    Collaborative Processing of Wearable and Ambient Sensor System for Blood Pressure Monitoring

    Get PDF
    This paper describes wireless wearable and ambient sensors that cooperate to monitor a person’s vital signs such as heart rate and blood pressure during daily activities. Each wearable sensor is attached on different parts of the body. The wearable sensors require a high sampling rate and time synchronization to provide a precise analysis of the received signals. The trigger signal for synchronization is provided by the ambient sensors, which detect the user’s presence. The Bluetooth and IEEE 802.15.4 wireless technologies are used for real-time sensing and time synchronization. Thus, this wearable health-monitoring sensor response is closely related to the context in which it is being used. Experimental results indicate that the system simultaneously provides information about the user’s location and vital signs, and the synchronized wearable sensors successfully measures vital signs with a 1 ms resolution

    A comprehensive survey of wireless body area networks on PHY, MAC, and network layers solutions

    Get PDF
    Recent advances in microelectronics and integrated circuits, system-on-chip design, wireless communication and intelligent low-power sensors have allowed the realization of a Wireless Body Area Network (WBAN). A WBAN is a collection of low-power, miniaturized, invasive/non-invasive lightweight wireless sensor nodes that monitor the human body functions and the surrounding environment. In addition, it supports a number of innovative and interesting applications such as ubiquitous healthcare, entertainment, interactive gaming, and military applications. In this paper, the fundamental mechanisms of WBAN including architecture and topology, wireless implant communication, low-power Medium Access Control (MAC) and routing protocols are reviewed. A comprehensive study of the proposed technologies for WBAN at Physical (PHY), MAC, and Network layers is presented and many useful solutions are discussed for each layer. Finally, numerous WBAN applications are highlighted

    A Distributed Multiagent System Architecture for Body Area Networks Applied to Healthcare Monitoring

    Get PDF

    Energy Efficient Cooperative Communications for Wireless Body Area Networks

    Get PDF
    It is expected that Wireless Body Area Network (WBAN) will greatly improve the quality of our life because of its myriad applications for our human beings. However, one of the challenges is to design energy efficient communication protocols to support the reliable communication as well as to prolong the network lifetime. Cooperative communications have the advantage of spatial diversity to combat multipath fading, thus improving the link reliability and boosting energy efficiency. In this thesis, we investigate the energy efficient cooperative communications for WBAN. We first analyze the outage performance of three transmission schemes, namely direct transmission, single relay cooperation, and multi-relay cooperation. To minimize the energy consumption, we then study the problem of optimal power allocation with the constraint of targeted outage probability. Two strategies of power allocation are considered: power allocation with and without posture state information. Simulation results verify the accuracy of the analysis and demonstrate that: 1) power allocation making use of the posture information can reduce the energy consumption; 2) within a possible range of the channel quality in WBAN, cooperative communication is more energy efficient than direct transmission only when the path loss between the transmission pair is higher than a threshold; and 3) for most of the typical channel quality due to the fixed transceiver locations on human body, cooperative communication is effective in reducing energy consumption

    高信頼ミリ波帯 WBAN の研究

    Get PDF
    Tohoku University末松憲治課

    A comprehensive review of wireless body area network

    Get PDF
    Recent development and advancement of information and communication technologies facilitate people in different dimensions of life. Most importantly, in the healthcare industry, this has become more and more involved with the information and communication technology-based services. One of the most important services is monitoring of remote patients, that enables the healthcare providers to observe, diagnose and prescribe the patients without being physically present. The advantage of miniaturization of sensor technologies gives the flexibility of installing in, on or off the body of patients, which is capable of forwarding physiological data wirelessly to remote servers. Such technology is named as Wireless Body Area Network (WBAN). In this paper, WBAN architecture, communication technologies for WBAN, challenges and different aspects of WBAN are illustrated. This paper also describes the architectural limitations of existing WBAN communication frameworks. blueFurthermore, implementation requirements are presented based on IEEE 802.15.6 standard. Finally, as a source of motivation towards future development of research incorporating Software Defined Networking (SDN), Energy Harvesting (EH) and Blockchain technology into WBAN are also provided

    Experimental investigation into novel methods of reliable and secure on-body communications with low system overheads

