3,690 research outputs found
Recommended from our members
Fully automated convolutional neural network-based affine algorithm improves liver registration and lesion co-localization on hepatobiliary phase T1-weighted MR images.
BackgroundLiver alignment between series/exams is challenged by dynamic morphology or variability in patient positioning or motion. Image registration can improve image interpretation and lesion co-localization. We assessed the performance of a convolutional neural network algorithm to register cross-sectional liver imaging series and compared its performance to manual image registration.MethodsThree hundred fourteen patients, including internal and external datasets, who underwent gadoxetate disodium-enhanced magnetic resonance imaging for clinical care from 2011 to 2018, were retrospectively selected. Automated registration was applied to all 2,663 within-patient series pairs derived from these datasets. Additionally, 100 within-patient series pairs from the internal dataset were independently manually registered by expert readers. Liver overlap, image correlation, and intra-observation distances for manual versus automated registrations were compared using paired t tests. Influence of patient demographics, imaging characteristics, and liver uptake function was evaluated using univariate and multivariate mixed models.ResultsCompared to the manual, automated registration produced significantly lower intra-observation distance (p < 0.001) and higher liver overlap and image correlation (p < 0.001). Intra-exam automated registration achieved 0.88 mean liver overlap and 0.44 mean image correlation for the internal dataset and 0.91 and 0.41, respectively, for the external dataset. For inter-exam registration, mean overlap was 0.81 and image correlation 0.41. Older age, female sex, greater inter-series time interval, differing uptake, and greater voxel size differences independently reduced automated registration performance (p ≤ 0.020).ConclusionA fully automated algorithm accurately registered the liver within and between examinations, yielding better liver and focal observation co-localization compared to manual registration
GIST: an interactive, GPU-based level set segmentation tool for 3D medical images
technical reportWhile level sets have demonstrated a great potential for 3D medical image segmentation, their usefulness has been limited by two problems. First, 3D level sets are relatively slow to compute. Second, their formulation usually entails several free parameters which can be very difficult to correctly tune for specific applications. The second problem is compounded by the first. This paper describes a new tool for 3D segmentation that addresses these problems by computing level-set surface models at interactive rates. This tool employs two important, novel technologies. First is the mapping of a 3D level-set solver onto a commodity graphics card (GPU). This mapping relies on a novel mechanism for GPU memory management. The interactive rates level-set PDE solver give the user immediate feedback on the parameter settings, and thus users can tune free parameters and control the shape of the model in real time. The second technology is the use of region-based speed functions, which allow a user to quickly and intuitively specify the behavior of the deformable model. We have found that the combination of these interactive tools enables users to produce good, reliable segmentations. To support this observation, this paper presents qualitative results from several different datasets as well as a quantitative evaluation from a study of brain tumor segmentations
Calipso: Physics-based Image and Video Editing through CAD Model Proxies
We present Calipso, an interactive method for editing images and videos in a
physically-coherent manner. Our main idea is to realize physics-based
manipulations by running a full physics simulation on proxy geometries given by
non-rigidly aligned CAD models. Running these simulations allows us to apply
new, unseen forces to move or deform selected objects, change physical
parameters such as mass or elasticity, or even add entire new objects that
interact with the rest of the underlying scene. In Calipso, the user makes
edits directly in 3D; these edits are processed by the simulation and then
transfered to the target 2D content using shape-to-image correspondences in a
photo-realistic rendering process. To align the CAD models, we introduce an
efficient CAD-to-image alignment procedure that jointly minimizes for rigid and
non-rigid alignment while preserving the high-level structure of the input
shape. Moreover, the user can choose to exploit image flow to estimate scene
motion, producing coherent physical behavior with ambient dynamics. We
demonstrate Calipso's physics-based editing on a wide range of examples
producing myriad physical behavior while preserving geometric and visual
consistency.Comment: 11 page
Computer Tomography 3D Edge Detection Comparative for Metrology Applications
AbstractThe CT process for metrology applications is very complex because has many factors that influence the loss of accuracy during CT measurements. One of the most critical is the edge detection also called surface extraction or image segmentation, which is the process of surface formation from the CT‘s volume data that represents a grey value corresponding to the mass attenuation coefficient of the object material. This paper presents different edge detection methods commonly used in areas like machine and computer vision and they are analyzed as an alternative to the common methods used in CT for metrology applications. Each method is described and analyzed separately in order to highlight its advantages and disadvantages from a metrological point of view. An experimental comparative between two of them is also shown
Mesh-to-raster based non-rigid registration of multi-modal images
Region of interest (ROI) alignment in medical images plays a crucial role in
diagnostics, procedure planning, treatment, and follow-up. Frequently, a model
is represented as triangulated mesh while the patient data is provided from CAT
scanners as pixel or voxel data. Previously, we presented a 2D method for
curve-to-pixel registration. This paper contributes (i) a general
mesh-to-raster (M2R) framework to register ROIs in multi-modal images; (ii) a
3D surface-to-voxel application, and (iii) a comprehensive quantitative
evaluation in 2D using ground truth provided by the simultaneous truth and
performance level estimation (STAPLE) method. The registration is formulated as
a minimization problem where the objective consists of a data term, which
involves the signed distance function of the ROI from the reference image, and
a higher order elastic regularizer for the deformation. The evaluation is based
on quantitative light-induced fluoroscopy (QLF) and digital photography (DP) of
decalcified teeth. STAPLE is computed on 150 image pairs from 32 subjects, each
showing one corresponding tooth in both modalities. The ROI in each image is
manually marked by three experts (900 curves in total). In the QLF-DP setting,
our approach significantly outperforms the mutual information-based
registration algorithm implemented with the Insight Segmentation and
Registration Toolkit (ITK) and Elastix
- …