18,964 research outputs found

    Ceramic regenerator systems development program

    Get PDF
    Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability test in Ford 707 industrial gas turbine engines. The results of 19,600 hours of turbine engine durability testing are described. Two materials, aluminum silicate and magnesium aluminum silicate, continue to show promise toward achieving the durability objectives of this program. A regenerator core made from aluminum silicate showed minimal evidence of chemical attack damage after 6935 hours of engine test at 800 C and another showed little distress after 3510 hours at 982 C. Results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included

    Programming MPSoC platforms: Road works ahead

    Get PDF
    This paper summarizes a special session on multicore/multi-processor system-on-chip (MPSoC) programming challenges. The current trend towards MPSoC platforms in most computing domains does not only mean a radical change in computer architecture. Even more important from a SW developer´s viewpoint, at the same time the classical sequential von Neumann programming model needs to be overcome. Efficient utilization of the MPSoC HW resources demands for radically new models and corresponding SW development tools, capable of exploiting the available parallelism and guaranteeing bug-free parallel SW. While several standards are established in the high-performance computing domain (e.g. OpenMP), it is clear that more innovations are required for successful\ud deployment of heterogeneous embedded MPSoC. On the other hand, at least for coming years, the freedom for disruptive programming technologies is limited by the huge amount of certified sequential code that demands for a more pragmatic, gradual tool and code replacement strategy

    Ceramic regenerator systems development program

    Get PDF
    Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability tests/in industrial gas turbine engines. A regenerator core made from aluminum silicate shows minimal evidence of chemical attack damage after 7804 hours of engine test at 800 C and another showed little distress after 4983 hours at 982 C. The results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included

    Development of the evaluation system for automobile remanufacturing

    Get PDF
    By 2015, the EU directives required the automobile manufacturers to produce a vehicle that contains reusable and / or recoverable parts at least 95% of total weight. In the developed countries, the legislative issue the take – back policy which requires the manufacturers to consider the end – of – life (EOL) of their products at early design stage. The goal of this paper is to propose a framework of development methodology that focuses on integrated design for remanufacturing evaluation system. This system supports the automobile product design and development at the early design phase. The proposed method is divided into two phases. The first phase aims to identify the suitable EOL process. The second phase aims to verify the most economical EOL process. The proposed method incorporates the Case base Reasoning [CBR] into the remanufacturing techniques. It is expected that the proposed method can provide the EOL with decision support during designing the automobile parts at the early design stage

    TmaDB: a repository for tissue microarray data

    Get PDF
    Background: Tissue microarray (TMA) technology has been developed to facilitate large, genome-scale molecular pathology studies. This technique provides a high-throughput method for analyzing a large cohort of clinical specimens in a single experiment thereby permitting the parallel analysis of molecular alterations ( at the DNA, RNA, or protein level) in thousands of tissue specimens. As a vast quantity of data can be generated in a single TMA experiment a systematic approach is required for the storage and analysis of such data. Description: To analyse TMA output a relational database ( known as TmaDB) has been developed to collate all aspects of information relating to TMAs. These data include the TMA construction protocol, experimental protocol and results from the various immunocytological and histochemical staining experiments including the scanned images for each of the TMA cores. Furthermore the database contains pathological information associated with each of the specimens on the TMA slide, the location of the various TMAs and the individual specimen blocks ( from which cores were taken) in the laboratory and their current status i.e. if they can be sectioned into further slides or if they are exhausted. TmaDB has been designed to incorporate and extend many of the published common data elements and the XML format for TMA experiments and is therefore compatible with the TMA data exchange specifications developed by the Association for Pathology Informatics community. Finally the design of the database is made flexible such that TMA experiments from several types of cancer can be stored in a single database, which incorporates the national minimum data set required for pathology reports supported by the Royal College of Pathologists (UK). Conclusion: TmaDB will provide a comprehensive repository for TMA data such that a large number of results from the numerous immunostaining experiments can be efficiently compared for each of the TMA cores. This will allow a systematic, large-scale comparison of tumour samples to facilitate the identification of gene products of clinical importance such as therapeutic or prognostic markers. In addition this work will contribute to the establishment of a standard for reporting TMA data analogous to MIAME in the description of microarray dat

    Ceramic regenerator systems development program

    Get PDF
    The DOE/NASA Ceramic Regenerator Design and Reliability Program aims to develop ceramic regenerator cores that can be used in passenger car and industrial/truck gas turbine engines. The major cause of failure of early gas turbine regenerators was found to be chemical attack of the ceramic material. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability test in Ford 707 industrial gas turbine engines late in 1974. Results of 53,065 hours of turbine engine durability testing are described. Two materials, aluminum silicate and magnesium aluminum silicate, show promise. Five aluminum silicate cores attained the durability objective of 10,000 hours at 800 C (1472 F). Another aluminum silicate core shows minimal evidence of chemical attack after 8071 hours at 982 C (1800 F). Results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are included
    corecore