    Get PDF
    Until recently the concept of wearable biosensors for purposes of medical monitoring was restricted to wired sensor applications. Recent advances in electronics and wireless communications have made the possibility of removing the wire from sensor applications a possibility. These advances have led to the development of small scale, wearable, sensing and communication platforms that can be placed on the human body creating the foundation for a Body Sensor Network (BSN). Body Sensor Networks aim to remove the restrictions that traditional wired sensors impose. The anticipation is that BSNs will permit the monitoring of physiological signals in any environment without limitation, giving Physicians the ability to monitor patients more closely and in environments that they cannot monitor today. Even with the recent advancements of electronics and wireless communications there are still many unanswered questions for practical solutions of BSNs that prevent BSNs from replacing traditional wired systems altogether. There is a great need for research into BSN architectures to set the standard for wireless sensor monitoring. In this work a development platform has been created for the investigation into the design and implementation of practical BSN solutions. The platform is used to compare BSN architectures and provide quantifiable results. From this work BSN architecture components that provide optimizations in system performance, energy, network lifetime and security are recommended. In Chapter 3 BSN network architectures employing the use of relaying of creeping waves is investigated. The investigation includes experimental analysis of various test environments. Experimentation demonstrates that the relaying of creeping waves offers considerable performance gains when compared to non-relay networks. For example, relaying is shown to increase network-lifetime by a factor of 13, decrease energy-per-bit requirements by 13 dB and provide the ability for the network to compensate for considerably wider fade margins. In Chapter 4 utilizing the randomness of the wireless channel for securing on-body communications with low overheads is considered. A low-complexity algorithm for establishing symmetric encryption keys is presented and validated. The algorithm relies on readily available RSSI measurements obtained from existing packets being sent and received in the network. The generated bit sequences from the algorithm are evaluated for matching between two communicating parties and mismatching with a malicious eavesdropper. It is shown that the algorithm produces long sequences of highly random bits that are perfectly matched between legitimate parties and highly mismatched with the eavesdropper

    Reliable and Energy Efficient Network Protocols for Wireless Body Area Networks

    Get PDF
    In a wireless Body Area Network (WBAN) various sensors are attached on clothing, on the body or are even implanted under the skin. The wireless nature of the network and the wide variety of sensors offers numerous new, practical and innovative applications. A motivating example can be found in the world of health monitoring. The sensors of the WBAN measure for example the heartbeat, the body temperature or record a prolonged electrocardiogram. Using a WBAN, the patient experiences a greater physical mobility and is no longer compelled to stay in a hospital. A WBAN imposes the networks some strict and specific requirements. The devices are tiny, leaving only limited space for a battery. It is therefore of uttermost importance to restrict the energy consumption in the network. A possible solution is the development of energy efficient protocols that regulate the communication between the radios. Further, it is also important to consider the reliability of the communication. The data sent contains medical information and one has to make sure that it is correctly received at the personal device. It is not allowed that a critical message gets lost. In addition, a WBAN has to support the heterogeneity of its devices. This thesis focuses on the development of energy efficient and reliable network protocols for WBANs. Considered solutions are the use of multi-hop communication and the improved interaction between the different network layers. Mechanisms to reduce the energy consumption and to grade up the reliability of the communication are presented. In a first step, the physical layer of the communication near the human body is studied and investigated. The probability of a connection between two nodes on the body is modeled and used to investigate which network topologies can be considered as the most energy efficient and reliable. Next, MOFBAN, a lightweight framework for network architecture is presented. Finally, CICADA is presented: a new cross layer protocol for WBANs that both handles channel medium access and routing

    A MAC protocol for quality of service provisioning in adaptive biomedical wireless sensor networks

