrate building science, computing science, data science, and social science
Recommended from our members
Integrating Smart Ceiling Fans and Communicating Thermostats to Provide Energy-Efficient Comfort
The project goal was to identify and test the integration of smart ceiling fans and communicating thermostats. These highly efficient ceiling fans use as much power as an LED light bulb and have onboard temperature and occupancy sensors for automatic operationbased on space conditions. The Center for the Environment (CBE) at UC Berkeley led the research team including TRC, Association for Energy Affordability (AEA), and Big Ass Fans (BAF). The research team conducted laboratory tests, installed99 ceiling fans and 12 thermostats in four affordable multifamily housing sites in California’s Central Valley, interviewed stakeholders to develop a case study, developed an online design tool and design guide, outlined codes and standards outreach, and published several papers.The project team raised indoor cooling temperature setpoints and used ceiling fans as the first stage of cooling; this sequencing of ceiling fans and air conditioningreducesenergy consumption, especially during peak periods, while providing thermal comfort.The field demonstration resulted in 39% measured compressor energy savings during the April–October cooling seasoncompared to baseline conditions, normalized for floor area. Weather-normalized energy use varied from a 36% increase to 71% savings, withmedian savings of 15%.This variability reflects the diversity in buildings, mechanical systems, prior operation settings, space types, andoccupants’ schedules,preferences, and motivations. All commercial spaces with regular occupancy schedules (and twoof the irregularly-occupied commercial spaces and one of the homes) showed energy savings on an absolute basis before normalizing for warmer intervention temperatures,and 10 of 13 sites showed energy savings on a weather-normalized basis. The ceiling fans provided cooling for one site for months during hot weather when the coolingequipment failed.Occupants reported high satisfaction with the ceiling fans and improved thermal comfort. This technology can apply to new and retrofit residential and commercial buildings
Recommended from our members
Advances to ASHRAE Standard 55 to encourage more effective building practice
ASHRAE Standard 55 has been evolving in recent years to encourage more sustainable building designs and operational practices. A series of changes address issues for which past design practice has been deficient or overly constrained. Some of the changes were enabled by findings from field studies of comfort and energy-efficiency, and others by new developments in the design- and building-management professions. The changes have been influencing practice and spurring follow-on research.The Standard now addresses effects of elevated air movement, solar gain on the occupant, and draft at the ankles, each with several impacts on energy-efficient design and operation. It also addresses the most important source of discomfort in modern buildings, the large inter- and intra-personal variability in thermal comfort requirements, by classifying the occupants’ personal control and adaptive options in a form that can be used in building rating systems. In order to facilitate design, new computer tools extend the use of the standard toward direct use in designers’ workflow. The standard also includes provisions for monitoring and evaluating buildings in operation. This paper summarizes these developments and their underlying research, and attempts to look ahead
Recommended from our members
High-Performance Integrated Window and Façade Solutions for California
The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California
Recommended from our members
System-level key performance indicators for building performance evaluation
Quantifying building energy performance through the development and use of key performance indicators (KPIs) is an essential step in achieving energy saving goals in both new and existing buildings. Current methods used to evaluate improvements, however, are not well represented at the system-level (e.g., lighting, plug-loads, HVAC, service water heating). Instead, they are typically only either measured at the whole building level (e.g., energy use intensity) or at the equipment level (e.g., chiller efficiency coefficient of performance (COP)) with limited insights for benchmarking and diagnosing deviations in performance of aggregated equipment that delivers a specific service to a building (e.g., space heating, lighting). The increasing installation of sensors and meters in buildings makes the evaluation of building performance at the system level more feasible through improved data collection. Leveraging this opportunity, this study introduces a set of system-level KPIs, which cover four major end-use systems in buildings: lighting, MELs (Miscellaneous Electric Loads, aka plug loads), HVAC (heating, ventilation, and air-conditioning), and SWH (service water heating), and their eleven subsystems. The system KPIs are formulated in a new context to represent various types of performance, including energy use, peak demand, load shape, occupant thermal comfort and visual comfort, ventilation, and water use. This paper also presents a database of system KPIs using the EnergyPlus simulation results of 16 USDOE prototype commercial building models across four vintages and five climate zones. These system KPIs, although originally developed for office buildings, can be applied to other building types with some adjustment or extension. Potential applications of system KPIs for system performance benchmarking and diagnostics, code compliance, and measurement and verification are discussed
- …