    Get PDF
    Doctorate program on Electronics and Computer EngineeringNew healthcare solutions are being explored to improve the quality of care and the quality of life of patients, as well as the sustainability and efficiency of the healthcare services. In this context, wireless sensor networks (WSNs) constitute a key technology for closing the loop between patients and healthcare providers, as WSNs provide sensing ability, as well as mobility and portability, essential characteristics for wide acceptance of wireless healthcare technology. Despite the recent advances in the field, the wide adoption of healthcare WSNs is still conditioned by quality of service (QoS) issues, namely at the medium access control (MAC) level. MAC protocols currently available for WSNs are not able to provide the required QoS to healthcare applications in scenarios of medical emergency or intensive medical care. To cover this shortage, the present work introduces a MAC protocol with novel concepts to assure the required QoS regarding the data transmission robustness, packet delivery deadline, bandwidth efficiency, and energy preservation. The proposed MAC protocol provides a new and efficient dynamic reconfiguration mechanism, so that relevant operational parameters may be redefined dynamically in accordance with the patients’ clinical state. The protocol also provides a channel switching mechanism and the capacity of forwarding frames in two-tier network structures. To test the performance of the proposed MAC protocol and compare it with other MAC protocols, a simulation platform was implemented. In order to validate the simulation results, a physical testbed was implemented to replicate the tests and verify the results. Sensor nodes were specifically designed and assembled to implement this physical testbed. New healthcare solutions are being explored to improve the quality of care and the quality of life of patients, as well as the sustainability and efficiency of the healthcare services. In this context, wireless sensor networks (WSNs) constitute a key technology for closing the loop between patients and healthcare providers, as WSNs provide sensing ability, as well as mobility and portability, essential characteristics for wide acceptance of wireless healthcare technology. Despite the recent advances in the field, the wide adoption of healthcare WSNs is still conditioned by quality of service (QoS) issues, namely at the medium access control (MAC) level. MAC protocols currently available for WSNs are not able to provide the required QoS to healthcare applications in scenarios of medical emergency or intensive medical care. To cover this shortage, the present work introduces a MAC protocol with novel concepts to assure the required QoS regarding the data transmission robustness, packet delivery deadline, bandwidth efficiency, and energy preservation. The proposed MAC protocol provides a new and efficient dynamic reconfiguration mechanism, so that relevant operational parameters may be redefined dynamically in accordance with the patients’ clinical state. The protocol also provides a channel switching mechanism and the capacity of forwarding frames in two-tier network structures. To test the performance of the proposed MAC protocol and compare it with other MAC protocols, a simulation platform was implemented. In order to validate the simulation results, a physical testbed was implemented to replicate the tests and verify the results. Sensor nodes were specifically designed and assembled to implement this physical testbed. Preliminary tests using the simulation and physical platforms showed that simulation results diverge significantly from reality, if the performance of the WSN software components is not considered. Therefore, a parametric model was developed to reflect the impact of this aspect on a physical WSN. Simulation tests using the parametric model revealed that the results match satisfactorily those obtained in reality. After validating the simulation platform, comparative tests against IEEE 802.15.4, a prominent standard used in many wireless healthcare systems, showed that the proposed MAC protocol leads to a performance increase regarding diverse QoS metrics, such as packet loss and bandwidth efficiency, as well as scalability, adaptability, and power consumption. In this way, AR-MAC is a valuable contribution to the deployment of wireless e-health technology and related applications.Novas soluções de cuidados de saúde estão a ser exploradas para melhorar a qualidade de tratamento e a qualidade de vida dos pacientes, assim como a sustentabilidade e eficiência dos serviços de cuidado de saúde. Neste contexto, as redes de sensores sem fios (wireless sensor networks - WSN) são uma tecnologia chave para fecharem o ciclo entre os pacientes e os prestadores de cuidados de saúde, uma vez que as WSNs proporcionam não só capacidade sensorial mas também mobilidade e portabilidade, caracteristicas essenciais para a aceitação à larga escala da tecnologia dos cuidados de saúde sem fios. Apesar dos avanços recentes na área, a aceitação genérica das WSNs de cuidados de saúde ainda está condicionada por aspectos relacionados com a qualidade de serviço (quality of service - QoS), nomeadamente ao nível do controlo de acesso ao meio (medium access control - MAC). Os protocolos MAC actualmente disponíveis para WSNs são incapazes de fornecer a QoS desejada pelas aplicações médicas em cenários de emergência ou cuidados médicos intensivos. Para suprimir esta carência, o presente trabalho apresenta um protocolo MAC com novos conceitos a fim de assegurar a QoS respeitante à robustez de transmissão de dados, ao limite temporal da entrega de pacotes, à utilização da largura de banda e à preservação da energia eléctrica. O protocolo MAC proposto dispõe de um novo e eficiente mecanismo de reconfiguração para que os parâmetros operacionais relevantes possam ser redefinidos dinamicamente de acordo com o estado de saúde do paciente. O protocolo também oferece um mecanismo autónomo de comutação de canal, bem como a capacidade de encaminhar pacotes em redes de duas camadas. Para testar o desempenho do protocolo MAC proposto e compará-lo com outros protocolos MAC foi implementada uma plataforma de simulação. A fim de validar os resultados da simulação foi também implementada uma plataforma física para permitir replicar os testes e verificar os resultados. Esta plataforma física inclui nós sensoriais concebidos e construídos de raiz para o efeito. Testes preliminares usando as plataformas de simulação e física mostraram que os resultados de simulação divergem significativamente da realidade, caso o desempenho dos componentes do software presentes nos componentes da WSN não seja considerado. Por conseguinte, desenvolveu-se um modelo paramétrico para reflectir o impacto deste aspecto numa WSN real. Testes de simulação efectuados com o modelo paramétrico apresentaram resultados muito satisfatórios quando comparados com os obtidos na realidade. Uma vez validada a plataforma de simulação, efectuaram-se testes comparativos com a norma IEEE 802.15.4, proeminentemente usada em projectos académicos de cuidados de saúde sem fios. Os resultados mostraram que o protocolo MAC conduz a um desempenho superior no tocante a diversas métricas QoS, tais como perdas de pacotes e utilização de largura de banda, bem como no respeitante à escalabilidade, adaptabilidade e consumo de energia eléctrica. Assim sendo, o protocolo MAC proposto representa um valioso contributo para a concretização efectiva dos cuidados de saúde sem fios e suas aplicações

    Estudo e Desenvolvimento de Sistema para Monitorização de Sinais Vitais Sem Fios

    Get PDF
    Com o avanço tecnológico, tem-se vindo a verificar nas mais diversas áreas a interação entre equipamentos, denominada Internet of Things (IoT). Assim, é possível que os mais diversos equipamentos estejam a comunicar entre si, permitindo monitorizar diversas variáveis. Posto isto, estas inovações tecnológicas têm vindo, pouco a pouco a entrar na área da saúde. Cada vez mais as instituições de saúde procuraram estar na vanguarda, tornandose competitivas entre elas, o que resulta em melhor oferta para o utente. Assim, é comum que muitos dados sejam tratados já de forma digital, permitindo que, tanto o utente como o médico que o acompanha, tenham acesso aos dados a partir de qualquer dispositivo, evitando deslocações, muitas vezes dispendiosas, às instalações. Assim, ao longo deste documento foram abordados os diversos sistemas de saúde que existem, ou que se encontram em desenvolvimento, que envolvam tecnologia Wireless. Foi definido que seria importante desenvolver um sistema capaz de enviar dados de monitorização em tempo real para mais do que um dispositivo em simultâneo, pelo que, após pesquisa, se chegou às condições que o sistema deveria possuir para dar resposta, sobretudo, à frequência com que certos sinais vitais devem ser registados. Desenvolveu-se uma página Web que apresenta os mais variados sinais vitais, dando-se, também, início ao desenvolvimento do dispositivo que irá recolher todos esses sinais, começando pelo desenvolvimento do termómetro.With technological advances, the interaction between equipment, called Internet of Things (IoT), has been occurring in several areas. Thus, it is possible that the most varied equipment are communicating with each other, allowing the monitoring of several variables. That said, these technological innovations have been gradually entering the health area. More and more health institutions have sought to be at the forefront, becoming competitive among themselves, which results in a better offer for the user. Thus, it is common for much data to be processed digitally, allowing, both the user and the physician who accompanies, to access the data from any device, thus avoiding the often-costly trips to the health facilities. Thus, throughout this document the various health systems that exist, or are under development, that involve wireless technology have been discussed. It was defined that it would be important to develop a system capable of sending vital signs in real time to more than one device at the same time. So, after research, the conditions that the system should have to meet, especially, the frequency with which certain vital signs should be recorded were reached. A web page was developed that presents the most varied vital signs, and the development of the device that will collect all these signals began, starting with the development of the thermometer